.

Type 455 3.3 To 33KV To AS/NZS 2802

Type 455 3.3 to 33KV to AS/NZS 2802ApplicationsThese cables are designed with reduced insulation and sheath thickness,Website:, no cradle, 2 earth and 1 pilotcore (each earth and pilot are the same size) in the outer interstices. These cablesare suitable for reeling and trailingapplications where minimal diameter and mass is desired, particularly suited to stacker-reclaimer applications.StandardsAS/NZS 2802:2000AS/NZS 1125AS/NZS 3808AS/NZS 5000.1Construction3×ConductorsFlexible stranded tinned annealed copper conductor.Conductor ScreenSemiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).InsulationEPR.Insulation ScreenSemiconductive elastomer.FillerElastomer centre filler.2×Interstitial Earth ConductorCSP insulated flexible stranded tinned copper conductor.1×Interstitial PilotEPR covered flexible stranded tinned copper conductor.Textile ReinforcementOpen-weave braid reinforcement.SheathExtra-heavy duty PCP sheath.Extra-heavy duty CPE/CSP sheath can be offered upon request.Dimensions and WeightNominal Conductor AreaStrand SizeInsulation ThicknessPilot/Earth ConductorThickness of SheathNominal Overall DiameterNominal WeightStrand SizeThickness of Coveringmm2No/mmmmNo/mmmmmmmmkg/100mType 455.3 Class116126/0.402.2120/0.301.44.239.422425209/0.402.2120/0.301.44.543.328135285/0.402.2120/0.301.44.846.733650380/0.402.4183/0.301.45.351.942470203/0.672.454/0.671.45.757.055695259/0.672.470/0.671.66.160.5646120336/0.672.484/0.671.66.465.6786150427/0.672.4112/0.671.66.569.7931185518/0.672.4132/0.671.66.674./0.672.4168/0.671.66.880./0.672.4228/0.671.66.986.31600Type 455.6 Class116126/0.403.0120/0.301.44.743.926625209/0.403.0120/0.301.65.047.833235285/0.403.0120/0.301.65.351.338750380/0.403.0183/0.301.65.655.146670203/0.673.054/0.671.66.060.359795259/0.673.070/0.671.86.363.5692120336/0.673.084/0.671.86.568.5826150427/0.673.0112/0.671.86.672.6977185518/0.673.0132/0.671.86.777./0.673.0168/0.671.86.983./0.673.0228/0.671.87.089.11652Type 455.11 Class116126/0.405.0120/0.302.05.855.139225209/0.405.0120/0.302.06.159.046235285/0.405.0120/0.302.06.362.252750380/0.405.0183/0.302.06.465.660770203/0.675.054/0.672.06.570.274295259/0.675.070/0.672.26.773.2837120336/0.675.084/0.672.26.877.9982150427/0.675.0112/0.672.26.982./0.675.0132/0.672.27.086./0.675.0168/0.672.27.292.81553Type 455.22 Class116126/0.407.6120/0.302.56.668.557825209/0.407.6120/0.302.56.671.765335285/0.407.6120/0.302.56.774.771950380/0.407.6183/0.302.56.878.281070203/0.677.654/0.672.57.082.995695259/0.677.670/0.672.57.185./0.677.684/0.672.57.290./0.677.6112/0.672.57.394./0.677.6132/0.672.57.499.31564Type 455.33 Class116126/0.4010.5120/0.302.57.083.082225209/0.4010.5120/0.302.57.186.492035285/0.4010.5120/0.302.57.289.499350380/0.4010.5183/0.302.57.392.8109270203/0.6710.554/0.672.57.497.4125495259/0.6710.570/0.672.57.6100./0.6710.584/0.672.57.7105./0.6710.5112/0.672.57.8109.21720

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812
NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812 NSSHOEU .../3E + ST 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812ApplicationsThese cables are designed for the connection of mobile equipment...
Breakout Fiber Cable
Breakout Fiber Cable Breakout Fiber CableApplicationThese optical fiber cables are designed to data transmission in ship and specially in cruise ship where low smoke,We...
150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation Control Cables (Multicore)
150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation Control Cables (Multicore) 50/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore)ApplicationThese armour...
Armoured Cat 5e SF/UTP 24AWG
Armoured Cat 5e SF/UTP 24AWG Armoured Cat 5e SF/UTP 24AWG IEC60092ApplicationThese Cat5e SF/UTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, ca...
150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Unarmoured Fire Resistant Instrumentation Control Cables
150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Unarmoured Fire Resistant Instrumentation Control Cables Fire Resistant 150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Individually Screened Unarmoured Instrumentation & Control CablesApplication:T...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes