Femoral Stem Fatigue Performance Testing Machine

Standard

YY/T 0809.4 (China): Specifies fatigue testing protocols for femoral stems in partial/total hip arthroplasty.

ISO 7206-4 (International): Defines methodologies for evaluating the fatigue strength of femoral stem-bone cement interfaces.

ASTM F2580: Additional compliance for impact resistance testing of modular femoral necks.

Adaptive Protocols: Customizable for emerging standards in additive-manufactured implant evaluation.

Product Advantages

Electromagnetic Precision: M-Series actuator delivers ±0.05% force accuracy with 0.001N resolution.

5 Million Cycle Endurance: Proven capability to complete ISO 7206-4’s 5×10⁶-cycle fatigue test without drift.

R=0.1 Load Control: Advanced closed-loop system maintains stress ratios during dynamic loading.

Real-Time Fracture Detection: AI-powered acoustic emission monitoring identifies micro-cracks at sub-millisecond intervals.

Intuitive Workflow: 21.5” capacitive touchscreen with gesture control and pre-loaded SOPs for 15+ implant geometries.

Modular Environmental Chambers: Quick-swap pods for simulated physiological (-20°C to +50°C) and corrosive environment testing.

Product Features

Electromagnetic Actuator: 2.300 N peak force capacity with programmable load ratios (R=0.1–10).

Triaxial Loading System: Simultaneous axial/torsional/shear loading (50 Nm max torque).

Dynamic Load Control: 1–30 Hz frequency range with programmable waveforms (sine, square, random, custom).

Thermal-Mechanical Chamber: ±0.3°C temperature stability with integrated humidity control (10–95% RH).

High-Speed Imaging Ready: Syncs with external cameras for full-field strain mapping (DIC optional upgrade).

Safety First: Triple-redundant emergency stop, overload clutches, and laser-based specimen breakage detection.

Technical Parameters

ParameterSpecification
Max. Dynamic Force ±2.300 N (5.000 N peak optional)
Frequency Range 1–30 Hz (0.1 Hz increments)
Load Ratio (R) 0.1–10 (adjustable)
Axial Displacement ±15 mm (0.1 μm resolution)
Torque Capacity ±50 Nm (0.01 Nm resolution)
Temperature Range -20°C to +50°C (environmental chamber)
Humidity Control 10–95% RH (non-condensing)
Data Sampling Rate 100 kHz (synchronized across 16 channels)
Power Requirements 220V/110V ±10%, 50/60Hz, 2.000W
Dimensions (W×D×H) 1.500 × 1.000 × 2.200 mm
Weight 750 kg (including environmental chamber)
Noise Level <68 dB (A-weighted)

Standard Accessories

Femoral Stem Test Fixture Kit:

Self-centering collet system (12/14 mm taper compatibility)

Laser-aligned loading anvils with diamond-like carbon (DLC) coating

Thermal-Mechanical Chamber:

25L capacity with rapid cooling/heating (15°C/min)

316L stainless steel interior with HEPA filtration

TestMaster Ultimate Software:

Automated fatigue life prediction (S-N/ε-N curve generation)

21 CFR Part 11-compliant audit trail with blockchain timestamping

Remote monitoring via dedicated iOS/Android app

Operator Kit:

Calibrated torque wrench set (0.5–50 Nm)

Specimen alignment gauges (ISO 7206-4 compliant)

Calibration Bundle:

NIST-traceable force calibration weights

Temperature/humidity verification probe

Safety Kit:

Laser safety curtains

Acoustic enclosure with 30 dB noise reduction


Отправить запрос, связаться с поставщиком

Кому: Qinsun Instruments Co., LTD
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Battery Electrode Resistance Tester
Battery Electrode Resistance Tester Standard ASTM B193: Standard Test Method for Resistivity of Electrical Conductor Materials ISO 18516: Conductive Coatings – Measurement o...
Automatic freezing point pour point cold tester
Automatic freezing point pour point cold tester Product Introduction: The automatic freezing point pouring point Freezing point tester is suitable for petroleum, biological, chemical and other f...
Carpet hair removal measurement tester
Carpet hair removal measurement tester Standard ASTM D5417(Standard Test Method for Quantifying Loss of Fiber from Carpets) ISO 10362(Textile Floor Coverings - Determination of Fiber...
Paper folding tester
Paper folding tester Test principle The machine uses the motor drive screw to move the fixture. The test fixture is placed between the upper and lower sets, and then p...
Low Temperature Chrysler Fold Tester
Low Temperature Chrysler Fold Tester Standards: LP-463-KB-28-01 Method A Applications: This Cold Fold Tester is applied to the cold fold test based on Chrysler method and designed t...
Все товары поставщика

Похожие товары

FH-77 Dissolved hydrogen meter
FH-77 Dissolved hydrogen meter Продавец: Коллирон электроникс лимитед Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy...
Xenon Arc Weather Ometer
Xenon Arc Weather Ometer Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ...
Xenotest | Light Fastness Tester Si220 (SunTest)
Xenotest | Light Fastness Tester Si220 (SunTest) Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ...
Ozone Aging Chamber
Ozone Aging Chamber Продавец: Standard Group (Hong Kong) Limited Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum...
Plastic Smoke Density Tester F313
Plastic Smoke Density Tester F313 Продавец: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The F313 Plastic Smoke Density Tester is ...