NAYY-J/NAYY-O

German Standard Industrial Cables NAYY-J/NAYY-OApplication and DescriptionNAYY is used in power plants industrial and switching installations,Website:, in secondary distribution networks and otder. These cables are preferentially used in outdoor applications, for indoor installations, in tde open air, underground and in water where mechanical damage is not anticipated.Standard and ApprovalVDE 0276 part 603, IEC 60502Cable Construction- Aluminium Conductor- VDE 0295 cl. 1 or cl. 2 (round and sector shaped), BS 6360/IEC 60228 cl. 1 or cl. 2- PVC insulation type DIV4 acc. VDE0207- Color coded to DIN VDE 0293- PVC compound inner sheatd- PVC outer sheatd type DMV5 acc. VDE 0207Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 4000 volts- Minimum bending radius: 12 x Ø- Flexing temperature: -5º C to +50º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +160º C- Flame-retardant to DIN VDE 0472 part 804 class B/IEC 60332-1Cable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²STRANDED CONDUCTOR TYPENOMINALOVERALL DIAMETER MMALUMINIUMWEIGHTKG/KMNOMINAL CABLEWEIGHTKG/KMNAYY-O41 x 25.0re12.27019021 x 35.0re13.19722911 x 50.0re14.513128811 x 50.0rm15.41353032/01 x 70.0rm17.11953853/01 x 95.0rm19.32704994/01 x 120.0rm20.8341589300mcm1 x 150.0rm22.6419705350mcm1 x 185.0rm24.9526862500mcm1 x 240.0rm27.mcm1 x 300.0rm30.68631325-1 x 400.0rm34. x 500.0rm38. x 25.0re22.414068522x 35.0re24.319482622 x 35.0rm25.419988012 x 50.0re27.3261104912 x 50.0rm29.126911552/02 x 70.0rm33.139014473/02 x 95.0rm37.95391905NAYY-J43 x 25.0re23.721076823 x 35.0re25.829193213 x 50.0sm30.9404129413 x 50.0sm27.84049942/03 x 70.0sm31.258412503/03 x 95.0sm35.880916754/03 x 120.0sm38.mcm3 x 150.0sm41.mcm3 x 185.0sm45.mcm3 x 240.0sm51. x 50.0+25re+re30.5462131013 x 50.0+25sm+rm31.247411582/03 x 70.0+35sm+rm36.068415373/03 x 95.0+50sm+rm40.294419714/03x120.0+70sm+rm43.mcm3 x 150.0+70sm+rm48.mcm3 x 185.0+95sm+rm52.mcm3x240.0+120sm+rm58.mcm3x300.0+150sm+rm64. x 25.0re25.828191224 x 35.0re28.2388111114 x 50.0se31.253912652/04 x 70.0se36.077916583/04 x 95.0se40.2107921394/04 x120.0se43.mcm4 x 150.0se48.mcm4 x 185.0se53.mcm4 x 240.0se58.mcm4 x 300.0se64. x 25.0re28.1351107225 x 35.0re30.9485132615 x 50.0re35.7653177145 x 25.0rm30.4360118325 x 35.0rm33.0497145615 x 50.0rm38.167319192/05 x 70.0rm43.397424523/05 x 95.0rm49.813493257
Other supplier products
|
|
|
XLPE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multitriple)RE-2X(St)H 90°C / 300 VSTANDARDSBasic design to EN 50... |
|
|
|
Three Core Medium Power Cable to BS 6622
Application:
... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Individual and Overall Screened Instrumentation Cables (Multipair)RE-2Y(St)H Pimf 90°C / 300VSTANDARDSBasic d... |
|
|
|
Type 409 1.1 to 22KV to AS/NZS 2802ApplicationsType 409 series cable is mainly used as a flexible feeder to machinery,Website:, more suitable as a ... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Double steel tape armoured Power Cables (2 Cores)CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2Application... |
供应产品
Same products