SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection. It is the ideal product for distribution systems and widely used in the subway, shipbuilding, mining, chemical, power companies and personnel-intensive buildings as well as other special requirements of the occasion for safety.
Model and Meaning
SC(B)10 Series Resin-insulated Dry Type Transformer
SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers
Technical Parameter for6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer
|
Rated capacity(KVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
|
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
|
30 |
±2X2.5%±5% |
Dyn11Yyn0 |
190 |
670 |
710 |
760 |
||||
|
50 |
270 |
940 |
1000 |
1070 |
||||||
|
80 |
370 |
1290 |
1380 |
1480 |
||||||
|
100 |
400 |
1480 |
1570 |
1690 |
||||||
|
125 |
470 |
1740 |
1850 |
1980 |
||||||
|
160 |
540 |
2000 |
2130 |
2280 |
||||||
|
200 |
±2X2.5%±5% |
620 |
2370 |
2530 |
2710 |
|||||
|
250 |
720 |
2590 |
2760 |
2960 |
||||||
|
315 |
880 |
3270 |
3470 |
3730 |
||||||
|
400 |
980 |
3750 |
3990 |
4280 |
||||||
|
500 |
1150 |
4590 |
4880 |
5230 |
||||||
|
630 |
1340 |
5530 |
5880 |
6290 |
||||||
|
630 |
1300 |
5610 |
5960 |
6400 |
||||||
|
800 |
1520 |
6550 |
6960 |
7460 |
||||||
|
1000 |
1770 |
7650 |
8130 |
8760 |
||||||
|
1250 |
2090 |
9100 |
9690 |
10300 |
||||||
|
1600 |
2450 |
11000 |
11700 |
12500 |
||||||
|
2000 |
3050 |
13600 |
14400 |
15500 |
||||||
|
2500 |
3600 |
16100 |
17100 |
18400 |
||||||
|
1600 |
2450 |
1220 |
12900 |
13900 |
||||||
|
2000 |
3050 |
15000 |
15900 |
17100 |
||||||
|
2500 |
3600 |
17700 |
18800 |
20200 |
||||||
Notes:The load losses listed in the table are the values of the reference temperature for different insulation systems inparentheses; The load losses under other insulation system temperatures that are not included in the table should be according to their respective reference temperatures, the corresponding calculation is based on the"- 155 ℃(F)" insulation system temperature data.
Notes:The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
Technical Parameter for20kV& 50kVA-2500kVA With Off CircuitDry Type Transformer
|
(KVA)Rated capacity |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
|
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
|
50 |
202224 |
±2.5%±5%±5%±2×2.5% |
Dyn11Yyn0 |
340 |
1160 |
1230 |
1310 |
|||
|
100 |
540 |
1870 |
1990 |
2130 |
||||||
|
160 |
2350 |
2470 |
3460 |
|||||||
|
200 |
±2X2.5%±5% |
730 |
2770 |
2940 |
3140 |
|||||
|
250 |
840 |
3220 |
3420 |
3660 |
||||||
|
315 |
970 |
3850 |
4080 |
4360 |
||||||
|
400 |
1150 |
4650 |
4840 |
5180 |
||||||
|
500 |
1350 |
5460 |
5790 |
6190 |
||||||
|
630 |
1530 |
6450 |
6840 |
7320 |
||||||
|
800 |
1750 |
7790 |
8260 |
8840 |
||||||
|
1000 |
2070 |
9220 |
9780 |
10400 |
||||||
|
1250 |
2380 |
10800 |
11500 |
12300 |
||||||
|
1600 |
2790 |
13000 |
13800 |
14800 |
||||||
|
2000 |
3240 |
15400 |
16300 |
17500 |
||||||
|
2500 |
18200 |
19300 |
20700 |
|||||||
|
2000 |
3240 |
16800 |
17800 |
19100 |
||||||
|
2500 |
3870 |
20000 |
21200 |
22700 |
||||||
Technical Parameter for35kV& 50kVA-2500kVA With Off CircuitDry Type Transformer
|
(KVA)Rated capacity |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
|
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
|
50 |
±2.5%±5%±5%±2×2.5% |
Dyn11Yyn0 |
450 |
1340 |
1420 |
1520 |
||||
|
100 |
630 |
1970 |
2090 |
2230 |
||||||
|
160 |
2650 |
2810 |
3000 |
|||||||
|
200 |
±2X2.5%±5% |
3130 |
3320 |
3550 |
||||||
|
250 |
3580 |
3800 |
4060 |
|||||||
|
315 |
1170 |
4250 |
4510 |
4820 |
||||||
|
400 |
1370 |
5100 |
5410 |
5790 |
||||||
|
500 |
1520 |
6270 |
6650 |
7110 |
||||||
|
630 |
1860 |
7250 |
7690 |
8230 |
||||||
|
800 |
2160 |
8600 |
9120 |
9760 |
||||||
|
1000 |
2430 |
9860 |
10400 |
11100 |
||||||
|
1250 |
2830 |
12000 |
