.

Signal Conditioner

Universal signal conditioner is used in industrial process control systems. Isolated signal conditionerconnects industrial field instruments and control systems to complete the function of signal matching and conversion. Through reliable isolation technology, the signal conditioning equipmentresists various interference attacks and ensures the stability of the system and instruments in a complex electromagnetic environment. The isolated pt 100 signal conditioner of Chenzhuusing special design achieves anti-interference among power supply, input, and output. At the same time, the signal conditioning module/unit has a strong EMC performance that can work normally even under strong interference.

So far, our signal conditioning isolationamplifier for electronics, as a member of the whole safety automation system, has been applied to tens of thousands of industrial sites. And the stability of the control system escort, possessing the most complete models, has reached the international level. As one of the most professional signal isolator suppliers, Chenzhu promises to provide you good transducer signal conditioning and services! Different types of signal conditionersfor circuits can be offered by us, whether it's based on RTD loop powered digital isolator or DC Pt100 signal splitter, Pt100 signal conditionerwith 4-20mA output current. If you want to know the price of our 5v to 24v PLC signal converter, please contact us as soon as possible. Related sensors and signal conditioning pdf files are also available for you to refer to.

What is the difference between 2-wire transmitter, 3-wire transmitter and 4-wire transmitter?

 2-wire transmitter

 3-wire transmitter

 4-wire transmitter

Four-wire transmitters have their own internal power supply, and they do not need to be connected to a DC power supply. It has two power cords and two current output lines. The output of a 4-wire transmitter is usually a current signal.

FAQ of Signal Isolators

Q

How to distinguish between the active and passive signals?

A

According to whether the signal acquisition loop needs an external power supply,

Active signal:In the 4~20mA signal acquisition loop, the signal generating end has its own voltage drive and no external power supply equipment is needed. This 4~20mA is an active signal. Generally, 4-wire transmitter and 3-wire transmitter output active signals.

Passive signal:In the 4~20mA signal acquisition loop, the signal generating end does not have its own voltage drive and external power supply equipment is needed. This 4~20mA is a passive signal. Generally, a 2 wire temperature transmitter outputs passive signals.

Method of judging whether the external power supply is needed in the signal acquisition loop:

Disconnect the signal acquisition loop, and connect a voltmeter to the two lines of the field device (voltage transmitter). If there is voltage, it means the field device outputs active signals. If there is no voltage, it means the field device outputs passive signals.

Q

Temperature Input Signal Type and Range



Отправить запрос, связаться с поставщиком

Кому: Shanghai Chenzhu Instrument Co., Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Safety Relay
Safety Relay Safety Relay Automation direct safety monitering relays are mainly applied to the safety control circuit, connecting the safety sensing elements a...
T series DC Power SPD
T series DC Power SPD Like all outdoor buildings, photovoltaic devices are vulnerable to lightning strikes. By far the biggest culprit for the power surges that damage s...
DO Signal (SIS) Input 24V DC 5A Safety Relay
DO Signal (SIS) Input 24V DC 5A Safety Relay DO SISSignalInput 24V DC 5A Safety Relay These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS,...
Intrinsic Isolated Barrier
Intrinsic Isolated Barrier Intrinsic safety barriers and isolatorsuse intrinsically safe explosion-proof and functional safety technologies and adopts various measures such a...
40KA AC Power SPD
40KA AC Power SPD 40KA AC Power SPD SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 20kA/phase, Imax: 40kA/phase; hot-pluggable; fault indication ...
Все товары поставщика

Похожие товары

Wiring Harness Connector
Wiring Harness Connector Продавец: Aupins Technology Co., Ltd Connector plugs are used as electromechanical components to connect electrical circuits. AP team ...
SAE J1772 Charging Connector
SAE J1772 Charging Connector Продавец: Aupins Technology Co., Ltd AP SAE J1772AC EV charging plug conforms to SAE J1772provisions and requirements. It is compatibl...
IEC 62196-2 Charging Connector
IEC 62196-2 Charging Connector Продавец: Aupins Technology Co., Ltd AP IEC AC charging plugs conform to IEC 62196-2 2-llb provisions and requirements. It is compatib...
Hyperboloid Contacts
Hyperboloid Contacts Продавец: Aupins Technology Co., Ltd The hyperboloid contactsspring terminal is the patented product specially developed and researche...
GB/T Charging Connector
GB/T Charging Connector Продавец: Aupins Technology Co., Ltd GB/T Charging Connector is widely used in the AC charging system of electric vehicles and conform...