H05V2V2-F/H05V2V2H2-F

VDE Industrial Cables H05V2V2-F/H05V2V2H2-F Application and DescriptionThese cables are suitable for domestic premises,Website:, kitchen, office for light service or light portable apparatuses. With their special insulation and sheatd compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperature (like lighting system apparatuses) without contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high temperature use, skin contact must be avoidedStandard and ApprovalHD 21.12; HD 308 S2, DIN VDE 0281 part 1, part 12, DIN VDE 0293 part 308, DIN VDE 0295CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), CENELEC HD 21.12 S1 /EN50265-2-1Cable Construction- Bare copper fine wire conductor- Stranded to DIN VDE 0295 cl. 5, IEC 60228 cl. 5 and HD 383- PVC core insulation T13 to VDE-0281 Part 1- Green-yellow grounding (3 conductors and above)- Color coded to VDE-0293-308- PVC outer jacket TM3Technical Characteristics- Working voltage: 300/500 volts- Test voltage: 2000 volts- Flexing bending radius: 15 x Ø- Static bending radius: 4 x Ø- Flexing temperature: +5º C to +90º C- Static temperature: -40º C to +90º C- Short circuit temperature: +160º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM²NOMINAL THICKNESS OF INSULATIONMMNOMINAL THICKNESS OF SHEATHMMNOMINAL OVERALL DIAMETERMMNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KMH05V2V2-F18(24/32)2 x 0.750.60.86.214.454.218(24/32)3 x 0.750.60.86.621.66518(24/32)4 x 0.750.60.87.12977.718(24/32)5 x 0.750.60.983697.317(32/32)2 x 1.000.60.86.41960.517(32/32)3 x 1.000.60.86.82973.117(32/32)4 x 1.000.60.97.6389317(32/32)5 x 1.000.60.98.348111.716(30/30)2 x 1.500.70.87.42982.316(30/30)3 x 1.500.70.98.143104.416(30/30)4 x 1.500.71.0958131.716(30/30)5 x 1.500.71.11072163.114(30/50)2 x 2.500.81.09.248129.114(30/50)3 x 2.500.81./50)4 x 2.500.81.110.996199.614(30/50)5 x 2.500.81.212.4120245.412(56/28)3 x 4.000.81.211./28)4 x 4.000.81.212./28)5 x 4.000.81.413./28)3 x 6.000.81.113./28)4 x 6.000.81.313.9230490H05V2V2H2-F18(24/32)2 x 0.750.60.84.2 x 6.814.14817(32/32)2 x 1.000.60.84.4 x 7.21957
Other supplier products
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (2-4 Cores) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainl... |
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 15kV ICEA S-75-381ApplicationsThese cables are designed for connections be... |
|
|
|
300/500V XLPE Insulated,Website:, PVC Sheathed Power Cables (Single Core)Application:The cables are mainly used in power stations, mass transit und... |
|
|
|
VDE Standard Industrial Cables H03VV-F/H03VVH2-F pplication and DescriptionThese cable types are especially suited for use on small appliances with... |
|
|
|
P1 or P1/P8 RFOU/TFOU 0.6/1KV NEK606 Power cableApplications :Marine cables are flame retardant,Website:, low smoke, halogen free and mud resistant... |