12700 |
13600 |
||||||
|
1600 |
3240 |
14600 |
15400 |
16500 |
||||||
|
2000 |
3820 |
17200 |
18200 |
19500 |
||||||
|
2500 |
||||||||||
Technical Parameterfor SG(B)10 Series Non-encapsulated Class H Dry-type Transformer
|
Product Model No. |
Connection Group Symbol |
Loss W |
Impedance Voltage(%) |
No-load Current(%) |
Overall Dimension (without enclosure) mm |
Weight(Kg) |
|||||||
|
No-load Loss R |
145℃Load Loss R(W) |
L |
W |
H |
L1 |
L2 |
d |
f |
|||||
|
SG10-30/10 |
Y,yn0D,yn11 |
190 |
760 |
4 |
900 |
1180 |
880 |
265 |
220 |
550 |
550 |
420 |
|
|
SG10-50/10 |
270 |
1070 |
940 |
1180 |
985 |
295 |
220 |
550 |
550 |
450 |
|||
|
SG10-80/10 |
370 |
1480 |
985 |
1180 |
1055 |
295 |
226 |
550 |
660 |
740 |
|||
|
SG10-100/10 |
400 |
1690 |
1010 |
1180 |
1135 |
295 |
226 |
660 |
660 |
770 |
|||
|
SG10-125/10 |
470 |
1980 |
1060 |
1180 |
1175 |
306 |
228 |
660 |
820 |
1005 |
|||
|
SG10-160/10 |
540 |
2280 |
1120 |
1180 |
1230 |
312 |
228 |
660 |
820 |
1015 |
|||
|
SG10-200/10 |
620 |
2710 |
1180 |
1230 |
1275 |
312 |
238 |
660 |
820 |
1035 |
|||
|
SG10-250/10 |
720 |
2960 |
1290 |
1230 |
1330 |
315 |
238 |
660 |
820 |
1155 |
|||
|
SG10-315/10 |
880 |
3730 |
1320 |
1340 |
1355 |
315 |
240 |
820 |
1070 |
1365 |
|||
|
SGB10-400/10 |
980 |
4280 |
1350 |
1340 |
1435 |
315 |
240 |
820 |
1070 |
1585 |
|||
|
SGB10-500/10 |
1160 |
5230 |
1395 |
1340 |
1495 |
325 |
258 |
820 |
1070 |
1795 |
|||
|
SGB10-630/10 |
1345 |
6290 |
1450 |
1340 |
1550 |
325 |
268 |
820 |
1070 |
2265 |
|||
|
SGB10-630/10 |
1300 |
6400 |
1545 |
1340 |
1445 |
325 |
268 |
820 |
1070 |
1930 |
|||
|
SGB10-800/10 |
1520 |
7460 |
1590 |
1340 |
1490 |
330 |
273 |
820 |
1070 |
2450 |
|||
|
SGB10-1000/10 |
1770 |
8760 |
1680 |
1340 |
1555 |
330 |
276 |
820 |
1070 |
2640 |
|||
|
SGB10-1250/10 |
2090 |
10300 |
1710 |
1470 |
1635 |
335 |
286 |
820 |
1070 |
3170 |
|||
|
SGB10-1600/10 |
2450 |
12500 |
6 |
1800 |
1470 |
1770 |
350 |
330 |
1070 |
1070 |
3985 |
||
|
SGB10-2000/10 |
3050 |
15500 |
1850 |
1470 |
1890 |
350 |
346 |
1070 |
1070 |
4850 |
|||
|
SGB10-2500/10 |
3600 |
18400 |
1900 |
1470 |
2030 |
365 |
356 |
1070 |
1070 |
5620 |
|||
Notes:The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
在线联系供应商
Other supplier products
| Characteristics and properties of amorphous alloy transformer | Characteristics and properties of amorphous alloy transformer is a new type of energy saving transformer made of a new magnetic conducting material... | |
| step up dry transformer | step up dry transformer Dry Type Transformer Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, eas... | |
| Do You Know What Is The Short Circuit Impedance of The Transformer? | process of using, it is necessary to enhance the continuous improvement of the use and efficiency of the transformer such asDry Type Transformer.... | |
| Amorphous alloy power transformer China | is a new type of energy saving transformer made of a new magnetic conducting material (amorphous alloy). It is more than 70% lower than the no-loa... | |
| Working principle of transformer | Three phase transformer Manufacturershares that transformer is a kind of electric appliance that transfers electric energy or transmits signal fr... |
Same products
| China factory Transformer bushing BRDW-126/630-3 for power station | 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD | "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel... | |
| TOROIDAL TRANSFORMER | 卖方: Yu Yang Magnetic Co., LTD | Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >... | |
| ACREL AID150 ALARM AND DISPLAY DEVICE | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
| ACREL ANSVG STATIC VAR GENERATOR | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
| The Working Principle of Active Power Filter | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... |