.

PE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Multicore)

PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multicore)RE-2Y(St)H 90°C / 500VSTANDARDSBasic design to EN 50288-7APPLICATIONThe LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas. Generally, the cables are used within industrial process manufacturing plants for communication, data and voice transmission signals and services. Also used for the interconnection of electrical equipment and instruments, the LSZH sheath can reduce toxic smoke and fume emission.FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ;CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ;CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil ResistanceICEA S-73-532**Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.VOLTAGE RATING500VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:PE compound, EN 50290. 2-23.Overall Screen:Aluminium/polyester tape with 0.5mm2 screen (7/0.3mm) tinned copper drain wire.Inner Sheath(optional):LSZH compoundArmouring(optional):Galvanised steel wireOuter Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / Blue, continuously numbered on blue core(1, 2..) for wrapped conductorOuter Sheath:Black or blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30°C – +90°CTemperature Range During Installation (Mobile State):-5°C – +50°CMinimum Bending Radius:7.5 X Overall DiameterCONSTRUCTION PARAMETERSCable CodeRE-2Y(St)HNo. of Coresx1xCross SectionNominalInsulationThicknessNominalOuter SheathThicknessNominalOverallDiameterApprox.WeightNo.x1xmm²mmmmmmkg/km0.5mm², MulticoreRE-2Y(St)H 2C0.52x1x0.50.550.96.245RE-2Y(St)H 3C0.53x1x0.50.550.96.553RE-2Y(St)H 4C0.54x1x0.50.550.97.060RE-2Y(St)H 5C0.55x1x0.50.550.97.671RE-2Y(St)H 8C0.58x1x0.50.551.09.195RE-2Y(St)H 10C0.510x1x0.50.551.010.4122RE-2Y(St)H 12C0.512x1x0.50.551.010.7145RE-2Y(St)H 14C0.514x1x0.50.551.011.3162RE-2Y(St)H 16C0.516x1x0.50.551.111.8180RE-2Y(St)H 20C0.520x1x0.50.551.113.3214RE-2Y(St)H 24C0.524x1x0.50.551.114.7258RE-2Y(St)H 27C0.527x1x0.50.551.215.0282RE-2Y(St)H 30C0.530x1x0.50.551.215.7308RE-2Y(St)H 37C0.537x1x0.50.551.216.9372RE-2Y(St)H 40C0.540x1x0.50.551.217.63980.75mm², MulticoreRE-2Y(St)H 2C0.752x1x0.750.550.96.5RE-2Y(St)H 3C0.753x1x0.750.550.96.9RE-2Y(St)H 4C0.754x1x0.750.550.97.4RE-2Y(St)H 5C0.755x1x0.750.550.98.1RE-2Y(St)H 8C0.758x1x0.750.551.09.7RE-2Y(St)H 10C0.7510x1x0.750.551.011.1RE-2Y(St)H 12C0.7512x1x0.750.551.011.5RE-2Y(St)H 14C0.7514x1x0.750.551.112.2RE-2Y(St)H 16C0.7516x1x0.750.551.112.9RE-2Y(St)H 20C0.7520x1x0.750.551.114.3RE-2Y(St)H 24C0.7524x1x0.750.551.216.0RE-2Y(St)H 27C0.7527x1x0.750.551.216.3RE-2Y(St)H 30C0.7530x1x0.750.551.216.9RE-2Y(St)H 37C0.7537x1x0.750.551.218.2RE-2Y(St)H 40C0.7540x1x0.750.551.319.11.0mm², MulticoreRE-2Y(St)H 2C1.02x1x1.00.550.96.958RE-2Y(St)H 3C1.03x1x1.00.550.97.370RE-2Y(St)H 4C1.04x1x1.00.550.97.985RE-2Y(St)H 5C1.05x1x1.00.550.98.698RE-2Y(St)H 8C1.08x1x1.00.551.010.3136RE-2Y(St)H 10C1.010x1x1.00.551.011.9194RE-2Y(St)H 12C1.012x1x1.00.551.012.2214RE-2Y(St)H 14C1.014x1x1.00.551.113.0243RE-2Y(St)H 16C1.016x1x1.00.551.113.7280RE-2Y(St)H 