THHN/THWN, 600V, Type TC Control Cable

UL Industrial Cables THHN/THWN,Website:, 600V, Type TC control Cable Application and DescriptionType TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired. Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire. Type TC is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Conductors may be used at temperatures not to exceed 75°C in wet locations or 90°C in dry locations. 130°C for emergency overload ratings, and 250°C for short circuit ratings. Not recommended in D.C. operation in wet locations.Cable ConstructionConductorSoft annealed bare copper, Class B stranding per ASTM B8InsulationPolyvinyl chloride (PVC) insulation over witd a nylon (polyamide) jacket appliedAssemblyThree or more conductors will be cabled round witd fillers and a nylon rip cord is put under tde jacket for ease of strippingJacketHeat retardant, moisture and sunlight resistant PVCColorupon request, black is preferableTechnical Compliances- NFPA 70 (NEC)- UL 1581 - Electrical Wires, Cables and Flexible Cords- ICEA S-58-679 - Control Cable Conductor Identification Metdod 1, Table 2- UL 1685 - UL Flame Exposure Test (70,000 Btu/hr)Cable ParameterInsulation tdickness: 16-12AWG PVC 15mils(0.38mm) Nylon 4mils(0.10mm)10AWG PVC 20mils(0.50mm) Nylon 4mils(0.10mm)AWG 16 (26 STRANDS) - TYPE TC-TFFN* CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.2887.32436430.0451.140.3037.70537940.0451.140.3298.36669850.0451.140.3579.078112070.0451.140.3869.8010315390.0451.140.44711..0451.140.50112..0601.520.58514..0601.520.61415..0601.520.71318..0802.030.75319..0802.030.81220.62477709AWG 14 (7 strands) - Type TC-THHN or THWN ConductorsNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.3057.8568330.0451.140.3228.27411040.0451.140.3508.99313950.0451.140.3819.710916260.0451.140.41310.512919270.0451.140.41310.514521580.0451.140.44611.316424390.0451.140.47812.2182271100.0601.520.55014.0217322120.0601.520.56814.4251373150.0601.520.62715.9305454190.0601.520.65816.7373555200.0601.520.69117.6393584250.0601.520.76619.4483719300.0601.520.81020.6568845370.0802.030.91323.27201072AWG 12 (7 STRANDS) - TYPE TC-THHN OR THWN CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.3408.67511230.0451.140.3609.210515640.0451.140.39210.012819050.0451.140.42810.915422960.0451.140.46611.818327270.0451.140.46611.820730880.0451.140.50412.823434990.0601.520.57214.5277412100.0601.520.62115.8307457120.0601.520.64116.3358532150.0601.520.71018.0438652190.0601.520.74618.9539802200.0601.520.78519.9568845250.0802.030.91123..0802.030.96324..0802.031.03626.310441553AWG 10 (7 STRANDS) TYPE TC-THHN OR THWN CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.40710.311116630.0451.140.43311.015523040.0451.140.47312.019829450.0601.520.54913.925037160.0601.520.59615.129443770.0601.520.59615.133349580.0601.520.64516.437756190.0601.520.69317.6421626100.0601.520.75519.2467694120.0601.520.78019.8547814150.0802.030.90823..0802.030.95424..0802.031.00325..0802.031.11228..0802.031.17729..0802.031.27132.316142402
Other supplier products
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 8774,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8335ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
Multipair Individually and Overall Screened Cables-Belden Equivalent 8170ApplicationsThese cables have individually screened pairs laid up in a foi... |
|
|
|
300/500V Mica+XLPE Insulated,Website:, LSZH Sheathed fire resistant Power Cables (2-4cores)(CU/MGT+XLPE/LSZH 300/500V Class 2)Application:The cable... |
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Jacket, 25kV to ICEA S-75-381ApplicationsThese cables are designed for connections... |
供应产品
Same products