NAYY-J/NAYY-O

German Standard Industrial Cables NAYY-J/NAYY-OApplication and DescriptionNAYY is used in power plants industrial and switching installations,Website:, in secondary distribution networks and otder. These cables are preferentially used in outdoor applications, for indoor installations, in tde open air, underground and in water where mechanical damage is not anticipated.Standard and ApprovalVDE 0276 part 603, IEC 60502Cable Construction- Aluminium Conductor- VDE 0295 cl. 1 or cl. 2 (round and sector shaped), BS 6360/IEC 60228 cl. 1 or cl. 2- PVC insulation type DIV4 acc. VDE0207- Color coded to DIN VDE 0293- PVC compound inner sheatd- PVC outer sheatd type DMV5 acc. VDE 0207Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 4000 volts- Minimum bending radius: 12 x Ø- Flexing temperature: -5º C to +50º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +160º C- Flame-retardant to DIN VDE 0472 part 804 class B/IEC 60332-1Cable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²STRANDED CONDUCTOR TYPENOMINALOVERALL DIAMETER MMALUMINIUMWEIGHTKG/KMNOMINAL CABLEWEIGHTKG/KMNAYY-O41 x 25.0re12.27019021 x 35.0re13.19722911 x 50.0re14.513128811 x 50.0rm15.41353032/01 x 70.0rm17.11953853/01 x 95.0rm19.32704994/01 x 120.0rm20.8341589300mcm1 x 150.0rm22.6419705350mcm1 x 185.0rm24.9526862500mcm1 x 240.0rm27.mcm1 x 300.0rm30.68631325-1 x 400.0rm34. x 500.0rm38. x 25.0re22.414068522x 35.0re24.319482622 x 35.0rm25.419988012 x 50.0re27.3261104912 x 50.0rm29.126911552/02 x 70.0rm33.139014473/02 x 95.0rm37.95391905NAYY-J43 x 25.0re23.721076823 x 35.0re25.829193213 x 50.0sm30.9404129413 x 50.0sm27.84049942/03 x 70.0sm31.258412503/03 x 95.0sm35.880916754/03 x 120.0sm38.mcm3 x 150.0sm41.mcm3 x 185.0sm45.mcm3 x 240.0sm51. x 50.0+25re+re30.5462131013 x 50.0+25sm+rm31.247411582/03 x 70.0+35sm+rm36.068415373/03 x 95.0+50sm+rm40.294419714/03x120.0+70sm+rm43.mcm3 x 150.0+70sm+rm48.mcm3 x 185.0+95sm+rm52.mcm3x240.0+120sm+rm58.mcm3x300.0+150sm+rm64. x 25.0re25.828191224 x 35.0re28.2388111114 x 50.0se31.253912652/04 x 70.0se36.077916583/04 x 95.0se40.2107921394/04 x120.0se43.mcm4 x 150.0se48.mcm4 x 185.0se53.mcm4 x 240.0se58.mcm4 x 300.0se64. x 25.0re28.1351107225 x 35.0re30.9485132615 x 50.0re35.7653177145 x 25.0rm30.4360118325 x 35.0rm33.0497145615 x 50.0rm38.167319192/05 x 70.0rm43.397424523/05 x 95.0rm49.813493257
Other supplier products
|
|
|
S10 IYOI(c) 60 V NEK606 Armoured Tele cableApplications :These cables are flame retardant,Website:, low smoke and halogen free, used for indoor tel... |
|
|
|
Flame Retardant CAT5e Data Cables Application:Cat5E is a cable standard for Gigabit Ethernet and other network protocol,Website:, suitable for basi... |
|
|
|
Type 1 1.1/1.1KV Individually Screened to AS/NZS 1972/1125/3808ApplicationsThese individually copper screened cables are used for wiring of machine... |
|
|
|
PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multicore)RE-2Y(St)H 90°C / 500VSTANDARDSBasic design to EN 50288-7... |
|
|
|
225V SR Insulated & LSZH Sheathed Fire Alarm CablesJE-H(St)H…Bd FE180 E30 (CU/SR/OS/LSZH 225V Class 1)JE-H(St)HSWAH…Bd FE180 E30 (CU/SR/OS/LSZH/SWA... |