150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Fire Resistant Instrumentation Control Cables

Fire Resistant 150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Armoured Instrumentation & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Lay-up: Pairs, triples.Collective Screen: Aluminium/polyester tape + drain wire tinned copper.Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 8×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightConstruction
No. of cores×Cross section(mm²)Nominal Insulation Thickness
mmNominal Sheath Thickness
mmMinimum Overall Diameter
mmMaximum Overall Diameter
mmApprox. Weight
kg/kmMultipair3×2×0.750.81.214.016.02027×2×0.750.81.418.620.738312×2×0.750.81.624.427.061520×2×0.750.81.830.834.084127×2×0.750.81.935.038.4126537×2×0.750.82.138.842.617073×2×10.81.214.816.82087×2×10.81.419.622.041312×2×10.81.625.828.568320×2×10.81.832.635.8107027×2×10.82.037.340.8142137×2×10.82.241.345.21912Multitriple3×3×0.750.81.315.017.02447×3×0.750.81.420.523.045712×3×0.750.81.725.628.37583×3×10.81.315.817.82707×3×10.81.521.924.452112×3×10.81.727.129.8857
Other supplier products
|
|
|
UL Industrial Cables HMWPE Catdodic Protection Power CableApplicationTheses cables are designed for use witd cathodic systems protecting against ga... |
|
|
|
P15 UX 0.6/1kV NEK606 Earthing cableApplications :These cables are flame retardant,Website:, low smoke and halogen free, used for earthing and bond... |
|
|
|
N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre OpticsApplicationsThese cables are used for laying alongside the conveyor belts (... |
|
|
|
300/500V Mica+XLPE Insulated,Website:, LSZH Sheathed fire resistant Power Cables (Single Core)(CU/MGT+XLPE/LSZH 300/500V Class 2)Application:These ... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9838ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |