Precision thermal conductivity tester for R&D and quality control
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
TheHigh-Precision Material Thermal Conductivity Tester is suitable for steady-state thermal performance evaluation of materials with low to medium thermal conductivity, including:
Thermal insulation materials
Plastics and polymer-based materials
Rubber and elastomer materials
Aerogel panels and advanced insulation boards
Vacuum glass and building energy-saving materials
Solid materials and powder materials (with appropriate sample configuration)
The instrument is widely used in universities, research institutes, quality inspection laboratories, and industrial material testing facilities for thermal conductivity and thermal resistance analysis.
Standards
The instrument is designed and operated in accordance with the following international and national standards:
GB/T 10295-2008
Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter method
ASTM E1530
Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique
ASTM C518-04
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
Parameters
| Item | Specification |
|---|---|
| Thermal conductivity range (low range) | 0.0001 – 1 W/m·K (resolution up to 0.1 mW/m·K) |
| Thermal conductivity range (extended) | 0.001 – 300 W/m·K |
| Measurement accuracy | ±1% |
| Sample size | 50 × 50 to 300 × 300 mm |
| Maximum sample thickness | ≤ 50 mm |
| Optional sample sizes | 600 × 600 mm, 800 × 600 mm (customized) |
| Applicable sample form | Solid materials, powder materials |
| Test duration | 15 – 20 min |
| Hot plate temperature range | Room temperature to 99.9 °C (standard) |
| Optional hot plate range | Room temperature to 499.9 °C or higher (by agreement) |
| Hot plate control accuracy | 0.1 °C |
| Cold plate temperature range | 0 – 99.9 °C (standard); –10 – 99.9 °C optional |
| Cold plate temperature control | Water-cooled, precision constant-temperature bath |
| Cold plate control accuracy | 0.1 °C |
| Pressure range | 0 – 1000 N |
| Pressure resolution | 0.1 N |
| Thickness measurement range | 0 – 50 mm |
| Thickness resolution | 0.1 μm |
| Heat flow sensor | Imported original heat flow meter |
| Test operation | Fully automatic computer-controlled testing and data storage |
| Power supply | AC 220 V / 50 Hz |
Test Procedures
Prepare the specimen according to size and thickness requirements.
Place the specimen between the hot plate and cold plate.
Set the target hot-side and cold-side temperatures in the software.
Apply pressure automatically to ensure stable contact.
Allow the system to reach steady-state heat transfer conditions.
Measure the heat flux and temperature gradient across the specimen.
Calculate thermal conductivity and thermal resistance automatically.
Save and print test data and reports.
Maintenance Information
Keep hot and cold plate surfaces clean and undamaged
Ensure proper operation of the constant-temperature water bath
Periodically check sensor performance and calibration status
Maintain stable laboratory environmental conditions during testing
Store reference samples and accessories properly when not in use
在线联系供应商
Other supplier products
| Aluminum Ointment Tube Toughness Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The ductility tester for aluminum tubes is a device specifically used to detect the ductili... | |
| Continuous Flow Reaction Calorimeter ASTM Standards | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)SN/T 3078.1:Inspection of Imported and Exported Commodities - S... | |
| ASTM E662 smoke density tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument conforms to the following national and international standards: ... | |
| Fire Testing Equipment for Flammability | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The equipment meets the following standards: ISO 12136 – Determination of... | |
| Automotive Wire Repeated Bending Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automotive Wire Repeated Bending Tester is designed to evaluate the durability of autom... |
Same products
| HDPE高速水冷双壁波纹管生产线 | 卖方: Shandong HUASU Plastic Technology Co.,Ltd. | 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功... | |
| PanEVAP & MVR system | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... |