.

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation Control Cables

150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control CablesApplication:These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.Standards:BS 6883IEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: HF-EPR GP4 according to BS 7655 1.2.Lay-up: Pairs, triples, quads.Individual Screen: Aluminium/polyester tape + drain wire tinned copper.Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 8×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightConstruction      No. of cores×Cross section(mm²)Nominal Insulation Thickness      mmNominal Inner Sheath Thickness      mmMinimum Diameter Over Inner Sheath      mmMaximum Diameter Over Inner Sheath      mmNominal Armour Wire Diameter      mmNominal Outer Sheath Thickness      mmMinimum Overall Diameter      mmMaximum Overall Diameter      mmApprox. Weight      kg/kmMultipair1×2×0.750.81.07.39.00.31.211.112.92503×2×0.750.81.212.614.50.31.416.719.04407×2×0.750.81.416.919.00.31.621.424.373012×2×0.750.81.621.323.70.31.826.129.2109020×2×0.750.81.927.029.80.452.133.237.0175027×2×0.750.82.030.833.90.452.337.341.3219037×2×0.750.82.235.939.30.452.542.947.527801×2×10.81.07.79.50.31.211.513.42603×2×10.81.313.515.50.31.417.620.04907×2×10.81.418.020.10.31.622.525.481012×2×10.81.722.825.40.451.928.631.8137020×2×10.81.928.831.60.452.235.239.0201027×2×10.82.132.836.00.452.439.544.0257037×2×10.82.338.542.30.452.645.750.43290Multitriple1×3×0.750.81.07.79.40.31.211.513.32703×3×0.750.81.314.216.20.31.518.620.95407×3×0.750.81.519.722.10.31.724.427.491012×3×0.750.81.724.427.10.452.030.434.115001×3×10.81.18.410.10.31.212.114.02903×3×10.81.315.017.20.31.519.422.36007×3×10.81.521.023.50.31.725.728.8103012×3×10.81.826.228.90.452.032.236.01740Multiquad1×4×0.750.81.18.610.40.31.212.414.32903×4×0.750.81.416.418.50.31.520.923.86107×4×0.750.81.622.124.70.31.727.030.210601×4×10.81.19.110.90.31.212.914.83303×4×10.81.417.519.60.31.622.024.96807×4×10.81.623.626.20.451.829.432.01290

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation Control Cables (Multipair)
150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation Control Cables (Multipair) 150/250V Mica Tape + HEPR Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair)Application...
PE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Single Pair)
PE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Single Pair) PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Pair)RE-2Y(St)H 90°C / 300VSTANDARDSBasic design to EN 50288...
300/500V XLPE Insulated LSZH Sheathed Flame Retardant Power Cables (single Core)
300/500V XLPE Insulated LSZH Sheathed Flame Retardant Power Cables (single Core) 300/500V XLPE Insulated LSZH sheathed Flame retardant Power Cables (single core) Application:The cables are mainly used in power stations,Website:,...
Cat 5e F/UTP 24AWG
Cat 5e F/UTP 24AWG Cat 5e F/UTP 24AWG IEC60092ApplicationThese Cat5e F/UTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can support ...
H05VVD3H6-F
H05VVD3H6-F German Standard Industrial Cables H05VVD3H6-FApplication and DescriptionThese cables are generally used in crews of,Website:, elevators for people ...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes