Drive-in Solar Simulation Automotive Test Chamber

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

Full Vehicle Sunlight Simulation Test Chamber is designed to evaluate the aging performance of complete assemblies or entire vehicles under sunlight exposure. Users can assess changes in performance after irradiation, including alterations in shape, color, gloss, texture, strength, and various thermal expansion results. Additionally, it tests key metrics such as vehicle starting capability, motor performance, and overall air conditioning functionality under solar radiation.

Standards

GB/T 12535-2007 Test Methods for Starting Performance of Automobiles

GB 11556-2009 Defrosting and Demisting Test

GB/T 18297-2001 (Reference) Motor Performance Test

GB/T 2423.24-1995 Solar Radiation Test

GB/T 2423.3-2006 Test Method for Constant Humidity and Heat

GB/T 12782-2007 Requirements and Test Methods for Automotive Heating Performance

QC/T 658-2000 Test Method for Automotive Air Conditioning System Performance

Parameters

CategorySpecifications
Temperature Control Range -20°C ~ +60°C
Humidity Range Relative humidity: 30% ~ 95%, no condensation in the low-temperature test chamber• Without illumination: 30% ~ 95% RH• With illumination: 30% ~ 80% RH
Condition Control a. Cooling Time• 25°C ~ -20°C: ≤ 85 min (no load)• 60°C ~ 25°C: ≤ 40 min (no load)b. Heating Time• -20°C ~ 25°C: ≤ 50 min (no load)• 25°C ~ 60°C: ≤ 50 min (no load)c. Temperature Fluctuation• ≤ ±0.5°C (no load)d. Temperature Uniformity• ≤ ±1.5°C (no load)e. Temperature Deviation• ≤ ±2.0°C (with load, measured at vehicle front air inlet, roof, left and right sides)
Illumination System a. Infrared Radiation Lamps• Working ambient temperature: -20°C ~ 60°C• Maximum radiation intensity: 1200±25W/m², uniformity: ±10%• Adjustment range: 30% ~ 100%b. Simulated Lamps• Uses two-terminal linear medium-wave infrared simulation lamps• Service life: ≥ 5000h (radiation intensity remains stable during this period)c. Illumination Adjustment• Automatically and manually adjustable via temperature control on the vehicle surfaced. Projection Area & Movement• Projection area: 5000mm × 2500mm (L×W)• Vertical movement distance: Minimum 2200mm, maximum 3000mm (distance from the lower surface of the lamp to the chamber bottom)

Accessories

1.Solar Simulation Array: Vertically adjustable lamp rack with medium-wave IR lamps.

2.Humidity Control System: Includes a high-pressure water spray and dehumidification unit.

3.Sensor Package: High-precision temperature and humidity sensors, plus pyranometers for radiation monitoring.

4.Vehicle Interface Port: Sealed pass-throughs for vehicle exhaust and data cables.

5.Safety System: Over-temperature protection, emergency stop, and smoke detection alarms.

Test Procedures

1. Equipment and Sample Preparation

Equipment Inspection: Verify that the solar simulator chamber's irradiance (1000 W/m²), temperature (-40°C to 110°C), humidity (5%–95% RH), and air velocity (0.5–10 m/s) parameters comply with standards.

Sample Installation: Position the test vehicle at the chamber center, ≥0.3m from chamber walls, with ≥0.76m distance from radiation lamps.

2. Test Implementation

Cycle Test:

Cycle Count: Minimum 3 cycles, maximum 7 cycles, each lasting 24 hours.

Irradiance Control: Adjust in segments or continuously to maintain constant total energy.

Temperature Regulation: Set ambient and radiation temperatures according to test requirements.

Humidity Regulation: Control surface humidity via a water spray system.

Steady-State Test:

Cycle Count: Determined by exposure duration (e.g., 4 cycles for a 10-day test).

Parameter Settings: Maintain stable irradiance, temperature, and humidity.

3. Performance Testing

Initial Inspection: Record specimen appearance, temperature sensor data, and operational performance before testing.

Intermediate Inspection: Conduct visual inspection, dimensional measurement, and electrical testing at peak temperature.

Final Inspection: Evaluate performance changes post-testing to ensure compliance with product specifications.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Tensile and Shear Tester STD - FB1 - A
Tensile and Shear Tester STD - FB1 - A The Tensile and Shear Tester analyzes hand movements-referred to as "tensile"and "shear"-performed by artisans and professionals when judging a fab...
 Intervertebral Fusion Cages Torsion Fatigue Tester
Intervertebral Fusion Cages Torsion Fatigue Tester Standard YY/T 0959-2014 (China): Specifies torsional fatigue testing protocols for intervertebral fusion devices, including load ratios, frequency...
Full Vehicle Sunlight Simulation Test Chamber,Full Vehicle solar simulation Corrosion test chamber
Full Vehicle Sunlight Simulation Test Chamber,Full Vehicle solar simulation Corrosion test chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com The Full Vehicle Sunlight Simulation Test Chamber is a high-precision environmental testing...
Femoral Condyles Components Fatigue Performance Tester
Femoral Condyles Components Fatigue Performance Tester Standard ASTM WK51649: Specifies fatigue testing protocols for metallic femoral components in total knee arthroplasty, including F-N curve generat...
Humidity Chamber
Humidity Chamber Features and Benefits 1. The humidity test chamber can realize long-term 85°C 85%RH test. The automatic water inlet and water circulation syst...
供应产品

Same products

Walk-in Environmental Constant Temperature and Humidity Test Chamber
Walk-in Environmental Constant Temperature and Humidity Test Chamber 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2423.3 Environmental Testi...
High reliability walk-in heat aging chamber
High reliability walk-in heat aging chamber 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Walk-in High-Temperature Ag...
Fully programmable walk-in climate simulation system
Fully programmable walk-in climate simulation system 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications High and Low Temperature Hu...
PV Degradation Testing Chamber
PV Degradation Testing Chamber 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Light Decay Test Chambe...
PV module acid corrosion test equipment supplier
PV module acid corrosion test equipment supplier 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Photovoltaic Acid Mist ...