mr current transformer
MRCurrenttransformerisaveryusefuldevice,itconvertshighACcurrenttosmalleasilymanageablevalue.If
currenttransformershavenobusbar,theyaremanufacturedwithoutprimarywinding.Insteadofthis,itispossibletoconstituteprimarywindingbypassingconductororbusbarinsidetorpidlycoreoftransformer.Furthermore,thesecondaryterminalsareunderatransparentsealablecovers.MRaremanufacturedintwotypesformeasuringandprotection.
Feature:
1.Theaccuracyclassisdesignedbythehighestpermissiblepercentagecurrent(ratio)errorattheratedcurrentperscribedfortheaccuracyclassconcerned.
2.TheElectronicTransformersthestandardsilliconsteelcoremodels,tapewrappingcurrenttransformer,lowcost.
3.Themeasuringcurrenttransformerscanbeusedwithorwithoutfootandplasticcover.
Application:
STANDARD:
IEC6044-1,EN60044-1,VDE0414-44-1,GB1208-2006
SPECIFICATION:
|
Primarycurrent: |
30A-5000A |
|
Secondarycurrent: |
5A,1A |
|
Standardapproval: |
IEC6044-1,EN60044-1,VDE0414-44-1,GB1208-2006 |
|
Maximumvoltage: |
|
|
Frequency: |
50/60Hz |
|
Ratedload: |
|
|
Class: |
|
|
Short-timethermalcurrent: |
Ith=60*ih |
|
Ratedsecuritycoefficient: |
FS<5 |
ElectricalParameter
RatedFrequency
50/60Hz
RatedTestVoltage
3KVAC(1MIN)
RatedInput
100A-300A
Placeofinstallation
Indoor
Ratedshort-timethermalcurrent(Ith)
60Ih
Class
Secondarycurrent
5A1A
Altitude
<1000m
Humidity
<80%
Ambienttemperature
-5℃~40℃
Operatingtemperature
-10℃~85℃
Housingself-extingshingclass
VO
Model
Nominalcurrentratio
Burden(VA)Accuracy
RatedVoltage(V)
RatedFrequency(Hz)
Class:0.5
Class1
MR-40
100/5A
720
50/60
150/5A
720
50/60
200/5A
720
50/60
250/5A
720
50/60
300/5A
720
50/60
在线联系供应商
Other supplier products
| 开口式电流互感器 | TheKCTrangeofsplitcorecurrenttransformershavebeenspecificallydesignedtobesmallandeasytoopenandyetmaintaintheaccuracyrequiredforkwhmeters.Thebenefit... | |
| 互感器 | ||
| small current transformer | MRCurrenttransformerisaveryusefuldevice,itconvertshighACcurrenttosmalleasilymanageablevalue.If currenttransformershavenobusbar,theyaremanufacturedw... | |
| SCT-19 cplit core current transformer | SCTseriesretro-fit(Split-core)currenttransformerhasbeenspeciallydesignedtofacilitatetheirinstallationinneworalreadyexistingnetworks.Theymaybeinstal... | |
| mr current transformer | MRCurrenttransformerisaveryusefuldevice,itconvertshighACcurrenttosmalleasilymanageablevalue.If currenttransformershavenobusbar,theyaremanufacturedw... |
Same products
| China factory Transformer bushing BRDW-126/630-3 for power station | 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD | "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel... | |
| TOROIDAL TRANSFORMER | 卖方: Yu Yang Magnetic Co., LTD | Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >... | |
| ACREL AID150 ALARM AND DISPLAY DEVICE | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
| ACREL ANSVG STATIC VAR GENERATOR | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
| The Working Principle of Active Power Filter | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... |