DMS-100/MS-1000 Dust Monitor
HANGZHOU ZETIAN TECHNOLOGY CO., LTDwas established in 2008, and as a fast-growing company specialized in environmental pollution monitoring and industrial process control, ZETIAN’s instruments and emission analyzers can provide you best solutions.
Overview Of DMS-100/MS-1000
DMS-100/MS-1000 is a self-developed online dust analysis product and a dust particle measuring device, adopting laser backward scattering measuring technology with imported core components. The DMS-100/MS-1000 dust particle measuring device is mainly used for continuous monitoring of PM emission concentrations of various pollution sources. The DMS-100/MS-1000 dust particle measuring device can be not only matched with CEMS continuous emission monitoring systembut also be used separately or together with multiple dust monitors to form a dust monitoring network, sharing the same data collection and processing background.
The DMS-100/MS-1000 dust particle measuring device is widely applied in enterprises including thermal power, ferrous metallurgy, petrochemical industry, cement production, potting, waste incineration; flue gas emission monitoring in all kinds of power generating boiler, industrial kiln, and industrial boiler; monitoring and control in gas desulphurization and dust removal process.
Principle Of DMS-100/MS-1000 Dust Monitor
The dms 100/MS-1000 dust particle measuring device consists of the optical part, circuit and signal processing part, calibrator and air curtain protection part.
The laser beam (650nm) emitted by semiconductor laser enters the stack and produces scattering light by interaction with dust particles. The backscattered light of the DMS-100/MS-1000 dust particle measuring device enters the photosensitive detector through the convergence of the lens. The signal processing circuit converts the light signal into a standard signal in proportion to dust concentration and output, thus dust particle emission concentration of pollution source is obtained.
Features Of DMS-100/MS-1000 Dust Monitor
• The DMS-100/MS-1000 dust particle measuring device supports online zero and span calibration and meets dust monitor principle
• The DMS-100/MS-1000 dust particle measuring device has automatic gain control function and temperature compensation
• The DMS-100/MS-1000 dust particle measuring device is convenient for installation, disassembly and cleaning with small and compact structure
• The DMS-100/MS-1000 dust particle measuring device is able to eliminate the influence of background stray light
Specification Of DMS-100/MS-1000 Dust Monitor
|
Measuring principle |
Laser backward scattering |
|
Measuring range |
0~200mg/m3, 0~10g/m3 (customizable) |
|
Indication error |
≤±20% |
|
Indication repeatability |
10% |
|
Laser device |
650nm |
|
Medium temperature |
<300℃ |
|
Ambient Temperature |
-20~+45℃ |
|
Stack diameter |
≥0.5m |
|
Analog output |
4-20mA, maximum load 800Ω |
|
COMM interface |
Rs485, 2 ×relay output, bluetooth |
|
HMI |
IPC, APP(for MS-1000) |
|
Weight |
4kg |
|
Power |
<3W |
|
Dimension |
158mm* 158mm*234mm (square) |
|
158mm* 158mm*273mm (circular) |
|
|
Supply voltage |
24VDC±10% |
Installation Of DMS-100/MS-1000 Dust Monitor1.TheDMS-100/MS-1000dust particle measuring deviceis installed on the stack by flange2. The rain cover oftheDMS-100/MS-1000dust particle measuring devicewill be installed at the back end of the monitor3. Power and gas source is connected at the back end oftheDMS-100/MS-1000dust particle measuring device
Send product request
Other supplier products
| FT-2000P Portable FTIR Gas Analyzer | Overview Based on FTIR technology, FT-2000P portable gas analyzer can continuously monitor various kinds of components in the emission, such as SO2... | |
| EM-5P Portable Flue Gas Analyzer | Overview EM-5P portable gas monitoring system mainly consists of gas monitoring sensors (SO2, NOx, CO, CO2), sample conditioning unit, sampling uni... | |
| HM-100 High-temperature Hygronom | Overview Hygronom is also called moisture meter or dew-point meter, which is used to measure the humidity of flue gas emitted by pollution source. ... | |
| HM-200 Hygronom | Overview Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, the precision humidity ... | |
| WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer | Overview Of WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer Wastewater WDet-5000 is a self-developed ammoniacal nitrogen water qualityonline ... |
Same products
| Fourteen-lmpeller paddle wheel aerator | Seller: Taizhou Jinhu Mechanical & Electrical Co., Ltd. | The Fourteen-Impeller Paddle Wheel Aerator from Taizhou Jinhu Mechanical & Electrical Co., Lt... | |
| Double Station CNC Tube End Shrinking Machine | Seller: Yongkang Hubang Machinery Technology Co., Ltd. | Yongkang Hubang Machinery Technology Co., Ltd. provides the Double Station CNC Tube End Shrinking... | |
| Super Impeller aerator (water- cooled motor) | Seller: Taizhou Jinhu Mechanical & Electrical Co., Ltd. | Taizhou Jinhu Mechanical & Electrical Co., Ltd. offers the Super Impeller Aerator (Water-Cool... | |
| Water Bulging Bottle Making Machine | Seller: Yongkang Hubang Machinery Technology Co., Ltd. | Yongkang Hubang Machinery Technology Co., Ltd. specializes in machinery for thermos and bottle ma... | |
| TC SERIES 180-210 HP TRACTOR | Seller: TIANJIN TRACTOR MANUFACTURING CO., LTD | Our company has long specialized in the development of high-horsepower wheeled tractors. This par... |