N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605

N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605ApplicationsThese cables are used for the connection of mobile operatingequipment,Website:, in mines and undergroundexcavations with hazardous environments,in stationary operation, e.g.high-voltage transformers in mining andtunnelling.StandardsVDE 0250 Part 605ConstructionConductorsFlexible strandedcopper conductor, class 5 according to DIN VDE 0295.InsulationEPR compound type 3GI3.Electrical Field ControlInner and outer semiconductive layer ofsemiconductive rubber, for 6 kV outersemiconductive layer only.Pilot CoresStranded copper conductor with EPR insulation.Earth ConductorSpiral ofcopper wiresover the outer semi-conductivelayer of the cores.InnerSheathPVC compound type YM5.Monitoring ConductorConductive tape serving and overallconcentric Cu wire spinning.Intermediate SheathPVCcompound type YM5.ArmourBraid of galvanized steel wires.Outer SheathPVC compound type YM5.Dimensions and Weight3.6/6kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL49.053.041903×35+3×16/3E+3×2.5ST+UEL52.056.048003×50+3×25/3E+3×2.5ST+UEL55.059.056003×70+3×35/3E+3×2.5ST+UEL59.063.066503×95+3×50/3E+3×2.5ST+UEL63.067.079406/10kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL55.0.58.053003×35+3×16/3E+3×2.5ST+UEL58.061.059103×50+3×25/3E+3×2.5ST+UEL61.065.067903×70+3×35/3E+3×2.5ST+UEL65.069.078603×95+3×50/3E+3×2.5ST+UEL68.073.091808.7/15kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL58.062.068103×35+3×16/3E+3×2.5ST+UEL61.065.078503×50+3×25/3E+3×2.5ST+UEL64.768.791303×70+3×35/3E+3×2.5ST+UEL67.971.9107503×95+3×50/3E+3×2.5ST+UEL72.476.41229012/20kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo. ×mm²mmmmkg/km3×25+3×16/3E+3×2.5ST+UEL62.366.387903×35+3×16/3E+3×2.5ST+UEL65.369.399303×50+3×25/3E+3×2.5ST+UEL69.073.0113603×70+3×35/3E+3×2.5ST+UEL72.276.2131003×95+3×50/3E+3×2.5ST+UEL76.880.814750
Other supplier products
|
|
|
250V [FA-] TTY,Website:, TTYC, TTYCY [FA-] TTPY, TTPYC, TTPYCYStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONCo... |
|
|
|
NTSCGEWOEU Flexible Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used as power supply or connection cables for large... |
|
|
|
S4 or S4/S8 BFOU(c) 250V Armour& Collective Shielding fire resistant NEK606 Instrumentation cableApplications :These cables are fire resistant,Webs... |
|
|
|
NSSHOEU-O/J 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812ApplicationsThese cables are designed for the connection of mobile equipment and mac... |
|
|
|
Multicore Unscreened Armoured Cables-Belden Equivalent 28538ApplicationsThese multicore unscreened armoured cables are Type MC Metal Clad cables.Co... |