FOTECTOR SERIES AUTOMATED SOLID PHASE EXTRACTION SYSTEMS
RayKol's Fotector series Automated Solid Phase Extraction Systems are automated SPE systems and purification equipments, designed to meet the requirements of large-scale sample preparation in modern testing laboratories. It moderates the workflow bottleneck of manual operation with precise flow rate control and repeat processing. Compact instrument design, good fit in a fume hood, minimize chemical exposure and contact lab technicians. Fotector series automated solid phase extraction systemcan be widely used in any pre-treatment of the large sample size required solid-phase extraction, such as pesticide and veterinary drug residues in food, harmful organic compounds in the environment, poisonous materials in blood and urine.
FEATURES OF FOTECTOR SERIES AUTOMATED SOLID PHASE EXTRACTION SYSTEMS
Fully automated solid-phase extraction, minimal operator intervention
Accurate flow rate control to ensure parallelism
Multiple extraction channels, consistent batch processing
Efficient operation mode through sychronous rack positioning and fast solvent switch
Flexible operation with various modules for different applications
Graphical software interface, remote real-time monitoring
SPECIFICATIONS OF FOTECTOR SERIES AUTOMATED SOLID PHASE EXTRACTION SYSTEMS
|
Parameter |
Specification |
|||
|
Product |
Fotector 02HT |
Fotector Plus |
Fotector 08HT |
FS 360 |
|
Extraction channel |
2 channels in parallel |
6 channels in parallel |
8 channels in parallel |
6 channels in parallel |
|
Sample capacity |
20, 12 |
60, 36 |
80, 48 |
36 |
|
SPE cartridge size |
3mL, 6mL |
1mL, 3mL, 6mL, 12mL, 20mL |
1mL, 3mL, 6mL |
3mL, 6mL, 12mL |
|
Sample vials |
15mL, 20mL, 60mL, 80mL |
15mL, 20mL, 60mL, 80mL |
15mL, 20mL, 60mL, 80mL |
15mL, 20mL, 80mL |
|
Collection vials |
15mL, 20mL, 60mL, 80mL |
15mL, 20mL, 60mL, 80mL |
15mL, 20mL, 60mL, 80mL |
15mL, 20mL, 80mL |
|
Solvent capacity |
8 |
8 |
8 |
8 |
|
Flow rate |
||||
|
Gas supply and connection |
Nitrogen gas; |
Nitrogen gas; |
Nitrogen gas; |
Nitrogen gas; |
|
Output: 0 to 20psi/1.4bar |
Output: 0 to 20psi/1.4bar |
Output: 0 to 20psi/1.4bar |
Output: 0 to 20psi/1.4bar |
|
|
Fume hood/ventilation |
Required |
Required |
Required |
Required |
|
Control software |
Windows PC; WIFI connection |
Windows PC; WIFI connection |
Windows PC; WIFI connection |
Windows PC; WIFI connection |
|
Dimension |
40cm x 38cm x 58cm |
62cm x 38cm x 63cm |
77cm x 45cm x 64cm |
62cm x 38cm x 63cm |
|
Weight |
30kg |
68kg |
72kg |
68kg |
|
Power supply |
200 to 240V, 50/60Hz |
200 to 240V, 50/60Hz |
200 to 240V, 50/60Hz |
200 to 240V, 50/60Hz |
|
Storage temperature |
0 to 40°C |
0 to 40°C |
0 to 40°C |
0 to 40°C |
|
Storage humidity |
20 to 85% |
20 to 85% |
20 to 85% |
20 to 85% |
|
Operating temperature |
10 to 40°C |
10 to 40°C |
10 to 40°C |
10 to 40°C |
|
Operating humidity |
20 to 80% |
20 to 80% |
20 to 80% |
20 to 80% |
RayKolGroup is dedicated to research&development and manufacture of automated laboratory systems. With systematic framework and integrated development of RayKol own corelaboratory automation systems technologies, combined features of robot and artificial intelligence and coordination of hardware and lab automation software, we provide a wide range of automated sample preparation systems, integrated systems and consumables for analytical laboratories and life science laboratories, centred on the fields of food safety, environment protection and life science.
Send product request
Other supplier products
| SPE CARTRIDGES | RayCure SPE series provides high-quality SPE cartridgesfor various types of solid phase extraction, including manifold, vacuum as well as automated... | |
| RAYCURE SPE COLUMNS | RayCure SPE series provide pre-packed SPE columnswith a variety of sorbents, resins and cartridge size for various methods and target analytes. The... | |
| MICROWAVE DIGESTION | Microwave assisted digestionutilizes the penetrability and activation reaction ability of the microwave to heat the reagents and samples in the sea... | |
| BLOCK DIGESTION | RayKol block digestion systemutilizes graphite block to achieve encircled heating to completely digest samples based on the method of wet digestion... | |
| AUTO GDA SERIES AUTOMATED GRAPHITE DIGESTION SYSTEM | Raykol Auto GDA series Automated graphite digestersystem is designed based on wet digestion theory, it can automatically complete full digestion pr... |
Same products
| Casting Grinding Balls | Seller: 869376 | Casting Grinding Balls , so called as Casting Grinding media balls,casting grinding steel ba... | |
| KL‑98 Professional Laboratory pH/ORP/Temperature Tester | Seller: Kelilong Electron Co.,Ltd | Product Description: The PH‑98 meter is an easy‑to‑operate, multi‑functional microprocessor‑ba... | |
| KL‑98 Professional Laboratory pH/ORP/Temperature Tester | Seller: Kelilong Electron Co.,Ltd | Product Description: The PH‑98 meter is an easy‑to‑operate, multi‑functional microprocessor‑ba... | |
| LSAW Steel Pipe & Tube | Seller: HEBEI TIRICO PIPELINE CO.,LTD | LSAW Steel Pipe & Tube , or Longitudinal Submerged Arc-Welding Pipe (also known as SAWL ... | |
| Anti-Corrosion Steel Pipe & Tube | Seller: HEBEI TIRICO PIPELINE CO.,LTD | Anti-Corrosion Steel Pipe & Tube Anti-Corrosion Steel Pipe & Tube What Is an Anti... |