Type 241 1.1 To 11KV To AS/NZS 1802

Type 241 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are designed for various uses,Website:, including main feeder cable for continuous miners, pump cable, and power supply cable. Overall semiconductive screen provides protective earth contact for any object breaching the sheath prior to contact with power conductors.StandardsAS/NZS 1802:2003AS/NZS 1125AS/NZS 3808AS/NZS 5000.1Construction3×ConductorsFlexible stranded tinned annealed copper conductor.Conductor ScreenSemiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).InsulationEPR.Insulation ScreenSemiconductive elastomer.Cradle SeparatorSemiconductive PCP.Overall Core ScreenSemiconductive PCP filling and covering.3×Interstitial Earth ConductorSemiconductive PCP covered flexible stranded tinned copper conductor.1×Central Extensible PilotEPR covered flexible stranded tinned copper conductor.Textile ReinforcementOpen-weave braid reinforcement.SheathHeavy duty PCP sheath.Heavy duty CPE/CSP sheath can be offered upon request.Dimensions and WeightNominal Conductor AreaStrandSizeInsulation ThicknessEarth ConductorPilot ConductorThickness of Sheath IncludingSC PCPLayerNominal Overall DiameterNominal WeightStrandSizeThickness of CoveringStrandSizeThickness of Coveringmm2No/mmmmNo/mmmmNo/mmmmmmmmkg/100mType 241.1684/0.301.518/0.301.024/0.200.83.828.51061077/0.401.527/0.301.024/0.200.83.831.112716126/0.401.642/0.301.024/0.200.83.934.116425209/0.401.666/0.301.024/0.200.84.237.920835285/0.401.690/0.301.024/0.200.84.441.225450380/0.401.7120/0.301.040/0.200.84.945.932870203/0.671.839/0.671.040/0.200.85.352.248095259/0.672.039/0.671.040/0.200.85.856.7600120336/0.672.142/0.671.240/0.200.86.362.7710150427/0.672.354/0.671.240/0.200.86.768.3865185518/0.672.563/0.671.440/0.200.87.374./0.672.877/0.671.440/0.200.88.083./0.673.098/0.671.440/0.200.88.791.21600Type 241.316126/0.403.042/0.301.024/0.200.85.043.824925209/0.403.066/0.301.024/0.200.85.347.731535285/0.403.090/0.301.024/0.200.85.651.137650380/0.403.0120/0.301.240/0.200.86.055.245070203/0.673.039/0.671.240/0.200.86.460.357695259/0.673.048/0.671.240/0.200.86.863.8675120336/0.673.060/0.671.240/0.200.87.269.1810150427/0.673.077/0.671.240/0.200.87.673.8952185518/0.673.091/0.671.440/0.200.88.079./0.673.0112/0.671.440/0.200.88.686./0.673.0144/0.671.440/0.200.89.192.61660Type 241.616126/0.405.042/0.301.424/0.200.86.154.936525209/0.405.066/0.301.424/0.200.86.458.844035285/0.405.090/0.301.424/0.200.86.762.250950380/0.405.0120/0.301.440/0.200.87.166.259270203/0.675.039/0.671.440/0.200.87.471.272795259/0.675.048/0.671.440/0.200.87.974.8835120336/0.675.060/0.671.440/0.200.88.380.2990150427/0.675.077/0.671.440/0.200.88.684./0.675.091/0.671.440/0.200.89.090./0.675.0119/0.671.440/0.200.89.696./0.675.0156/0.671.440/0.200.810.2103.61900Type 241.1125209/0.407.666/0.301.824/0.200.87.873.264535285/0.407.690/0.301.824/0.200.88.176.672450380/0.407.6120/0.301.840/0.200.88.580.682570203/0.677.639/0.671.840/0.200.88.985.797595259/0.677.648/0.671.840/0.200.89.389./0.677.660/0.671.840/0.200.89.794./0.677.677/0.671.840/0.200.810.098./0.677.691/0.671.840/0.200.810.4104.21610
Other supplier products
|
|
|
Armoured Cat 6 S/FTP 23AWG IEC60092ApplicationThese Cat6 S/FTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can su... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Single Triple)RE-2Y(St)HSWAH 70°C / 300 VSTANDARDSBasic d... |
|
|
|
Multicore Unscreened Armoured Cables-Belden Equivalent 28538ApplicationsThese multicore unscreened armoured cables are Type MC Metal Clad cables.Co... |
|
|
|
(N)SHOEU 0.6/1kV Flexible cable VDE 0250 Part 812ApplicationsThese cables are designed for use in open cast miningfactories for laying of excavator... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8302ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
供应产品