.

PE Insulated, LSZH Sheathed, Overall Screened And Armoured Instrumentation Cables (Single Triple)

PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Single Triple)RE-2Y(St)HSWAH 70°C / 300 VSTANDARDSBasic design to EN50288-7APPLICATION:These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petr°Chemistry industry plants, power plants, natural gas and petroluem plants, etc...These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ;CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ;CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil ResistanceICEA S-73-532**Note: Asterisk * denotes superseded standard, **Test temperature +60°C, duration 4h. Retention: min 60% of tensite strength/min. 60% of elongation.VOLTAGE RATING300VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:PE compound, EN 50290. 2-23.Pair:Two conductors twisted to form a pairLay-up:Pairs laid up in layers of optimum pitchSeparator:Polyester tapeOverall Screen:Aluminium/polyester tape with tinned copper drain wire, 0.5mm2Inner sheath:LSZH compound, EN 50290-2-27Armour:Galvenized round steel wire, EN 10257-1Outer Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / White / Red, continuously numbered on white core(1, 2..)for multitriples.Outer Sheath:Black or blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30°C – +70°CTemperature Range During Installation (Mobile State):-5°C – +50°CMinimum Bending Radius:10 X Overall DiameterCONSTRUCTION PARAMETERSCable CodeRE-2Y(St)HSWAHNo. of Triplesx3xCross SectionNominalInsulationThick-nessNominalInnerSheathThick-nessNominal OverallDiameterOverInnerSheathNominalArmourWireDiameterNominalOuterSheathThick-nessNominal Overall DiameterApprox.WeightNo.x3xmm2mmmmmmmmmmmmkg/kmRE-2Y(St)HSWAH 1T0.51x3x0.500.350.85.40.91.39.8200RE-2Y(St)HSWAH 1T0.751x3x0.750.380.96.10.91.310.5220RE-2Y(St)HSWAH 1T1.01x3x1.00.40.96.60.91.311.0244RE-2Y(St)HSWAH 1T1.31x3x1.30.450.97.20.91.311.6268RE-2Y(St)HSWAH 1T1.51x3x1.50.450.97.50.91.311.9277Note : Other conductor sizes & core configurations are available upon requestElectrical PROPERTIESConductor Area Sizemm 20.50.751.01.31.5Insulation thickness (nominal)mm0.350.380.40.450.45Conductor resistance (20°C)Ω/km36.72518.514.212.3Insulation resistance (20°C)MΩ.km(Min.)5000Mutual Capacitance (1 kHz)pF/m(Max.)115Capacitance unbalance(1 kHz)pF/500 m (Max.)500L / R (ratio) (max.)μH/Ω2525254040InductancemH/km(Max.)11111Operating voltage UrmsV300Test VoltageCore to CoreV1500Core to ScreenV1500


在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

NTSWOEU 0.6/1kV E-Loader Cable VDE 0250 Part 813ApplicationsThese cables are used for the connection of mobile machines under extremelyhigh mechani...
450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (2-4 Cores) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainl...
2YSLGCGOEU Signal & Control Cable VDE 0250 Part 812ApplicationsThese control,Website:, signalling and bus cables are used for electric and electron...
UL Industrial Cables USE-2Application and DescriptionThe product can be installed as general purpose building wire,Website:, used in service entran...
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8115ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes