N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605

N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605ApplicationsThese cables are used for the connection of mobile operatingequipment,Website:, in mines and undergroundexcavations with hazardous environments,in stationary operation, e.g.high-voltage transformers in mining andtunnelling.StandardsVDE 0250 Part 605ConstructionConductorsFlexible strandedcopper conductor, class 5 according to DIN VDE 0295.InsulationEPR compound type 3GI3.Electrical Field ControlInner and outer semiconductive layer ofsemiconductive rubber, for 6 kV outersemiconductive layer only.Pilot CoresStranded copper conductor with EPR insulation.Earth ConductorSpiral ofcopper wiresover the outer semi-conductivelayer of the cores.InnerSheathPVC compound type YM5.Monitoring ConductorConductive tape serving and overallconcentric Cu wire spinning.Intermediate SheathPVCcompound type YM5.ArmourBraid of galvanized steel wires.Outer SheathPVC compound type YM5.Dimensions and Weight3.6/6kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL49.053.041903×35+3×16/3E+3×2.5ST+UEL52.056.048003×50+3×25/3E+3×2.5ST+UEL55.059.056003×70+3×35/3E+3×2.5ST+UEL59.063.066503×95+3×50/3E+3×2.5ST+UEL63.067.079406/10kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL55.0.58.053003×35+3×16/3E+3×2.5ST+UEL58.061.059103×50+3×25/3E+3×2.5ST+UEL61.065.067903×70+3×35/3E+3×2.5ST+UEL65.069.078603×95+3×50/3E+3×2.5ST+UEL68.073.091808.7/15kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL58.062.068103×35+3×16/3E+3×2.5ST+UEL61.065.078503×50+3×25/3E+3×2.5ST+UEL64.768.791303×70+3×35/3E+3×2.5ST+UEL67.971.9107503×95+3×50/3E+3×2.5ST+UEL72.476.41229012/20kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL62.366.387903×35+3×16/3E+3×2.5ST+UEL65.369.399303×50+3×25/3E+3×2.5ST+UEL69.073.0113603×70+3×35/3E+3×2.5ST+UEL72.276.2131003×95+3×50/3E+3×2.5ST+UEL76.880.814750
Other supplier products
|
|
|
Fire resistant FTP Cat3 Data Cables FR-CAT3FTP 4P22FRApplication:The cables are desgined for structure wiring,Website:, compatible with all known c... |
|
|
|
German Standard Industrial Cables LiY / LiYv / LiYv-tApplication and DescriptionThese PVC insulated stranded hook-up wires are employed in telecomm... |
|
|
|
Type 241 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are designed for various uses,Website:, including main feeder cable for continuous mine... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8333ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
PE Insulated,Website:, LSZH Sheathed & Overall Screened, Armoured Instrumentation Cables (Single Pair)RE-2Y(St)HSWAH 90°C / 300VSTANDARDSBasic des... |
供应产品