DMS-100/MS-1000 Dust Monitor
HANGZHOU ZETIAN TECHNOLOGY CO., LTDwas established in 2008, and as a fast-growing company specialized in environmental pollution monitoring and industrial process control, ZETIAN’s instruments and emission analyzers can provide you best solutions.
Overview Of DMS-100/MS-1000
DMS-100/MS-1000 is a self-developed online dust analysis product and a dust particle measuring device, adopting laser backward scattering measuring technology with imported core components. The DMS-100/MS-1000 dust particle measuring device is mainly used for continuous monitoring of PM emission concentrations of various pollution sources. The DMS-100/MS-1000 dust particle measuring device can be not only matched with CEMS continuous emission monitoring systembut also be used separately or together with multiple dust monitors to form a dust monitoring network, sharing the same data collection and processing background.
The DMS-100/MS-1000 dust particle measuring device is widely applied in enterprises including thermal power, ferrous metallurgy, petrochemical industry, cement production, potting, waste incineration; flue gas emission monitoring in all kinds of power generating boiler, industrial kiln, and industrial boiler; monitoring and control in gas desulphurization and dust removal process.
Principle Of DMS-100/MS-1000 Dust Monitor
The dms 100/MS-1000 dust particle measuring device consists of the optical part, circuit and signal processing part, calibrator and air curtain protection part.
The laser beam (650nm) emitted by semiconductor laser enters the stack and produces scattering light by interaction with dust particles. The backscattered light of the DMS-100/MS-1000 dust particle measuring device enters the photosensitive detector through the convergence of the lens. The signal processing circuit converts the light signal into a standard signal in proportion to dust concentration and output, thus dust particle emission concentration of pollution source is obtained.
Features Of DMS-100/MS-1000 Dust Monitor
• The DMS-100/MS-1000 dust particle measuring device supports online zero and span calibration and meets dust monitor principle
• The DMS-100/MS-1000 dust particle measuring device has automatic gain control function and temperature compensation
• The DMS-100/MS-1000 dust particle measuring device is convenient for installation, disassembly and cleaning with small and compact structure
• The DMS-100/MS-1000 dust particle measuring device is able to eliminate the influence of background stray light
Specification Of DMS-100/MS-1000 Dust Monitor
|
Measuring principle |
Laser backward scattering |
|
Measuring range |
0~200mg/m3, 0~10g/m3 (customizable) |
|
Indication error |
≤±20% |
|
Indication repeatability |
10% |
|
Laser device |
650nm |
|
Medium temperature |
<300℃ |
|
Ambient Temperature |
-20~+45℃ |
|
Stack diameter |
≥0.5m |
|
Analog output |
4-20mA, maximum load 800Ω |
|
COMM interface |
Rs485, 2 ×relay output, bluetooth |
|
HMI |
IPC, APP(for MS-1000) |
|
Weight |
4kg |
|
Power |
<3W |
|
Dimension |
158mm* 158mm*234mm (square) |
|
158mm* 158mm*273mm (circular) |
|
|
Supply voltage |
24VDC±10% |
Installation Of DMS-100/MS-1000 Dust Monitor1.TheDMS-100/MS-1000dust particle measuring deviceis installed on the stack by flange2. The rain cover oftheDMS-100/MS-1000dust particle measuring devicewill be installed at the back end of the monitor3. Power and gas source is connected at the back end oftheDMS-100/MS-1000dust particle measuring device
在线联系供应商
Other supplier products
| Water Quality Analyzers | HANGZHOU ZETIAN TECHNOLOGY CO., LTDwas established in 2008, and has national wide impact in China now as a fast-growing company specialized in env... | |
| Vehicle Exhaust Remote Sensing System | The car emissions test equipmenthas attracted more and more people's attention and attention because of its advantages of speed, convenience, and w... | |
| EM-5P Portable Flue Gas Analyzer | Overview EM-5P portable gas monitoring system mainly consists of gas monitoring sensors (SO2, NOx, CO, CO2), sample conditioning unit, sampling uni... | |
| HM-200 Hygronom | Overview Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, it converts wet gas con... | |
| FT-3000 FTIR Gas Analyzer | HANGZHOU CHUNLAI (ZETIAN) TECHNOLOGY was established in 2008, and has national wide impact in China now as a fast-growing company specialized in en... |
Same products
| Intelligent Precision Glue Control System | 卖方: 855005 | Intelligent Precision Glue Control System The Golden Horse GM-4020 is an intelligent glue concen... | |
| JM-5416D Automatic Rigid Box Making Machine | 卖方: 855005 | JM-5416D Automatic Rigid Box Making Machine The JM-5416Dintelligent visual fully automatic box m... | |
| Positioning Machine JM-600B | 卖方: 855005 | Positioning Machine JM-600B The vision positioning machineis the core component for producing li... | |
| Automatic Feida Gluing Machine JM-600A | 卖方: 855005 | Automatic Feida Gluing Machine JM-600A Automatic Gluing Machineis used for gluing the cover pape... | |
| Automatic Grooving Machine JM-1200 | 卖方: 855005 | Automatic Grooving Machine JM-1200 The JM-1200 Automatic Cross Grooving Machineis capable of bid... |