300 500V PVC Insulated, PVC Sheathed Power Cables (2-5 Cores)
300/500V PVC Insulated,Website:, PVC Sheathed Power Cables (2-5 Cores)05VV-K (CU/PVC/PVC 300/500V Class 5)BS Code: 3182Y/3183Y/3184Y/3185YHAR Code: H05VV-FApplication:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design to BS EN formerly BS 6500)Fire Performance:Flame Retardance (Single Vertical Wire Test) EN 60332-1-2Voltage Rating:300/500VConductorFlexible copper wire according to EN 60228 class 5.InsulationPVC type TI 2 according to EN 50363-3.FillingFor circular cable having two cores, the space between the cores shall be filled either by separate fillers or by the sheath filling the interstices. For circular cables with three, four or five cores, a centre filler may be used.Outer SheathPVC type TM 2 according to EN 50363-4-1. A tape may be applied around the core assembly before application of the sheath.Sheath OptionUV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.Colour CodeInsulation ColourCables and cords with a green-and-yellow coresNo. of coresColour of coresbProtectiveLive3 CoresYellow/GreenBlueBrown4 CoresYellow/Green-BrownBlackGrey4 CoresaYellow/GreenBlueBrownBlack5 CoresYellow/GreenBlueBrownBlackGreya For certain applications only.b In this table an uninsulated concentric conductor, such as a metallic sheath, armour or screen wire, is not regarded as a core. A concentric conductor is identified by its position and, therefore, need not be identified by colour.Cables and cords without a green-and-yellow coresNo. of coresColour of coresb2 CoresBlueBrown3 Cores-BrownBlackGrey3 CoresaBlueBrownBlack4 CoresBlueBrownBlackGrey5 CoresBlueBrownBlackGreyBlacka For certain applications only.b In this table an uninsulated concentric conductor, such as a metallic sheath, armour or screen wire, is not regarded as a core. A concentric conductor is identified by its position and, therefore, need not be identified by colour.Sheath Colour: Black (other colors upon request)Physical And Thermal PropertiesMaximum temperature range during operation (PVC)60°CMaximum short circuit temperature (5 Seconds)150°CMinimum bending radiusUp to 12mm²: 3 x overall diameterAbove 12mm²: 4 x overall diameterConstruction ParametersNo. of Core X Cross SectionNominal Insulation ThicknessNominal Sheath ThicknessMaximum Overall DiameterApprox. WeightNoxmm2mmmmmmkg/km2x0.750.60.87.2572x1.00.60.87.5652x1.50.70.88.6872x2.50.81.010.61342x40.81.112.11743x0.750.60.87.6683x1.00.60.88.0793x1.50.70.99.41113x2.50.81.111.41693x40.81.213.12334x0.750.60.88.3844x1.00.60.99.01014x1.50.71.010.51424x2.50.81.112.52114x40.81.214.32925x0.750.60.99.31065x1.00.60.99.81235x1.50.71.111.61765x2.50.81.213.92625x40.81.416.1369Electrical PropertiesCurrent-Carrying Capacities (Amp) according to BS7671:2008 table 4F3AConductor cross-sectional areaSingle-phase a.c.Three-phase a.c.mm2AA0.5330.75661.010101.516162.5252043225Voltage Drop (Per Amp Per Meter) according to BS7671:2008 table 4F3BConductor cross-sectional aread.c. or single-phase a.c.Three-phase a.c.mm2mV/A/mmV/A/m0.593800.7562541.046401.532272.5191641210
Other supplier products
|
|
300/500V PVC Insulated,Website:, PVC Sheathed Power Cables (2-5 Cores)05VV-K (CU/PVC/PVC 300/500V Class 5)BS Code: 3182Y/3183Y/3184Y/3185YHAR Code:... |
|
|
UL Industrial Cables XHHW/PVC Jacket,Website:, Power Cable, CT RatedApplication and DescriptionXHHW/PVC conductors are primarily used in conduit, c... |
|
|
VDE Standard Industrial Cables H07RN8-FApplication and DescriptionThese cables particularly for use in fresh water up to 10 m depth with a maximum ... |
|
|
German Standard Industrial Cables LiYCYApplication and DescriptionLiYCY screened cables are suitable for flexible use witd free movement,Website:, ... |
|
|
450/750V LSZH Sheathed,Website:, Screened (2-4cores) Application:The cables are mainly used in power stations, mass transit underground passenger s... |
供应产品