450 750V XLPE Insulated, PVC Sheathed, Screened Power Cables (2-4 Cores)

450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (2-4 Cores) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design adapted to IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING450/750VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Filler, binder (if any): PP, PET, PVC Overall Screen: Copper tapeOuter Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation:  Max.90°C for XLPE250°C in short-circuit for 5secs max.Minimum bending radius: 8 x Overall DiameterCONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./Nominal Diameter of StrandsNominal Overall Diameter ConductorNominal Insulation ThicknessNominal Copper Tape ThicknessNominal Sheath ThicknessNominal Overall DiameterMax.Dc Resistance Of Conductor WeightKg/KM2x1.07/0.441.320.70.11.210.718.11722x1.57/0.531.590.70.11.311.312.11972x2.57/0.672.010.70.11.312.27.412392x4.07/0.852.550.70.11.313.44.613003x1.07/0.441.320.70.11.311.218.11943x1.57/O.531.590.70.11.311.812.12243x2.57/0,672.010.70.11.312.87.412763x4.07/0.852.550.70.11.314.14.613534x1.07/0.441.320.70.11.312.018.12244x1.57/0.531.590.70.11.412.712.12614x2.57/0.672.010.70.11.313.97.413264x4.07/0.852.550.70.11.315.34.61422Electrical PropertiesConductor Operating Temperature : 90°CAmbient Temperature :30°CCurrent-Carrying Capacities (Amp)Conductor cross- sectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3- phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3- phase a.c.mm2AAAAAAAAAAA1...Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.04646----1..


在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

450/750V SR Insulated fire resistant control cables (2-5 cores)(PH60) (CU/SR/LSZH 450/750V Class 2)Application:The cables are designed,Website:, ma...
Paper Insulated 11/11KV to AS/NZSApplicationsThese cables are used as HV feeder cables in fixed conditions.StandardsAS/NZS 1972:2006AS/NZS 1125AS/...
600/1000V XLPE Insulated,Website:, PVC Sheathed, Armoured Power Cables (2-5 Cores)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/SWA/PVC 600/1000V Class ...
Harmonized Code Industrial Cables H05V2-U/H07V2-U Application and DescriptionThese cables are for fixed protected installation inside appliances an...
UL Industrial Cables RHH or RHW-2 or USE-2,Website:, 600V, EPR / CSPApplication and DescriptionThese cables are designed for use in lighting and po...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes