.

600/1000V LSZH Sheathed, Armoured (2-4cores)

600/1000V LSZH Sheathed,Website:, Armoured ((2-4cores) Application:This range of screened cables drastically reduce interferences from electrical noise, especially in Variable Speed Drive (VSD) applications and are manufactured with fixed conductors.Standard:Basic design to IEC 60502-1; BS 6724FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING 600/1000VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound. Inner Sheath(optional): LSZH Compound Armouring(optional): Galvanized Steel WireOuter Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODE Insulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C250°C in short-circuit for 5s max. Minimum bending radius: 8 x Overall Diameter (unarmoured cable) 10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter Of StrandsNominal Insulation ThicknessUnarmouredArmouredNominal Overall DiameterApprox. WeightDiameter Under ArmourArmour Wire DiameterNominal Overall DiameterApprox. Weightmm²No./mmmmmmkg/kmmmmmmmkg/km2x1.57/0.530.710.01268.50.913.93502x2.57/0.670.710.81589.30.914.74002x47/0.850.711.920510.40.915.84752x67/1.040.713.026411.50.916.95602x107/1.350.714.937813.41.2519.58102x167/1.700.717.053415.51.2521.69802x257/2.140.920.465018.91.625.714102x357/2.520.922.788021.21.628.019303x1.57/0.530.710.51459.00.914.43903x2.57/0.670.711.41859.90.915.34503x47/0.850.712.524711.00.916.45403x67/1.040.713.832311.61.2517.77453x107/1.350.715.847414.31.2520.49503x167/1.700.718.068216.51.2523.012503x257/2.140.921.791020.21.627.018403x357/2.520.924.0118022.41.629.220503x50(S)19/1.781.025.5160024.21.631.225903x70(S)19/2.141.129.0224028.22.036.235603x95(S)19/2.521.133.5305031.72.040.145903x120(S)37/2.031.237.5380036.02.044.658103x150(S)37/2.251.440.5464039.52.553.569203x185(S)37/2.521.645.0587043.32.553.583403x240(S)61/2.251.750.5767048.42.559.0104503x300(S)61/2.521.857.0946054.42.565.4127003x400(S)61/2.852.063.01194557.82.570.0153264x1.57/0.530.711.316910.00.915.44304x2.57/0.670.712.322010.80.916.25054x47/0.850.713.629712.10.917.57104x67/1.040.715.039213.51.2519.68554x107/1.350.717.258515.71.2521.811204x167/1.700.719.785118.21.625.016004x257/2.140.923.9120022.41.629.221604x35(S)7/2.520.925.0160024.41.631.425604x50(S)19/1.781.028.0220028.01.635.231804x70(S)19/2.141.132.0305032.22.040.644904x95(S)19/2.521.137.0407036.02.044.654254x120(S)37/2.031.242.0591538.02.550.075504x150(S)37/2.251.446.0635042.82.553.085554x185(S)37/2.521.650.0789048.42.559.0105604x240(S)61/2.251.757.01040055.02.566.0131804x300(S)61/2.521.863.01281059.62.571.0161004x400(S)61/2.852.071.01586966.13.1579.4207154x500(S)61/3.202.278.02030074.63.1588.525347(S) - Sectoral Stranded ConductorsElectrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CUnarmoured Current-Carrying Capacities (Amp)Conductor cross- sectional areaReference method 4 (enclosed in conduit in thermally insulating wall etc)Reference method 3 (enclosed in conduit on a wall or in trunking etc)Reference method 1 (clipped direct)Reference method 11 (on a perforated cable tray, horizontal or vertical)Reference method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm²AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Size of conductor2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1...87.96.86.86.86.8104.74.74.7444162.92.92.92.52.52.5rxzrxzrxzrxzrxz251.851.850.311.901.850.1901.851.600.271.651.6000.1651.6001.6000.1901.600351.351.350.291.351.350.1801.351.150.251.150.1501.551.501.1500.1801.150500.991.000.291.050.990.1801.000.870.250.900.8600.1550.8700.8600.1800.870700.680.700.280.750.680.1750.710.600.240.650.5900.1500.6100.5900.1750.620950.490.510.270.580.490.1700.520.440.230.500.4300.1450.4500.4300.1700.4601200.390.410.260.480.390.1650.430.350.230.420.3400.1400.3700.3400.1650.3801500.320.330.260.430.320.1650.360.290.230.370.2800.1400.3100.2800.1650.3201850.250.270.260.370.260.1650.300.230.230.320.2200.1400.2600.2200.1650.2802400.190.210.260.330.200.1600.250.1850.220.290.1700.1400.2200.1700.1650.2403000.1550.1750.250.310.160.1600.220.1500.220.270.1400.1400.1950.1350.1600.2104000.120.1400.250.290.130.1550.200.1250.220.250.1100.1350.1750.1100.1600.1955000.0930.1200.250.280.1050.1550.1850.1000.220.240.0900.1350.1600.0880.1600.180Armoured  Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm²AAAAAAAA1..Voltage Drop (Per Amp Per Meter)Conductor cross-sectional area2-core cable d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c.3 or 4 cables, 3-phase a.c.In ducts or in groundIn ducts or in ground123456mm²mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.531.031.027.031.025.02.519.019.016.019.015.0412.012.010.012.09.767.97.96.87.96.5104.74.74.04.73.9162.92.92.52.92.6rxzrxz251.8501.3500.1601.9001.6000.1401.6501.9001.600351.3501.3500.1551.3501.1500.13501.1501.3501.200500.9800.9900.1551.0000.8600.1350.8701.0000.870700.6700.6700.1500.6900.5900.1300.6000.6900.610950.4900.5000.1500.5200.4300.1300.4500.5200.4501200.3900.40000.1450.4200.3400.1300.3700.4200.3601500.3100.3200.1450.3500.2800.1250.3000.3500.3001850.2500.2600.1450.2900.2200.1250.2600.2900.2502400.1950.2000.1400.2400.1750.1250.2100.2400.2103000.1550.1600.1400.2100.1400.1200.1850.2100.1904000.1200.1300.1400.1900.1150.1200.1650.1900.180

在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Three Core Medium Power Cable to VDE 0276Application:The three core cables are designed for distribution of electrical power with nominal voltage U...
Type W Two-Conductor Round Portable Power Cable 2kVApplicationsThese cables are designed for general use where baregrounding conductors are not req...
German Standard Industrial Cables NYCWYApplication and DescriptionNYCWY Power cables is for energy supply,Website:, preferably used for underground...
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 15kV ICEA S-75-381ApplicationsThese cables are designed for connections be...
UL Industrial Cables XHHW/CPE,Website:, 4-core, 600V,Type TC Power CableApplication and DescriptionXHHW/CPE, type TC Power Cable is used to supply ...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes