150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Fire Resistant Instrumentation Control Cables

Fire Resistant 150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Armoured Instrumentation & Control CablesApplication:These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.Standards:BS 7917IEC 60331-31 Fire resistantIEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.Lay-up: Pairs, triples.Collective Screen: Aluminium/polyester tape + drain wire tinned copper.Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 8×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightConstruction
No. of cores×Cross section(mm²)Nominal Insulation Thickness
mmNominal Sheath Thickness
mmMinimum Overall Diameter
mmMaximum Overall Diameter
mmApprox. Weight
kg/kmMultipair3×2×0.750.81.214.016.02027×2×0.750.81.418.620.738312×2×0.750.81.624.427.061520×2×0.750.81.830.834.084127×2×0.750.81.935.038.4126537×2×0.750.82.138.842.617073×2×10.81.214.816.82087×2×10.81.419.622.041312×2×10.81.625.828.568320×2×10.81.832.635.8107027×2×10.82.037.340.8142137×2×10.82.241.345.21912Multitriple3×3×0.750.81.315.017.02447×3×0.750.81.420.523.045712×3×0.750.81.725.628.37583×3×10.81.315.817.82707×3×10.81.521.924.452112×3×10.81.727.129.8857
Other supplier products
|
|
|
S15 BFOU-HCF(i) 250 V Fire Resistant Instrument cable NEK 606Applications :These cables are fire resistant,Website:, flame retardant, low smoke and... |
|
|
|
Standards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed stranded copper,Website:, class 2 acco... |
|
|
|
P18 RU 0.6/1kV NEK606 CableApplications :These cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used for control, po... |
|
|
|
UL Industrial Cables RHH RHW-LS USE,Website:, XLPO, LSOH CSA AWM I A B, ClassApplication and DescriptionRHH/RHW-2/USE-2, XLPO type is for use in co... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8340ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
供应产品
Same products