Mud Resistant Cat 5e S/FTP 0.22mm²
Mud Resistant Cat 5e S/FTP 0.22mm2 IEC60092ApplicationThese Cat5e S/FTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can support all Class D applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for basic voice and data installations up to 100MHz. These cables have additional flame retardant, halogen-free, low smoke MUD protecting outer sheaths.StandardsEN 50173-1EN 50288-2-1ISO/IEC 11801IEC 61156-5IEC 60332-3-24IEC 60754-1/2IEC 61034-1/2ConstructionConductorsStranded copper conductor.InsulationPE.TwinningTwo coloured insulated conductors twisted together to form a pair.Individual ScreenAl/polyester tape.Overall ScreenTinned copper wire braid.Inner SheathOil resistant, flame retardant and halogen free LSOH (SHF1).Outer SheathMUD protecting.Core IdentificationPair 1: White, Blue
Pair 2: White, Orange
Pair 3: White, Green
Pair 4: White, BrownElectrical PropertiesMaximum DC Loop ResistanceΩ/km158Maximum Resistance Unbalance2%Minimum Insulation Resistance (500V)MΩ.km5000Nominal Capacitance @800HznF/km43Maximum Capacitance Unbalance (pair to ground)pF/km1500Mean Characteristic Impedance @100MHzΩ100 ± 5Nominal Velocity of Propagation0.75cMaximum Propagation Delayns/100 m450Maximum Delay Skewns/100 m15Maximum Transfer Impedance @1MHzmΩ /m10Maximum Transfer Impedance @10MHzmΩ /m8Maximum Transfer Impedance @30MHzmΩ /m10Minimum Coupling AttenuationdB85Nominal Transmission Characteristics @20℃FAttenuationNEXTACRReturn LossPS-NEXTPS-ACRELFEXTPS-ELFEXTMHzdB/100mdBdB/100mdBdBdB/100mdB/100mdB/100m12......2511..516...024..031...047..060.Mechanical and Thermal PropertiesBending Radius: 8×OD (during installation); 4×OD (fixed installed)Temperature Range: -40℃ ~ +85℃Dimensions and WeightPart No.ConstructionNo. of elements×No. of cores in element×Crosssection(mm²)Nominal Insulation ThicknessmmNominal Sheath Thickness mmNominal Overall DiametermmNominal Weight kg/kmInnerOuterUE092-S/FTPCAT5EM4P22S4×2×0.220.40.750.99.5100
Other supplier products
|
|
250V [FA-] TTY-S,Website:, TTYC-S, TTYCY-S [FA-] TTPY-S, TTPYC-S, TTPYCY-SStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CO... |
|
|
UL Industrial Cables XHHW/PVC Jacket,Website:, Power Cable, CT RatedApplication and DescriptionXHHW/PVC conductors are primarily used in conduit, c... |
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8342ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
300/500V Mica+XLPE or SR Insulated & Overall screened Multicore fire resistant Instrumentation cablesRE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OS/... |
|
|
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control CablesApplication:Th... |
供应产品
Same products