Initial Adhesion Tester
The initial - tack tester, also known as the initial - tack property tester or adhesive tape tackiness tester, is an instrument specifically used to measure the initial tackiness of materials. The following is a detailed description of its main uses, compliance standards, and technical parameters:
I. Main Uses
The initial - tack tester is mainly used to test the initial tackiness of products such as adhesive tapes, medical patches, self - adhesive labels, and protective films. By simulating the actual use environment of adhesion, it tests the adhesive performance of these products when they are in brief contact with the adhesive surface under slight pressure. This device is widely used in multiple industries, including packaging, adhesives, printing, and pharmaceuticals, providing important data for product performance evaluation, quality control, and research and development. Specifically: - Packaging Industry: It is used to test the adhesive performance of adhesive tapes, carton - sealing adhesives, etc., ensuring the integrity of packaging during transportation. - Adhesive Industry: It is used for research and development and quality control. By testing the initial tackiness of different adhesives under various conditions, it provides data support for the development of new adhesives. - Printing Industry: It tests the tackiness of printing labels, such as trademarks and colored labels on self - adhesive labels, ensuring the reliability and durability of label products. - Pharmaceutical Industry: It tests the initial tackiness of adhesive materials in pharmaceutical packaging and medical plasters, ensuring the effectiveness of products and the medication experience of patients. In addition, the initial - tack tester can also be used to test the initial tackiness of office supplies such as sticky notes, and to evaluate the force required for the label to separate from the test substrate.
II. Compliance Standards
- GB 4852 Test Method for Initial Tackiness of Pressure - Sensitive Adhesive Tapes (Rolling Ball Method) - JIS Z0237 (Japanese Industrial Standard) and other related standards
III. Technical Parameters
- Testing Principle: Adopting the inclined - plane rolling - ball method. When a slight pressure causes a brief contact between the steel ball and the adhesive surface of the test specimen, the adhesion of products like adhesive tapes or labels to the steel ball is used to test the initial tackiness of the specimen. - Adjustable Inclination Angle: The testing inclination angle can be freely adjusted within the range of 0 - 60° according to users' needs to adapt to the testing requirements of different products. - Tabletop Width: Usually about 120mm to ensure there is enough space to place the test specimen. - Test Area Width: Generally about 80mm, providing a sufficient operational area for the test. - Standard Steel Balls: The size range is usually from 1/32 inch to 1 inch. Steel balls of different sizes are used to test products with different adhesive forces. - External Dimensions: Vary depending on the equipment and model. Generally, the length is between 300 - 450mm, the width is between 120 - 160mm, and the height is between 150 - 200mm. - Weight: Also varies depending on the model and brand. Generally, it does not exceed 10kg, making it easy to move and place.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Socks Abrasion/Wear Resistance Tester (for Socks wear tester) | Product Introduction: Socks wear tester is a special equipment, mainly used to test the wear resistance of socks material. It evaluates the comfor... | |
| Wear Resistance Tester for Total Hip Joint Prostheses | Standard YY/T 0651.1-2016 (China): Specifies wear testing parameters for total hip prostheses, including angular motion, loading modes, and enviro... | |
| Medical injection needle rigidity tester | Standard GB 18457-2001 This standard mandates precise control over needle wall thickness (normal, thin, ultra-thin) and rigidity performance, dir... | |
| Coatings Shear Fatigue Tester | Standard YY/T 0988.13-2017 (China): Specifies shear fatigue testing protocols for coatings on metallic substrates, including load ratios, frequenc... | |
| " Helmet Goggles High Speed Particle Impact Testing Machine" | Main Purpose To test the impact - resistance performance of glasses, goggles and face shields at a certain speed. Applicable Standards SNELL S... |
Похожие товары
| FH-77 Dissolved hydrogen meter | Продавец: Коллирон электроникс лимитед | Pen type dissolved hydrogen detector / dissolved hydrogen meter: used to measure the dissolved hy... | |
| Xenon Arc Weather Ometer | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App: +86 181 0160 0864 SI4000Xenon Arc Weather Ometer utilizes a xenon lamp ... | |
| Xenotest | Light Fastness Tester Si220 (SunTest) | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 180 0160 0864 A Light Fastness Tester, or Xenon Tester, Accelerated ... | |
| Ozone Aging Chamber | Продавец: Standard Group (Hong Kong) Limited | Get a quote: Whats/App:+86 156 1874 6768 The Ozone Aging Chamber is a precision testing instrum... | |
| Plastic Smoke Density Tester F313 | Продавец: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The F313 Plastic Smoke Density Tester is ... |