H07RN-F/A07RN-F 450/750V Harmonized Rubber Cables

H07RN-F/A07RN-F 450/750V Harmonized Rubber CablesApplicationsThese cables are designed for the connection of heating units,Website: tools, mobile equipmentand machines, e.g. vulcanisation plates,hand-operated equipment,transportable motors etc., undernormal mechanical loads in dry anddamp areas, outdoors and in explosionhazard areas, as well as in industrialand agricultural applications and onbuilding sites.StandardsDIN VDE 0282 Part1 and Part 4HD 22.1HD 22.4ConstructionConductorsStrandedcopper conductor, class 5 according to DIN VDE 0295/HD 383 S2.InsulationRubbertype EI4 according to DIN VDE 0282 Part 1/HD 22.1.Inner Sheath(for ≥ 10 mm² ormore than 5 cores)NR/SBR rubbertype EM1.Outer SheathCR/PCP rubber type EM2.Dimensions and Weight:Number of Cores×Nominal Cross SectionInsulation ThicknessThickness of Inner SheathThickness of Outer SheathMinimum Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmmmmmmmkg/km1×1.50.8-1.45.76.7602×1.50.8-1.58.510.51203G1.50.8-1.69.211.21704G1.50.8-1.710.212.52105G1.50.8-1.811.213.52607G1.50.81.01.614.017.036012G1.50.81.21.717.620.551519G1.50.81.42.120.726.379524G1.50.81.42.124.328.59201×2.50.9-1.46.37.5752×2.50.9-1.710.212.51703G2.50.9-1.810.913.02304G2.50.9-1.912.114.52905G2.50.9-2.013.316.03607G2.50.91.11.717.020.051012G2.50.91.21.920.623.574019G2.50.91.52.224.430.9119024G2.50.91.62.328.833.015251×41.0-1.57.28.51002×41.0-1.811.814.51953G41.0-1.912.715.03054G41.0-2.014.017.04005G41.0-2.215.619.05051×61.0-1.67.99.51302×61.0-2.013.116.02853G61.0-2.114.117.03804G61.0-2.315.719.05505G61.0-2.517.521.06601×101.2-1.89.511.51952×101.21.21.917.721.55653G101.21.32.019.122.57154G101.21.42.020.924.58755G101.21.42.222.927.010951×161.2-1.910.813.02802×161.21.32.020.223.57953G161.21.42.121.825.510404G161.21.42.223.828.012805G161.21.52.426.431.016101×251.4-2.012.715.04054G251.41.62.228.933.018905G251.41.72.732.036.023351×351.4-2.214.317.05454G351.41.72.732.536.525055G351.41.82.835.039.527181×501.6-2.416.519.57304G501.61.92.937.742.033505G501.62.13.141.046.038041×701.6-2.618.622.09554G701.62.03.242.747.047851×951.8-2.820.824.011354G951.82.33.648.454.060901×1201.8-3.022.826.515604G1201.82.43.653.059.075505G1201.82.84.059.065.082901×1502.0-3.225.229.019254G1502.02.63.958.064.084951×1852.2-3.427.631.522304G1852.22.84.264.071.098501×2402.4-3.530.635.029451×3002.6-3.633.538.034951×6303.0-4.145.551.07020
Other supplier products
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8306ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
Industrial Cables H07V-KApplication and DescriptionThese are not suitable to be installed for laying in tubes,Website:, under and surface mounting ... |
|
|
|
Fire Resistant 150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Armoured Instrumentation & Control CablesApplication:The... |
|
|
|
Belden8355
Website: |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Individual & Overall Screened, Armoured Instrumentation Cables (Multitriple)RE-2Y(St)HSWAH-TiMF 70°C / 300 VS... |
供应产品
Same products