N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605

N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605ApplicationsThese cables are used for the connection of mobile operatingequipment,Website:, in mines and undergroundexcavations with hazardous environments,in stationary operation, e.g.high-voltage transformers in mining andtunnelling.StandardsVDE 0250 Part 605ConstructionConductorsFlexible strandedcopper conductor, class 5 according to DIN VDE 0295.InsulationEPR compound type 3GI3.Electrical Field ControlInner and outer semiconductive layer ofsemiconductive rubber, for 6 kV outersemiconductive layer only.Pilot CoresStranded copper conductor with EPR insulation.Earth ConductorSpiral ofcopper wiresover the outer semi-conductivelayer of the cores.InnerSheathPVC compound type YM5.Monitoring ConductorConductive tape serving and overallconcentric Cu wire spinning.Intermediate SheathPVCcompound type YM5.ArmourBraid of galvanized steel wires.Outer SheathPVC compound type YM5.Dimensions and Weight3.6/6kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL49.053.041903×35+3×16/3E+3×2.5ST+UEL52.056.048003×50+3×25/3E+3×2.5ST+UEL55.059.056003×70+3×35/3E+3×2.5ST+UEL59.063.066503×95+3×50/3E+3×2.5ST+UEL63.067.079406/10kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL55.0.58.053003×35+3×16/3E+3×2.5ST+UEL58.061.059103×50+3×25/3E+3×2.5ST+UEL61.065.067903×70+3×35/3E+3×2.5ST+UEL65.069.078603×95+3×50/3E+3×2.5ST+UEL68.073.091808.7/15kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL58.062.068103×35+3×16/3E+3×2.5ST+UEL61.065.078503×50+3×25/3E+3×2.5ST+UEL64.768.791303×70+3×35/3E+3×2.5ST+UEL67.971.9107503×95+3×50/3E+3×2.5ST+UEL72.476.41229012/20kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL62.366.387903×35+3×16/3E+3×2.5ST+UEL65.369.399303×50+3×25/3E+3×2.5ST+UEL69.073.0113603×70+3×35/3E+3×2.5ST+UEL72.276.2131003×95+3×50/3E+3×2.5ST+UEL76.880.814750
Other supplier products
|
|
|
150/250V Mica Tape + HEPR Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair)Application... |
|
|
|
Flame Retardant RS485 Databus Cables Application:Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol,Website:, suitable ... |
|
|
|
300V Mica+LSZH Insulated & LSZH Sheathed Fire Alarm CablesJE-H(St)H…Bd FE180 E90. (CU/MICA+LSZH/OS/LSZH 300V Class 1 )JE-H(St)H…Bd FE180 E90 BMK* (... |
|
|
|
Harmonized Code Industrial Cables H05Z-U/H07Z-U/H07Z-RApplication and DescriptionThese cables are designed for tde internal wiring of switchboards ... |
|
|
|
German Standard Industrial Cables Li2YCY PiMFApplication and DescriptionLi2YCY PiMF is particularly suitable for wiring data systems and controls i... |
供应产品
Same products