TNID Residual Current Circuit Breaker

Scope of Application
TNID-63 Residual Current Circuit Breaker is used for the circuit of AC 50Hz, rated voltage of 230V for 2 poles, 400V for 4 poles, rated current of 63A, when the personal electric shock or grid leakage current exceeds the specified value, the residual current action circuit breakers cut off the trouble power quickly to protect the personal and electrical equipment, it also can be applied to infrequent transfer and start of the circuit.
TNID-63 RCCB Circuit Breaker are applicable to industrial, commercial, high-rise and civil residence and other places.
Meet the standards: GB 16916.1, IEC 61008-1, obtain CCC, CE certification.

Normal operating conditions and installation conditions
The elevation of the installation site is not more than 2000m.
Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃.
Atmospheric conditions: Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. Consider the temperature changes in product on the surface of the gel and take special measures.
Pollution degree: 2
Installation conditions: Installed in the place without simpact vibration and invasion of rain and snow: the upper-terminal connects the power, the lower terminal connects load; the inclination of the vertical plane is not more than 2 °. Mounted on the TH35-7.5 steel rail.
Installation categories: Ⅱ, Ⅲ level.
The external magnetic field in the vicinity of the circuit breaker installation site does not exceed 5 times of the geomagnetic field in any direction.

Main parameters and technical performance
Rated voltage(V): 230V~(1P+N), 400V~(3P+N)
Rated curren(A): 25, 40, 63
Rated residual operating current(A): 0.03, 0.1, 0.3
Pole: 1P+N, 3P+N
Rated limiting short-circuit current Inc: 6000A
Rated limiting residual short-circuit current I△c: 6000A



在线联系供应商

至: 上海泰西电气有限公司
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

BK Industrial Control Transformer
BK Industrial Control Transformer Scope of Application BK Industrial Control Transformer is suitable for the AC circuit of 50Hz/60Hz, which is used as the control power, local light...
TXJQ3 Electrical Isolation Switch
TXJQ3 Electrical Isolation Switch Scope of Application TXJQ3 Electrical Isolation Switch is used for AC 50 / 60Hz, rated voltage 230-400V , 63A to 125A of rated current in the resis...
TXR1-700 Motor Soft Starter
TXR1-700 Motor Soft Starter Product Overview TXR1-700 Soft Starter for AC three phase Motor is a new start-up equipment which integrates electric force and electron techniqus,...
DZ47-125 Circuit Breaker
DZ47-125 Circuit Breaker Scope of Application DZ47-125 Miniature Circuit Breaker with protection of short circuit and overload, suitable for lighting and power distribution...
TNID Residual Current Circuit Breaker
TNID Residual Current Circuit Breaker Scope of ApplicationTNID-63 Residual Current Circuit Breaker is used for the circuit of AC 50Hz, rated voltage of 230V for 2 poles, 400V for 4 pole...
供应产品

Same products

LW34-12 10KV outdoor SF6 circuit breaker
LW34-12 10KV outdoor SF6 circuit breaker 卖方: Bokong Electric Co., Ltd Product Description LW34-12 10KV is a new outdoor high-voltage electrical arcing and SF6 gas a...
Consumer PCB
Consumer PCB 卖方: Xinfeng Huihe Circuits Co., Ltd. The size, thickness and weight of products in the consumer electronics field have been greatly re...
PCB Prototyping
PCB Prototyping 卖方: Xinfeng Huihe Circuits Co., Ltd. China high quality pcb prototypeFactory Has 97% On-Time Delivery Ratio In accordance with IPC st...
PCB Application
PCB Application 卖方: Xinfeng Huihe Circuits Co., Ltd. PCB Application As a leading PCB supplier in China printed circuit board industryincluding com...
PCB Board For Sale
PCB Board For Sale 卖方: Xinfeng Huihe Circuits Co., Ltd. With the help of a technology development team for professional printed circuit board manufacture...