Type 455 3.3 To 33KV To AS/NZS 2802

Type 455 3.3 to 33KV to AS/NZS 2802ApplicationsThese cables are designed with reduced insulation and sheath thickness,Website:, no cradle, 2 earth and 1 pilotcore (each earth and pilot are the same size) in the outer interstices. These cablesare suitable for reeling and trailingapplications where minimal diameter and mass is desired, particularly suited to stacker-reclaimer applications.StandardsAS/NZS 2802:2000AS/NZS 1125AS/NZS 3808AS/NZS 5000.1Construction3×ConductorsFlexible stranded tinned annealed copper conductor.Conductor ScreenSemiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).InsulationEPR.Insulation ScreenSemiconductive elastomer.FillerElastomer centre filler.2×Interstitial Earth ConductorCSP insulated flexible stranded tinned copper conductor.1×Interstitial PilotEPR covered flexible stranded tinned copper conductor.Textile ReinforcementOpen-weave braid reinforcement.SheathExtra-heavy duty PCP sheath.Extra-heavy duty CPE/CSP sheath can be offered upon request.Dimensions and WeightNominal Conductor AreaStrand SizeInsulation ThicknessPilot/Earth ConductorThickness of SheathNominal Overall DiameterNominal WeightStrand SizeThickness of Coveringmm2No/mmmmNo/mmmmmmmmkg/100mType 455.3 Class116126/0.402.2120/0.301.44.239.422425209/0.402.2120/0.301.44.543.328135285/0.402.2120/0.301.44.846.733650380/0.402.4183/0.301.45.351.942470203/0.672.454/0.671.45.757.055695259/0.672.470/0.671.66.160.5646120336/0.672.484/0.671.66.465.6786150427/0.672.4112/0.671.66.569.7931185518/0.672.4132/0.671.66.674./0.672.4168/0.671.66.880./0.672.4228/0.671.66.986.31600Type 455.6 Class116126/0.403.0120/0.301.44.743.926625209/0.403.0120/0.301.65.047.833235285/0.403.0120/0.301.65.351.338750380/0.403.0183/0.301.65.655.146670203/0.673.054/0.671.66.060.359795259/0.673.070/0.671.86.363.5692120336/0.673.084/0.671.86.568.5826150427/0.673.0112/0.671.86.672.6977185518/0.673.0132/0.671.86.777./0.673.0168/0.671.86.983./0.673.0228/0.671.87.089.11652Type 455.11 Class116126/0.405.0120/0.302.05.855.139225209/0.405.0120/0.302.06.159.046235285/0.405.0120/0.302.06.362.252750380/0.405.0183/0.302.06.465.660770203/0.675.054/0.672.06.570.274295259/0.675.070/0.672.26.773.2837120336/0.675.084/0.672.26.877.9982150427/0.675.0112/0.672.26.982./0.675.0132/0.672.27.086./0.675.0168/0.672.27.292.81553Type 455.22 Class116126/0.407.6120/0.302.56.668.557825209/0.407.6120/0.302.56.671.765335285/0.407.6120/0.302.56.774.771950380/0.407.6183/0.302.56.878.281070203/0.677.654/0.672.57.082.995695259/0.677.670/0.672.57.185./0.677.684/0.672.57.290./0.677.6112/0.672.57.394./0.677.6132/0.672.57.499.31564Type 455.33 Class116126/0.4010.5120/0.302.57.083.082225209/0.4010.5120/0.302.57.186.492035285/0.4010.5120/0.302.57.289.499350380/0.4010.5183/0.302.57.392.8109270203/0.6710.554/0.672.57.497.4125495259/0.6710.570/0.672.57.6100./0.6710.584/0.672.57.7105./0.6710.5112/0.672.57.8109.21720
Other supplier products
|
|
|
Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, CPE Jacket 8kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for a... |
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Jacket, 15kV to ICEA S-75-381ApplicationsThese cables are designed for connections... |
|
|
|
Industrial Cables H07V-KApplication and DescriptionThese are not suitable to be installed for laying in tubes,Website:, under and surface mounting ... |
|
|
|
450/750V LSZH Sheathed (multicore) Application:The cables are mainly used in power stations,Website:, mass transit underground passenger systems, a... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Individual & Overall Screened, Armoured Instrumentation Cables (Multitriple)RE-2Y(St)HSWAH-TiMF 70°C / 300 VS... |
供应产品