Computer-controlled Explosion-proof Capillary Rheometer, ISO 11443 automated explosion-proof capillary rheometer
The Computer-controlled Explosion-proof Capillary Rheometer is a laboratory rheological testing instrument used to determine the melt flow behavior and apparent viscosity of plastics and polymer materials under controlled temperature, pressure, and shear conditions. The system integrates servo-driven loading, precision capillary dies, uniform heating, and computer-based measurement and control, enabling stable, repeatable, and standard-compliant rheological characterization for thermoplastics and thermosetting materials.
Application
(1) Measurement of apparent viscosity and shear rate characteristics of thermoplastic materials under specified temperature and shear stress conditions.
(2) Rheological characterization of thermosetting polymer melts during controlled extrusion through capillary dies.
(3) Evaluation of melt flow behavior under constant pressure, constant speed, constant temperature, or variable heating rate conditions.
(4) Comparative analysis of polymer processing performance for extrusion, injection molding, and compounding processes.
(5) Research and development of new polymer formulations, additives, and modified materials.
(6) Quality control and batch consistency verification in polymer manufacturing.
(7) Rheological testing for academic research, industrial laboratories, and material certification institutions.
Standards
(1) HG/T 4300-2012 — Capillary Rheometer Test Method for Plastics
(2) ISO 11443 — Plastics — Determination of the Fluidity of Plastics Using Capillary and Slit-Die Rheometers
(3) ASTM D3835 — Standard Test Method for Determination of Rheological Properties of Thermoplastics Using a Capillary Rheometer
(4) DIN 54811 — Plastics — Determination of Flow Behavior Using Capillary Rheometers
(5) GB/T 21060 — Plastics — Determination of Melt Rheological Properties (Capillary Method)
Features
(1) Computer-controlled measurement and control system enabling automatic test parameter configuration and data acquisition.
(2) Single-column, single-indenter structure with explosion-proof design for safe operation.
(3) AC servo drive combined with precision ball screw transmission for accurate displacement and pressure control.
(4) Uniform barrel heating using integrated spiral heating wire to ensure temperature stability along the flow path.
(5) Supports constant pressure, constant speed, constant temperature, and variable heating rate test modes.
(6) Automatic generation of rheological curves with real-time display, storage, and printing functions.
(7) Modular and customizable design for temperature range, pressure capacity, indenter diameter, and die specifications.
(8) Intuitive software interface for parameter setting, test execution, and result analysis.
Parameters
| Item | Specification |
|---|---|
| Temperature range | Room temperature to 400 ℃ |
| Heating rate | 1–10 ℃/min, continuously adjustable |
| Temperature resolution | 0.1 ℃ |
| Pressure range | 1–50 MPa |
| Pressure accuracy | ±0.5 % FS |
| Pressure resolution | 0.1 MPa |
| Maximum driving force | 10 kN |
| Speed range | 0.01–500 mm/min |
| Deformation measurement accuracy | ±0.5 % FS |
| Standard plug head diameter | Φ12 mm |
| Plug head area | 113.04 mm² |
| Capillary die specifications | Ø1 × 5 mm, Ø1 × 10 mm, Ø1 × 20 mm, Ø1 × 40 mm |
| Capillary die material | Tungsten carbide |
| Power supply | AC 220 V, 50 Hz |
| Rated power | < 1000 W |
Accessories
(1) Standard tungsten carbide capillary die set
(2) Standard Φ12 mm plug head
(3) Temperature sensor and pressure sensor assembly
(4) Computer control and analysis software
(5) Data cable and power cable
(6) Operation manual and calibration documentation
Test Procedures
(1) Install the selected capillary die and plug head according to the test requirement.
(2) Power on the system and set the target temperature and heating rate.
(3) Load the polymer sample into the barrel and allow it to reach thermal equilibrium.
(4) Configure test mode (constant pressure, constant speed, or programmed shear rate).
(5) Start the test and monitor pressure, displacement, and temperature in real time.
(6) Allow the software to automatically record data and generate rheological curves.
(7) Save, print, or export test results after completion.
Maintenance Information
(1) Clean the barrel, plug head, and capillary dies immediately after testing to prevent material residue solidification.
(2) Regularly inspect heating elements and temperature sensors for accuracy and stability.
(3) Calibrate pressure and displacement sensors periodically according to laboratory requirements.
(4) Lubricate mechanical transmission components as specified in the maintenance manual.
(5) Keep the control system and software updated to ensure stable operation and data integrity.
(6) Store capillary dies and precision components in a clean, dry environment to prevent damage.
在线联系供应商
Other supplier products
| Freeze Resistance Test Chamber | Features and Benefits 1. Mechanical refrigeration unit, adopts cascade refrigeration mode, high refrigeration efficiency and stable refrigeration.... | |
| Helmets Vertical SpacingInfrared - positioning Tester | The helmet vertical spacing infrared positioning tester is a specialized instrument used to measure the vertical spacing and wearing height of safe... | |
| Falling Sand Abrasion Tester | Applicable Standard JG/T 133-2000 ASTM D968-83 ASTMD333 ASTMD1395 ASTMD2205 Main Purposes It is mainly used to test the abrasion - resistanc... | |
| Drapery Flammability Tester | I. Product Overview TheDrapery Flammability Testeris a specialized instrument designed to evaluate the flame resistance of textiles and drapery ma... | |
| Computer-controlled Explosion-proof Capillary Rheometer, ISO 11443 automated explosion-proof capillary rheometer | The Computer-controlled Explosion-proof Capillary Rheometer is a laboratory rheological testing instrument used to determine the melt flow behavior... |