SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection. It is the ideal product for distribution systems and widely used in the subway, shipbuilding, mining, chemical, power companies and personnel-intensive buildings as well as other special requirements of the occasion for safety.
Model and Meaning
SC(B)10 Series Resin-insulated Dry Type Transformer
SG (B) 10 series Non-encapsulated H-class Dry-type Power Transformers
Technical Parameter for6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer
Rated capacity(KVA) |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
30 |
±2X2.5%±5% |
Dyn11Yyn0 |
190 |
670 |
710 |
760 |
||||
50 |
270 |
940 |
1000 |
1070 |
||||||
80 |
370 |
1290 |
1380 |
1480 |
||||||
100 |
400 |
1480 |
1570 |
1690 |
||||||
125 |
470 |
1740 |
1850 |
1980 |
||||||
160 |
540 |
2000 |
2130 |
2280 |
||||||
200 |
±2X2.5%±5% |
620 |
2370 |
2530 |
2710 |
|||||
250 |
720 |
2590 |
2760 |
2960 |
||||||
315 |
880 |
3270 |
3470 |
3730 |
||||||
400 |
980 |
3750 |
3990 |
4280 |
||||||
500 |
1150 |
4590 |
4880 |
5230 |
||||||
630 |
1340 |
5530 |
5880 |
6290 |
||||||
630 |
1300 |
5610 |
5960 |
6400 |
||||||
800 |
1520 |
6550 |
6960 |
7460 |
||||||
1000 |
1770 |
7650 |
8130 |
8760 |
||||||
1250 |
2090 |
9100 |
9690 |
10300 |
||||||
1600 |
2450 |
11000 |
11700 |
12500 |
||||||
2000 |
3050 |
13600 |
14400 |
15500 |
||||||
2500 |
3600 |
16100 |
17100 |
18400 |
||||||
1600 |
2450 |
1220 |
12900 |
13900 |
||||||
2000 |
3050 |
15000 |
15900 |
17100 |
||||||
2500 |
3600 |
17700 |
18800 |
20200 |
Notes:The load losses listed in the table are the values of the reference temperature for different insulation systems inparentheses; The load losses under other insulation system temperatures that are not included in the table should be according to their respective reference temperatures, the corresponding calculation is based on the"- 155 ℃(F)" insulation system temperature data.
Notes:The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
Technical Parameter for20kV& 50kVA-2500kVA With Off CircuitDry Type Transformer
(KVA)Rated capacity |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
50 |
202224 |
±2.5%±5%±5%±2×2.5% |
Dyn11Yyn0 |
340 |
1160 |
1230 |
1310 |
|||
100 |
540 |
1870 |
1990 |
2130 |
||||||
160 |
2350 |
2470 |
3460 |
|||||||
200 |
±2X2.5%±5% |
730 |
2770 |
2940 |
3140 |
|||||
250 |
840 |
3220 |
3420 |
3660 |
||||||
315 |
970 |
3850 |
4080 |
4360 |
||||||
400 |
1150 |
4650 |
4840 |
5180 |
||||||
500 |
1350 |
5460 |
5790 |
6190 |
||||||
630 |
1530 |
6450 |
6840 |
7320 |
||||||
800 |
1750 |
7790 |
8260 |
8840 |
||||||
1000 |
2070 |
9220 |
9780 |
10400 |
||||||
1250 |
2380 |
10800 |
11500 |
12300 |
||||||
1600 |
2790 |
13000 |
13800 |
14800 |
||||||
2000 |
3240 |
15400 |
16300 |
17500 |
||||||
2500 |
18200 |
19300 |
20700 |
|||||||
2000 |
3240 |
16800 |
17800 |
19100 |
||||||
2500 |
3870 |
20000 |
21200 |
22700 |
Technical Parameter for35kV& 50kVA-2500kVA With Off CircuitDry Type Transformer
(KVA)Rated capacity |
Voltage Combination |
Connection Group Symbol |
No-load Loss(W) |
Load Loss (W) |
No-load Current (%) |
Short-circuit Impedance(%) |
||||
High Voltage (KV) |
Tapping rangesof High Voltage |
Low Voltage(KV) |
130℃(B)(100℃) |
155℃(F)(120℃) |
180℃(H)(145℃) |
|||||
50 |
±2.5%±5%±5%±2×2.5% |
Dyn11Yyn0 |
450 |
1340 |
1420 |
1520 |
||||
100 |
630 |
1970 |
2090 |
2230 |
||||||
160 |
2650 |
2810 |
3000 |
|||||||
200 |
±2X2.5%±5% |
3130 |
3320 |
3550 |
||||||
250 |
3580 |
3800 |
4060 |
|||||||
315 |
1170 |
4250 |
4510 |
4820 |
||||||
400 |
1370 |
5100 |
5410 |
5790 |
||||||
500 |
1520 |
6270 |
6650 |
7110 |
||||||
630 |
1860 |
7250 |
7690 |
8230 |
||||||
800 |
2160 |
8600 |
9120 |
9760 |
||||||
1000 |
2430 |
9860 |
10400 |
11100 |
||||||
1250 |
2830 |
12000 |
12700 |
13600 |
||||||
1600 |
3240 |
14600 |
15400 |
16500 |
||||||
2000 |
3820 |
17200 |
18200 |
19500 |
||||||
2500 |
Technical Parameterfor SG(B)10 Series Non-encapsulated Class H Dry-type Transformer