20C1.020x1x1.00.551.115.2336RE-2Y(St)H 24C1.024x1x1.00.551.217.0404RE-2Y(St)H 27C1.027x1x1.00.551.217.4443RE-2Y(St)H 30C1.030x1x1.00.551.218.0484RE-2Y(St)H 37C1.037x1x1.00.551.219.6590RE-2Y(St)H 40C1.040x1x1.00.551.320.46321.3mm², MulticoreRE-2Y(St)H 2C1.32x1x1.30.60.97.472RE-2Y(St)H 3C1.33x1x1.30.60.97.986RE-2Y(St)H 4C1.34x1x1.30.60.98.5105RE-2Y(St)H 5C1.35x1x1.30.61.09.5135RE-2Y(St)H 8C1.38x1x1.30.61.011.2176RE-2Y(St)H 10C1.310x1x1.30.61.113.2228RE-2Y(St)H 12C1.312x1x1.30.61.113.6269RE-2Y(St)H 14C1.314x1x1.30.61.114.3305RE-2Y(St)H 16C1.316x1x1.30.61.115.0351RE-2Y(St)H 20C1.320x1x1.30.61.216.9423RE-2Y(St)H 24C1.324x1x1.30.61.218.7507RE-2Y(St)H 27C1.327x1x1.30.61.319.3558RE-2Y(St)H 30C1.330x1x1.30.61.320.0611RE-2Y(St)H 37C1.337x1x1.30.61.321.6743RE-2Y(St)H 40C1.340x1x1.30.61.422.77961.5mm², MulticoreRE-2Y(St)H 2C1.52x1x1.50.60.97.778RE-2Y(St)H 3C1.53x1x1.50.60.98.194RE-2Y(St)H 4C1.54x1x1.50.60.98.8116RE-2Y(St)H 5C1.55x1x1.50.61.09.8149RE-2Y(St)H 8C1.58x1x1.50.61.011.6196RE-2Y(St)H 10C1.510x1x1.50.61.113.7261RE-2Y(St)H 12C1.512x1x1.50.61.114.1300RE-2Y(St)H 14C1.514x1x1.50.61.114.8340RE-2Y(St)H 16C1.516x1x1.50.61.115.6392RE-2Y(St)H 20C1.520x1x1.50.61.217.6474RE-2Y(St)H 24C1.524x1x1.50.61.319.6567RE-2Y(St)H 27C1.527x1x1.50.61.320.1625RE-2Y(St)H 30C1.530x1x1.50.61.320.8685RE-2Y(St)H 37C1.537x1x1.50.61.422.6834RE-2Y(St)H 40C1.540x1x1.50.61.423.68982.5mm², MulticoreRE-2Y(St)H 2C2.52x1x2.50.70.98.9113RE-2Y(St)H 3C2.53x1x2.50.71.09.7145RE-2Y(St)H 4C2.54x1x2.50.71.010.5178RE-2Y(St)H 5C2.55x1x2.50.71.011.9285RE-2Y(St)H 8C2.58x1x2.50.71.113.9376RE-2Y(St)H 10C2.510x1x2.50.71.216.3426RE-2Y(St)H 12C2.512x1x2.50.71.216.9537RE-2Y(St)H 14C2.514x1x2.50.71.217.7609RE-2Y(St)H 16C2.516x1x2.50.71.318.9711RE-2Y(St)H 20C2.520x1x2.50.71.321.1826RE-2Y(St)H 24C2.524x1x2.50.71.423.6930RE-2Y(St)H 27C2.527x1x2.50.71.424.11040RE-2Y(St)H 30C2.530x1x2.50.71.525.21142RE-2Y(St)H 37C2.537x1x2.50.71.527.21392RE-2Y(St)H 40C2.540x1x2.50.71.628.51494Note : Other conductor sizes & core configurations are available upon requestElectrical PROPERTIESConductor Area Sizemm²0.50.751.01.31.52.5Insulation thickness (nominal)mm0.550.550.550.60.60.7Conductor resistance (20°C)Ω/km36.024.518.113.912.17.4Insulation resistance (20°C)MΩ.km(Min.)5000Mutual Capacitance (1 kHz)pF/m(Max.)115Capacitance unbalance(1 kHz)pF/500 m (Max.)500L / R (ratio) (max.)μH/ΩOperating voltageV500Test Voltage UrmsCore to CoreV2000Core to ScreenV2000


在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used as power supply or connection cables for large...
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9843ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s...
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multicore)RE-2Y(St)HSWAH 90°C / 500VSTANDARDSBasic design...
VDE Standard Industrial Cables H05VV-F/H05VVH2-F Application and DescriptionThese cables are suited for medium mechanical stress in damp and wet en...
UL Industrial Cables XHH / XHHW-2Application and DescriptionThe XHH conductor is suitable for most current wiring solutions for residential,Website...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes