150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation Control Cables

150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control CablesApplication:These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.Standards:BS 6883IEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: HF-EPR GP4 according to BS 7655 1.2.Lay-up: Pairs, triples, quads.Individual Screen: Aluminium/polyester tape + drain wire tinned copper.Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 8×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightConstruction
No. of cores×Cross section(mm²)Nominal Insulation Thickness
mmNominal Inner Sheath Thickness
mmMinimum Diameter Over Inner Sheath
mmMaximum Diameter Over Inner Sheath
mmNominal Armour Wire Diameter
mmNominal Outer Sheath Thickness
mmMinimum Overall Diameter
mmMaximum Overall Diameter
mmApprox. Weight
kg/kmMultipair1×2×0.750.81.07.39.00.31.211.112.92503×2×0.750.81.212.614.50.31.416.719.04407×2×0.750.81.416.919.00.31.621.424.373012×2×0.750.81.621.323.70.31.826.129.2109020×2×0.750.81.927.029.80.452.133.237.0175027×2×0.750.82.030.833.90.452.337.341.3219037×2×0.750.82.235.939.30.452.542.947.527801×2×10.81.07.79.50.31.211.513.42603×2×10.81.313.515.50.31.417.620.04907×2×10.81.418.020.10.31.622.525.481012×2×10.81.722.825.40.451.928.631.8137020×2×10.81.928.831.60.452.235.239.0201027×2×10.82.132.836.00.452.439.544.0257037×2×10.82.338.542.30.452.645.750.43290Multitriple1×3×0.750.81.07.79.40.31.211.513.32703×3×0.750.81.314.216.20.31.518.620.95407×3×0.750.81.519.722.10.31.724.427.491012×3×0.750.81.724.427.10.452.030.434.115001×3×10.81.18.410.10.31.212.114.02903×3×10.81.315.017.20.31.519.422.36007×3×10.81.521.023.50.31.725.728.8103012×3×10.81.826.228.90.452.032.236.01740Multiquad1×4×0.750.81.18.610.40.31.212.414.32903×4×0.750.81.416.418.50.31.520.923.86107×4×0.750.81.622.124.70.31.727.030.210601×4×10.81.19.110.90.31.212.914.83303×4×10.81.417.519.60.31.622.024.96807×4×10.81.623.626.20.451.829.432.01290
Other supplier products
|
|
|
German Standard Industrial Cables H05G-U/H07G-U/RApplication and DescriptionThese cables are recommended for the internal wiring of switchboards an... |
|
|
|
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These elastomeric insulated cables... |
|
|
|
German Standard Industrial Cables LiHCH TPApplication and DescriptionLiHCH TP is for use in flexible or stationary applications under low mechanica... |
|
|
|
XLPE Insulated,Website:, LSZH sheathed, CWB screened Instrumentation cables (Multipair)RE-2X(c)H 90°c / 300VSTANDARDSBasic design to EN 50288-7APPL... |
|
|
|
NF M 87-202 EGSFAPPLICATIONThese NF M 87-202 EGSF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units par... |