Product Model No. |
Connection Group Symbol |
Loss W |
Impedance Voltage(%) |
No-load Current(%) |
Overall Dimension (without enclosure) mm |
Weight(Kg) |
|||||||
No-load Loss R |
145℃Load Loss R(W) |
L |
W |
H |
L1 |
L2 |
d |
f |
|||||
SG10-30/10 |
Y,yn0D,yn11 |
190 |
760 |
4 |
900 |
1180 |
880 |
265 |
220 |
550 |
550 |
420 |
|
SG10-50/10 |
270 |
1070 |
940 |
1180 |
985 |
295 |
220 |
550 |
550 |
450 |
|||
SG10-80/10 |
370 |
1480 |
985 |
1180 |
1055 |
295 |
226 |
550 |
660 |
740 |
|||
SG10-100/10 |
400 |
1690 |
1010 |
1180 |
1135 |
295 |
226 |
660 |
660 |
770 |
|||
SG10-125/10 |
470 |
1980 |
1060 |
1180 |
1175 |
306 |
228 |
660 |
820 |
1005 |
|||
SG10-160/10 |
540 |
2280 |
1120 |
1180 |
1230 |
312 |
228 |
660 |
820 |
1015 |
|||
SG10-200/10 |
620 |
2710 |
1180 |
1230 |
1275 |
312 |
238 |
660 |
820 |
1035 |
|||
SG10-250/10 |
720 |
2960 |
1290 |
1230 |
1330 |
315 |
238 |
660 |
820 |
1155 |
|||
SG10-315/10 |
880 |
3730 |
1320 |
1340 |
1355 |
315 |
240 |
820 |
1070 |
1365 |
|||
SGB10-400/10 |
980 |
4280 |
1350 |
1340 |
1435 |
315 |
240 |
820 |
1070 |
1585 |
|||
SGB10-500/10 |
1160 |
5230 |
1395 |
1340 |
1495 |
325 |
258 |
820 |
1070 |
1795 |
|||
SGB10-630/10 |
1345 |
6290 |
1450 |
1340 |
1550 |
325 |
268 |
820 |
1070 |
2265 |
|||
SGB10-630/10 |
1300 |
6400 |
1545 |
1340 |
1445 |
325 |
268 |
820 |
1070 |
1930 |
|||
SGB10-800/10 |
1520 |
7460 |
1590 |
1340 |
1490 |
330 |
273 |
820 |
1070 |
2450 |
|||
SGB10-1000/10 |
1770 |
8760 |
1680 |
1340 |
1555 |
330 |
276 |
820 |
1070 |
2640 |
|||
SGB10-1250/10 |
2090 |
10300 |
1710 |
1470 |
1635 |
335 |
286 |
820 |
1070 |
3170 |
|||
SGB10-1600/10 |
2450 |
12500 |
6 |
1800 |
1470 |
1770 |
350 |
330 |
1070 |
1070 |
3985 |
||
SGB10-2000/10 |
3050 |
15500 |
1850 |
1470 |
1890 |
350 |
346 |
1070 |
1070 |
4850 |
|||
SGB10-2500/10 |
3600 |
18400 |
1900 |
1470 |
2030 |
365 |
356 |
1070 |
1070 |
5620 |
Notes:The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Send product request
Other supplier products
three phase variable transformer | 3 phase step down transformer Oil Immersed Transformer Model and Meaning Model No. Rated CapacityKVA Rated Voltage KV Connection Group Sy... | |
How to see the oil position of oil-immersed transformer? | oil-immersed transformeroil level gage to 30 °, + 20 ° and + 40 °, respectively is refers to the oil-immersed transformer at ambi... | |
Oil filled power transformer | Transformer is an important electrical equipment that must be used in our production and life. For transformer, it can control the voltage and cur... | |
How to calculate the calorific value of transformer | How to calculate the calorific value of transformer The calorific base of transformer = no load loss + load loss. No-load loss: when the transforme... | |
GCK Low-voltage Draw out Switchgear,Low Voltage Switchgear,Draw out Switchgear,Circuit Breaker Switchgear | GCK Low-voltage Draw out Switchgear,Low Voltage Switchgear,Draw out Switchgear,Circuit Breaker Switchgear High and Low Voltage Switchgears GCK se... |
Same products
S11-M Power Transformer | Seller: Bokong Electric Co., Ltd | S11-M Product Description S11-M a new generation of low noise and low loss transformer devel... | |
Compact Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | As a leading compact transformer substationmanufacturer and box type substation supplier, SEC com... | |
Combined Pad Mounted Substation | Seller: Shaanxi Hanzhong Transformer Co., ltd | Combined Pad Mounted Substation The ZBG series America Housing Type Transformer are researched a... | |
Amorphous Alloy Dry Type Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | SCBH15eres amorphous alloy dry type transformerpertorms well not only for its excellent propertie... | |
35KV Power Transformer | Seller: Shaanxi Hanzhong Transformer Co., ltd | This 35 KV transformerhas the characteristics of high efficiency and low loss, can save a lot of ... |