Precision thermal conductivity tester for R&D and quality control

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Application

TheHigh-Precision Material Thermal Conductivity Tester is suitable for steady-state thermal performance evaluation of materials with low to medium thermal conductivity, including:

Thermal insulation materials

Plastics and polymer-based materials

Rubber and elastomer materials

Aerogel panels and advanced insulation boards

Vacuum glass and building energy-saving materials

Solid materials and powder materials (with appropriate sample configuration)

The instrument is widely used in universities, research institutes, quality inspection laboratories, and industrial material testing facilities for thermal conductivity and thermal resistance analysis.

Standards

The instrument is designed and operated in accordance with the following international and national standards:

GB/T 10295-2008

Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter method

ASTM E1530

Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique

ASTM C518-04

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Parameters

ItemSpecification
Thermal conductivity range (low range) 0.0001 – 1 W/m·K (resolution up to 0.1 mW/m·K)
Thermal conductivity range (extended) 0.001 – 300 W/m·K
Measurement accuracy ±1%
Sample size 50 × 50 to 300 × 300 mm
Maximum sample thickness ≤ 50 mm
Optional sample sizes 600 × 600 mm, 800 × 600 mm (customized)
Applicable sample form Solid materials, powder materials
Test duration 15 – 20 min
Hot plate temperature range Room temperature to 99.9 °C (standard)
Optional hot plate range Room temperature to 499.9 °C or higher (by agreement)
Hot plate control accuracy 0.1 °C
Cold plate temperature range 0 – 99.9 °C (standard); –10 – 99.9 °C optional
Cold plate temperature control Water-cooled, precision constant-temperature bath
Cold plate control accuracy 0.1 °C
Pressure range 0 – 1000 N
Pressure resolution 0.1 N
Thickness measurement range 0 – 50 mm
Thickness resolution 0.1 μm
Heat flow sensor Imported original heat flow meter
Test operation Fully automatic computer-controlled testing and data storage
Power supply AC 220 V / 50 Hz

Test Procedures

Prepare the specimen according to size and thickness requirements.

Place the specimen between the hot plate and cold plate.

Set the target hot-side and cold-side temperatures in the software.

Apply pressure automatically to ensure stable contact.

Allow the system to reach steady-state heat transfer conditions.

Measure the heat flux and temperature gradient across the specimen.

Calculate thermal conductivity and thermal resistance automatically.

Save and print test data and reports.

Maintenance Information

Keep hot and cold plate surfaces clean and undamaged

Ensure proper operation of the constant-temperature water bath

Periodically check sensor performance and calibration status

Maintain stable laboratory environmental conditions during testing

Store reference samples and accessories properly when not in use


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

KES - G5 Compression Tester
KES - G5 Compression Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Compression Tester analyzes hand movements-particularly, movements by finger-performed ...
Film Heat Shrinkage Tester
Film Heat Shrinkage Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The film heat shrinkage rate tester is a device specifically designed to measure the shrink...
Luggage lifting and unloading testing machine
Luggage lifting and unloading testing machine Whats/App: +86 156 1874 6768 Web: standard-groups.com The luggage simulation lifting and unloading tester is a measuring instrument for the life ...
Coatings Shear
Coatings Shear Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0856-2011 (China): Specifies mechanical testing protocols for metal angular ...
NES 713 High-Precision Smoke Toxicity Test Chamber
NES 713 High-Precision Smoke Toxicity Test Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The equipment is designed and manufactured in compliance with the following stan...
All supplier products

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Seller: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...