Type 2S 1.1/1.1KV & 3.3/3.3KV Individually Screened

Type 2S 1.1/1.1KV & 3.3/3.3KV Individually ScreenedApplicationsThese individually copper screened cables are used for wiring of machines or between machines and equipment wherea rubber cable is desired. These cables are also used for longwall lighting circuits,Website:, and may contain pilot and controlcores or twisted pair and screened cores.StandardsAS/NZS 1972:2006AS/NZS 1125AS/NZS 3808ConstructionConductorsStranded copper conductor.InsulationEPR.FillingElastomer centre filler.Pilot/Control CoresEPR covered and composite screened flexible stranded tinned copper conductor.IndividualComposite Screen (earth conductor)Tinned annealed copper braiding interwove with polyester yarn.SheathHeavy duty CPE sheath.Dimensions and WeightNumber of CoreNominal Conductor AreaStrand SizeInsulation ThicknessCore screenPilot ConductorNominal Sheath ThicknessNominal Overall DiameterNominal WeightStrand SizeAreaof ScreenNumber of PilotsStrand SizeThickness of Coveringmm²No/mmmmmmmm²No/mmmmmmmmkg/100mType 2S 1.1/1kV Individually Screened31077/0.401.20.27.93––1.822.16941077/0.401.20.27.94––1.823.093216126/0.401.20.29.02––1.822.081316126/0.401.20.29.03––1.823.4100416126/0.401.20.29.04––1.826.813531077/0.401.20.27.9330/0.201.01.822.587216126/0.401.20.29.0230/0.201.01.822.788316126/0.401.20.29.0330/0.201.01.827.7130325209/0.401.40.211.3330/0.201.01.829.2165335285/0.401.40.212.4330/0.201.01.831.6200350380/0.401.60.2517.5330/0.201.01.936.1260Type 2S 1.1/1kV Individually and Collectively Screened301.530/0.251.00.314.0–––1.932.6170Type 2S 3.3/3.3Kv Individually Screened31077/0.403.00.211.3330/0.251.01.828.9130316126/0.403.00.212.4330/0.251.01.831.3160325209/0.403.00.213.6330/0.251.01.934.8210335285/0.403.00.215.3330/0.251.02.037.8250350380/0.403.00.217.0330/0.251.02.141.3305370203/0.673.00.330.5330/0.251.02.246.8415395259/0.673.00.330.5330/0.251.02.349./0.673.00.447.5330/0.251.02.555.0620
Other supplier products
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9842ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
|
CAT 6 U/FTP 23AWG IEC60092ApplicationThese Cat6 U/FTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can support all... |
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 8kV ICEA S-75-381ApplicationsThese cables are designed for connections bet... |
|
|
|
(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9844ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |