[FA-] MPY, MPYC, MPYCY

Standards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed stranded copper,Website:, class 2 according to IEC 60228InsulationP85°C EPR as per JIS C 3401CablingInsulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be usedBeddingYPVC as per JIS C 3401ArmorCGalvanized steel wire braidSheathYPVC as per JIS C 3401Core identificationBlack No. on white insulation /Black No. on white insulation, G/YOuter sheath colorBlackCable Parameter250V (FA-) MPYNo. of coresConductorThick. of insulationThick. of bedding(FA-) MPYSizeConstructionO.DNom. overall diaToleranceCable Weightmm2No./mmmmmmmmmmmmkg/km217/0.431.290.71.18.70.485417/0.431.290.71.19.90.4125717/0.431.290.71.211.90.51901217/0.431.290.71.315.50.73151917/0.431.290.71.418.30.84652717/0.431.290.71.622.10.96653717/0.431.290.71.724.818704417/0.431.290.71.8281.211607717/0.431.290.72.135.91.51790250V (FA-) MPYCNo. of coresConductorThick. of insulationThick. of beddingDia. of steel wire(FA-) MPYCSizeConstructionO.DNom. overall diaToleranceCable Weightmm2No./mmmmmmmmmmmmmmkg/km217/0.431.290.71.10.3100.4155417/0.431.290.71.10.311.20.4205717/0.431.290.71.20.313.20.52901217/0.431.290.71.30.316.80.74451917/0.431.290.71.40.319.60.86152717/0.431.290.71.60.323.40.98403717/0.431.290.71.70.326.1110704417/0.431.290.71.80.329.31.212907717/0.431.290.72.10.437.71.52180250V (FA-) MPYCYNo. of coresConductorThick. of insulationThick. of beddingDia. of steel wireThick. of covering(FA-) MPYCYSizeConstructionO.DNom. overall diaToleranceCable Weightmm2No./mmmmmmmmmmmmmmmmkg/km217/0.431.290.71.10.30.9120.5205417/0.431.290.71.10.30.913.20.5260717/0.431.290.71.20.30.915.20.63501217/0.431.290.71.30.31190.85301917/0.431.290.71.40.31.1220.97202717/0.431.290.71.60.31./0.431.290.71.70.31.328.91.212404417/0.431.290.71.80.31.332.11.314707717/0.431.290.72.10.41.541.11.62470
Other supplier products
|
|
|
German Standard Industrial Cables LiY / LiYv / LiYv-tApplication and DescriptionThese PVC insulated stranded hook-up wires are employed in telecomm... |
|
|
|
600/1000V Mica+XLPE Insulated,Website:, LSZH Sheathed fire resistant Power Cables (Single-Core)Unarmoured Single core (CU/MGT+XLPE/LSZH 600/1000V C... |
|
|
|
P1 or P1/P8 RFOU/TFOU 0.6/1KV NEK606 Power cableApplications :Marine cables are flame retardant,Website:, low smoke, halogen free and mud resistant... |
|
|
|
P2 or P2/P9 RFOU/TFOU 3.6/6KV NEK606 MV cableApplications :These cables are flame retardant,Website:, low smoke, halogen free and mud resistant, us... |
|
|
|
Standards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed stranded copper,Website:, class 2 acco... |
供应产品
Same products