.

450/750V 600/1000V Mica+LSZH Insulated Power Cables (Single Core)

450/750V  600/1000V Mica+LSZH Insulated fire resistant Power Cables (Single Core)(CU/MGT+LSZH 450/750V Class 2)(CU/MGT+LSZH 600/1000V Class 2)Application:This cable is used in fire extinguishing systems,Website:, sprinklers, control panels, and exit lights in high-rise buildings, hotels, hospitals, sub-ways, and public facilities.STANDARDS:Basic design to BS 7211FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)System circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING450/750V & 600/1000VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2Fire Barrier: Mica glass tapeInsulation: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation Colour: Orange (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -30°C – +90°CTemperature range during installation (mobile state): -20°C – +50°CMinimum bending radius: 6 x Overall DiameterElectrical PROPERTIESDielectric test:600/1000V: 3500 V r.m.s. x 5’ (core/core);450/750V: 2500 V r.m.s. x 5’ (core/core)Insulation resistance20 MΩ x km (at 20°C)Short circuit temperature250°CCONSTRUCTION PARAMETERSConductor450/750V600/1000VNominal Cross Section AreaNo./ Nominal Diameter of trandsNominalInsulationThicknessNominalOverallDiameterApprox.WeightNominalInsulationThicknessNominalOverallDiameterApprox.Weightmm2No./mmmmmmkg/kmmmmmkg/km1.57/0.530.73.5250.83.8302.57/0.670.84.1350.84.24047/0.850.84.65215.37067/1.040.85.2721696107/1.3516.512016.6130167/1.7017.618017.7200257/2.141.292751.29.1290357/2.521.210.23701.210.33905019/2.521.411.85001.411.95207019/2.141.413.47001.413.57309519.2.521.615.89801.615.999015037/2.521.818.815001.818.9152018537/2..2190024037/2.522.225.725002.225.8255030037/2.522.428.631402.428.8315040061/2.852.63240002.632.2400050061/3.202.835.550002.835./2.522.839.563002.839.76360Electrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)ConductorcrosssectionareaReference Method 4(enclosed in conduitin thermally insulatingwall etc)ReferenceMethod 3(enclosed inconduit on a wall or in trunkingetc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal orvertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables,single-phasea.c. or d.c.3 or 4cables,3-phasea.c.2cables,single-3 or 4cables,3-phasea.c.2 cables,single-phasea.c. or d.c. flatand touching3 or 4cables,3-phasea.c. flatandtouchingor trefoil2 cables,single-phase a.c.or d.c. or flat and touching3 or 4cables,3-phasea.c. flatand touchingor trefoil2 cables,single-phasea.c. or d.c. or 3 cables threephase2 cables,single-phasea.c. or d.c. or3 cables threephase3 cables,trefoil3-phasephase a.c.phase a.c.a.c. ord.cmm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)NominalCrossSectionArea2 cablesd.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3and 4 (enclosedin conduit etc,in or on a wall)Ref. Methods 1and 11 (clippeddirect or on traystouching)Ref. Methods 3and 4 (enclosedin conduit etc,in or on a wall)Ref. Methods 1,Ref. Methods 1 and 1111 and 12(in trefoil)(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.531 31  27  27  27  27 2.519 19  16  16  16  16 433 12  10  10  10  10 67.8 7.9  6.8  6.8  6.8  6.8 104.7 4.7  4.7  4  4  4 162.9 2.9  2.9  2.5  2.5  2.5   rxzrxzrxzrxzrxz251.851.60.311.91.850.191.851.60.271.651.60.1651.61.60.191.6351.351.350.291.351.350.181.351.150.251.151.150.1551.51.150.181.15500.9910.291.050.990.1810.870.250.90.860.1550.870.860.180.87700.680.70.280.750.680.1750.710.60.240.650.590.150.610.590.1750.62950.490.510.270.580.490.170.520.440.230.50.430.1450.450.430.170.461200.390.410.260.480.390.1650.430.350.230.420.340.140.370.340.1650.381500.320.330.260.430.320.1650.360.290.230.370.280.140.310.280.1650.321850.250.270.260.370.260.1650.30.230.230.320.220.140.260.220.1650.282400.190.210.260.330.20.160.250.1850.220.290.170.140.220.170.1650.243000.1550.1750.250.310.160.160.220.150.220.270.140.140.1950.1350.160.214000.120.140.250.290.130.1550.20.1250.220.250.110.1350.1750.110.160.1955000.0930.120.250.280.1050.1550.1850.10.220.240.090.1350.160.0880.160.186300.0720.10.250.270.0860.1550.1750.0880.210.230.0740.1350.150.0710.160.17Note : r = conductor resistance at operating temperaturex = reactancez = impedance

在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

0.6/1KV SCP,Website:, SYPStandards:JISC 3410-1999IEC 60332-1CABLE CONSTRUCTIONConductorSBunched tinned annealed stranded copper, class 5 according ...
Type SHD-GC Three-Conductor Portable Power Cable,Website:, CPE Jacket 2kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for applica...
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multipair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBasic desig...
P1 or P1/P8 RFOU/TFOU 0.6/1KV NEK606 Power cableApplications :Marine cables are flame retardant,Website:, low smoke, halogen free and mud resistant...
German Standard Industrial Cables LiYW Application and DescriptionThese thermal insulated wires are ideal for use in power current installation,Web...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes