HM-200 Hygronom

Overview

Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, it converts wet gas concentration into dry gas concentration. In addition, it also can be used in industrial online humidity monitoring.

HM-200 hygronom is aprecision humidity meter, which employs microprocessor as the core, and frequency conversion icon oxygen sensor as a measuring unit. The installation method adopts a heat tracing pipeline installation. It is a self-developed product, of which, the core component is from Switzerland.

Under the effect of the air pump, the flue gas inside the stack enters the measurement module after heating from the heat tracing probe. The whole process of extraction, measurement, and discharge is with heat tracing to prevent gas from condensation, which will affect the measurement of moisture in the flue gas. The flue gas enters the measurement module after heating and the frequency conversion icon oxygen sensor will start to measure gas concentration. After the measurement, the gas can get into an analyzer for the measurement of other components.

Features Technical Parameter Application

Features Of HM-200 Hygronom

nPortable structure, easy to install and disassemble

nAble to measure the humidity of 300℃ flue gas

nAble to match with the large-scale system for measurement or independent measurement

nThe probe is equipped with heat tracing function to prevent condensate water from damaging probe and affecting measuring value

nImported core components with high-performance index and reliability

Technical Parameter Of HM-200 Hygronom

Measurement range

O2: 0~25.00%, H2O: 0~40.00% (volume ratio )

Sensor

Frequency conversion icon oxygen sensor (2)

Accuracy

0~1% O2:±1.5%F.S.

0~25% O2:±1.5% of measured value

0~40.00% H2O:±1%F.S.

Stability

0~1% O2:±1.5%F.S./7d

0~25% O2:±1.5%/7d of measured value

0~40.00% H2O:±1%F.S./7d

Response time

T90<30s

Sensor life

>2 years (under normal use)

Transmitter life

>5 years (under normal use)

Power supply

24VDC

Instrument weight

Net weight about 2.25kg (include operation panel)

Ambient temperature

Transmitter: -10°C~+50°C

Probe: 0~300℃ (except probe cable)

Ambient humidity

<85%RH

Power consumption

Maximum about 35VA (heating)

Under normal working: 30~31W

Sample gas flow

(2~6)L/min

Analog output (2 sets)

Settable 4-20mA, 0-20mA, 0-1-5-10V, 1-5V

Communication

Rs485 (standard)/RS232 (optional)

Application Of HM-200 Hygronom

It can be widely applied in high-temperature (300℃) gas (such as desulfuration and denitration) humidity measurement of Continuous Emission Monitoring System (CEMS), humidity measurement and control in fields including wood, building material, papermaking, chemical industry, fiber, pharmacy, textile, tobacco, vegetable and food processing.



Отправить запрос, связаться с поставщиком

Кому: Ханчжоу Zetian Technology Co., Ltd.
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

ERMS-2000-M Mobile Vehicle Exhaust Telemetry System
ERMS-2000-M Mobile Vehicle Exhaust Telemetry System Overview The ERMS2000-M movable vehicle exhaust remote sensing system, developed by our company, is suitable for mobile enforcement of city roads a...
Water Quality Analyzers
Water Quality Analyzers Hangzhou Zetian Technology Co., Ltd. is the only water analysis equipment manufacturer in China that has five analytical technology platforms inclu...
AM-5100 SO2 Analyzer
AM-5100 SO2 Analyzer Are you looking for air analyzer equipment? Overview AM-5100 SO2 air pollution analyzeradopts ultraviolet fluorescence technique and combines advan...
HM-100 High-temperature Hygronom
HM-100 High-temperature Hygronom Overview Hygronom is also called gas moisture meteror dew-point meter, which is used to measure the humidity of flue gas emitted by pollution sourc...
FT-2000P Portable FTIR Gas Analyzer
FT-2000P Portable FTIR Gas Analyzer Overview Based on FTIR technology, FT-2000P portable gas analyzer can continuously monitor various kinds of components in the emission, such as SO2...
Все товары поставщика

Похожие товары

GF302D1 PORTABLE THREE-PHASE kWH METER TEST DEVICE
GF302D1 PORTABLE THREE-PHASE kWH METER TEST DEVICE Продавец: 782364 GF302D1便携式三相电能表测试装置是一种误差测量仪器。GF302D1 具有 0.05% 的高精度、便携设计和对环境的高耐受性。特点: 1.量程:电压:0-500V;电流:0-120A;2.可...
WDet-7000 Integration Water Quality Online Analyzer
WDet-7000 Integration Water Quality Online Analyzer Продавец: Ханчжоу Zetian Technology Co., Ltd. WDet-7000 multi parameter water analyzeris a high-level integration of a multi parameter water an...
WDet-5000UVI Immersion UV Water Analyzer
WDet-5000UVI Immersion UV Water Analyzer Продавец: Ханчжоу Zetian Technology Co., Ltd. WDet-5000UVI is the first full-spectrum (200-800nm) immersion UV portable water quality analyzera...
WDet-5000TPN Total Nitrogen Online Automatic Analyzer
WDet-5000TPN Total Nitrogen Online Automatic Analyzer Продавец: Ханчжоу Zetian Technology Co., Ltd. WDet-5000TPN is a self-developed total nitrogen analyzer. This total nitrogen analyzer is based o...
WDet-5000 Total Phosphorus Online Automatic Analyzer
WDet-5000 Total Phosphorus Online Automatic Analyzer Продавец: Ханчжоу Zetian Technology Co., Ltd. WDet-5000 is a self-developed total phosphorus on-line monitoring instrument. This total phosphor...