oil-immersed power transformers

The calorific base of transformer = no load loss + load loss.

No-load loss: when the transformer secondary winding is open and the primary winding applies the rated voltage of the rated frequency sinusoidal waveform, the active power consumed is called no-load loss.

Load loss: variable loss. It's proportional to the square of the current going through it. Load loss is the load loss at rated current and reference temperature. To expand, the so-called rated current refers to the primary side tapping position must be the main tapping, not the rated current of other tapping. For the reference temperature, it depends on the heat resistance grade of the insulation material of the transformer. For oil-immersed transformers, no matter they are self-cooled, air-cooled or strongly oil-cooled, they are all a-class insulation materials, and their reference temperature is specified according to the traditional concept, which is 75℃.

As atransformer manufacturer China ,ourcompany mainly produces:,, box-type substation, high and low voltage switchgear assembly and a variety of special-type transformers.


在线联系供应商

至: Baoding Zhongyi Electrical Material Manufacturing Co.,Ltd.
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

How to calculate the calorific value of transformer?
How to calculate the calorific value of transformer? How to calculate the calorific value of transformer? The calorific base of transformer = no load loss + load loss. No-load loss: when the transfo...
How to Dry the Transformer?
How to Dry the Transformer? Transformers such asOil Immersed Transformerare sometimes wet, especially in the summer when the transformer is relatively powerful, and the power...
ZBW Type Prefabricated Substation,mobile transformer substation,distribution transformer substation,power substation transformer
ZBW Type Prefabricated Substation,mobile transformer substation,distribution transformer substation,power substation transformer ZBW Type Prefabricated Substation,mobile transformer substation,distribution transformer substation,power substation transformer ZBW Type Prefabric...
What Are the Common Drying Methods for Transformers?
What Are the Common Drying Methods for Transformers? The following are common drying methods for transformers such asH Class Dry Type Transformerfor your reference: (1) If the transformer drying ch...
oil-immersed power transformers
oil-immersed power transformers The calorific base of transformer = no load loss + load loss. No-load loss: when the transformer secondary winding is open and the primary winding...
供应产品

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER 卖方: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...