H05Z-K/H07Z-K

VDE Standard Industrial Cables H05Z-K/H07Z-KApplication and DescriptionThese cables are designed for tde internal wiring of switchboards and distributor boards witd an alternating nominal voltage up to 1000 Volts or a direct voltage up to 750 volts. Generally install in pipes or ducts and internal wiring of appliances witd maximum operating temperature of 90º C,Website:, and generally in areas (such as public and government buildings) where smoke and toxic fumes may cause a tdreat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.Standard and ApprovalHD 22.9 S2, VDE-0282 Part-9, BS 7211, IEC 60754-2, EN 50267, VDE 0482-267, CE Low Voltage Directive 73/23/EEC and 93/68/EEC, ROHS compliantCable Construction- Fine bare copper strands- Strands to VDE-0295 Class-5, IEC 60228 Class-5 BS 6360 cl. 5, HD 383- Cross-link polyolefin EI5 core insulation- LSOH - low smoke, zero halogenTechnical Characteristics- Working voltage: 300/500v (H05Z-K), 450/750v (H07Z-K)- Test voltage: 2500 volts- Flexing bending radius: 8 x Ø- Static bending radius: 8 x Ø- Flexing temperature: -15º C to +90º C- Static temperature: -40º C to +90º C- Flame retardant: IEC 60332.1- Insulation resistance: 10 MΩ x km- Smoke density acc. to EN 50268 / IEC 61034- Corrosiveness of combustion gases acc. to EN 50267-2-2, IEC 60754-2- Flame test: flame-retardant acc. to EN 50265-2-1, IEC 60332.1Cable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # XMM²NOMINAL THICKNESS OF INSULATIONMMNOMINAL OVERALL DIAMETERMMNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KMH05Z-K20(16/32)1 x 0.50.62.34.8918(24/32)1 x 0.750.62.57.212.417(32/32)1 x 10.62.69.615H07Z-K16(30/30)1 x 1.50.73.514.42414(50/30)1 x 2.50./28)1 x 40.84.8385110(84/28)1 x 60.8658718(80/26)1 x 101.06./26)1 x 161.08./26)1 x 251.210./26)1 x 351.211./26)1 x 501.413.64805602/0(356/24)1 x 701.4166727803/0(485/24)1 x 951.618.49129524/0(614/24)1 x 1201.620. MCM (765/24)1 x 1501.822. MCM (944/24)1 x 1852.025.MCM(1225/24)1 x 2402.228.323042400
Other supplier products
|
|
|
S13 BU(i) 250 V Individual Shielding fire resistant NEK606 Instrument cableApplications :These cables are fire resistant,Website:, flame retardant,... |
|
|
|
0.6/1kV HF-EPR Insulated,Website:, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These elastomeric insulated cables... |
|
|
|
Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables CAT6 U/UTP4P23CAT6 F/UTP4P23CAT6 SF/FTP4P23Application:Cat6 Cable is a cable standard for Gig... |
|
|
|
UL Industrial Cables XHHW/PVC,Website: TC Power CableApplication and DescriptionXHHW/PVC, type TC Power Cable is used to supply power to motors, or... |
|
|
|
NSHTOEU 0.6/1kV LHD Cables VDE 0250 Part 814ApplicationsThese cables are used for frequently changing dynamic loads,Website:, such as reeling cable... |