600 1000V XLPE Insulated, PVC Sheathed, Double Steel Tape Armoured Power Cables (2 Cores)

600/1000V XLPE Insulated,Website:, PVC Sheathed, Double steel tape armoured Power Cables (2 Cores)CU/XLPE/PVC/DSTA/PVC 600/1000V Class 2Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design adapted to IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING600/1000VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, normal stranded or compact stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Filler, binder and inner covering: PP, PET, PVCArmouring: Double steel tapeOuter Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C for XLPE250°C in short-circuit for 5secs max.Minimum bending radius: 10x Overall DiameterCONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter of StrandsDiameter Overall ConducrtorNominal Insulation ThicknessSteel Tape ThicknessNominal Sheath ThicknessNominal Overall DiameterMax.DC resistance of conductor Weightmm2No/mmmmmmmmmmmmΩ/kmKg/km2x67/1.042.900.70.21.816.83.084172x107/1.353.750.70.21.818.51.835392x167/1.704.750.70.21.820.51.157042x257/2.145.850.90.21.823.50.7279712x357/2.526.900.90.21.825.60.5241,2162x5O19/1.788.151.00.21.828.50.3871,5822x7019/2.149.751.10.21.932.30.26820812x9519/2.5211.451.10.22.036.40.19327492x12037/2.0312.851.20.52.241.10.1533,7272x15037/2.2514.301.40.52.345.10.1244,5092x18537/2.5215.951.60.52.549.90.09915,5232x24061/2.2518.251.70.52.655.30.075469812x30061/2.5220.401.80.52.860.70.06018,3832x40061/2.8523.352.00.53.067.90.047010,897Electrical PropertiesConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm2AAAAAAAAVoltage Drop (Per Amp Per Meter)Conductor cross-sectional area2-core cable d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c.3 or 4 cables, 3-phase a.c.In ducts or in groundIn ducts or in ground123456mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m67.97.96.87.96.5104.74.74.04.73.9162.92.92.52.92.6rxzrxz251.8501.3500.1601.9001.6000.1401.6501.9001.600351.3501.3500.1551.3501.1500.1351.1501.3501.200500.9800.9900.1551.0000.8600.1350.8701.0000.870700.6700.6700.1500.6900.5900.1300.6000.6900.610950.4900.5000.1500.5200.4300.1300.4500.5200.4501200.3900.4000.1450.4200.3400.1300.3700.4200.3601500.3100.3200.1450.3500.2800.1250.3000.3500.3001850.2500.2600.1450.2900.2200.1250.2600.2900.2502400.1950.2000.1400.2400.1750.1250.2100.2400.2103000.1550.1600.1400.2100.1400.1200.1850.2100.1904000.1200.1300.1400.1900.1150.1200.1650.1900.180
Other supplier products
|
|
|
Type W Four-Conductor Flat Portable Power Cable 2kVApplicationsThese flat parallel cables are designed for use on ACmining equipment,Website:, such... |
|
|
|
NF M 87-202 EGSFAPPLICATIONThese NF M 87-202 EGSF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units par... |
|
|
|
P5 or P5/P12 BFOU 0.6/1KV Fire Resistant NEK606 Power cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke,halog... |
|
|
|
Harmonized Code Industrial Cables H00V-DApplication and DescriptionThese high flexible eartd conductors are used for eartding of portable equipmen... |
|
|
|
Standards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed stranded copper,Website:, class 2 acco... |
供应产品
Same products