Blood collection tube vacuum tester machine

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The design and manufacture of the Vacuum Blood Collection Tube Aspiration Volume Tester must comply with relevant medical industry standards, such as YY 0314 - 2021Disposable Human Venous Blood Sampling Containers. This standard clearly specifies key indicators, including the error range of the aspiration volume of blood collection tubes, container leakage tests, and container strength tests, to ensure the usability and safety of blood collection tubes. The tester must strictly adhere to these standards during the design and manufacturing process to ensure the accuracy and reliability of test results.

Features

1.Adoption of PLC Industrial Control System: The PLC industrial control system offers high stability and reliability, ensuring precise control of the testing process. It can quickly respond to various commands, enabling accurate adjustment of parameters such as test pressure and time, guaranteeing high accuracy and repeatability of test results. For example, when performing multiple blood collection tube aspiration volume tests, the PLC control system ensures consistent test conditions each time, improving testing efficiency and accuracy.

2. 7-inch HMI Touchscreen:Operation is simpler and more intuitive. Test personnel can easily set test parameters and view test results via the touchscreen, eliminating complex operating procedures. Even first-time users can quickly master the operation method, improving work efficiency.

3. Extra-thick Acrylic Vacuum Chamber: Provides excellent sealing and visibility. The sealing ensures the stability of the pressure environment during testing, preventing external air interference with test results; the visibility allows test personnel to observe the puncture and blood collection process of the blood collection tube, enabling timely detection and resolution of problems.

4. Built-in Vacuum Device:Eliminates the need for an external air source, reducing the complexity and cost of equipment use. Users only need to connect the power supply to quickly start testing, making it convenient and suitable for testing needs in various locations.

Technical Parameters

Serial No.Parameter ItemParameter Details
1 Vacuum Degree Test range: 0 - 90kPa (meets testing requirements of different altitude areas)
2 Vacuum Degree Accuracy 0.5- level (ensures measurement precision)
3 Vacuum Degree Maintenance Performance Equipped with automatic air-supplement and constant-pressure maintenance functions (ensures vacuum degree stability during testing)
4 Operation Control Mode Fully automatic control + touch-screen operation (simplifies testing process and improves efficiency)
5 Air Source Pressure Requirement 0.7 - 0.9MPa (air source to be provided by user; ensures normal operation of the tester)
6 Air Source Generator Uses imported components (e.g., Japanese SMC generators) with a stability of ±0.1kPa (improves testing accuracy)
7 Power Supply Supports multiple specifications (e.g., AC 220V 50Hz/120V 60Hz) (adapts to different regional power environments)
8 External Dimensions Main unit size: 300mm(L)×385mm(W)×150mm(H) (specific size may vary by model; easy to place and operate)
9 Weight Net weight of main unit: approximately 7kg (actual weight may vary by configuration; facilitates portability and movement)
10 Language Supports Chinese/English (standard configuration); other languages (e.g., Russian, Traditional Chinese) available for customization (meets different users' needs)

Accessoriess

1. Main Unit: The RDVT-01 testing instrument main unit integrates the PLC control system, human-machine interface touchscreen, vacuum chamber, and other core components, making it the core of the entire testing system.

2. Puncture Needle: Made of high-quality materials to ensure smooth and accurate puncture, avoiding damage to the blood collection tube.

3. High-Precision Weighing Sensor: Used to accurately measure the weight difference of the blood collection tube before and after testing, ensuring the accuracy of the test results.

4. Connecting Tubing: Features good sealing and corrosion resistance, ensuring stable and reliable pressure transmission.

5. Operation Manual: Provides detailed instructions on the operation methods and maintenance precautions of the testing instrument, helping users to correctly use and maintain the equipment.

Test Procedures

1. Sample Preparation

Randomly select 30 blood collection tubes and equilibrate them for 1 hour at 20℃±2℃.

Use standard Grade 3 water as the medium to avoid temperature fluctuations affecting density.

2. Equipment Calibration

Connect the pre-vacuum blood collection tube aspiration volume tester and vacuum pump, and remove air bubbles from the tubing.

Calibrate the vacuum level to the target value (e.g., -30 kPa for simulating an altitude of 3000 meters).

3. Test Execution

Insert the blood collection tube into the puncture site of the testing system, start the vacuum pump, and maintain stable pressure for 1 minute.

Record the weight difference of the blood collection tube before and after water aspiration, and calculate the individual and batch average aspiration volume.

4. Result Judgment

If the batch average aspiration volume is within ±10% of the nominal value, it is judged as qualified.

Generate a test report, including the pressure-time curve, weight data, and deviation analysis.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Minimum Ignition Temperature (MIT) – Dust Cloud Tester
Minimum Ignition Temperature (MIT) – Dust Cloud Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Dust Cloud Minimum Ignition Temperature Tester is mainly used to assess the explosiveness o...
FPC Flex Durability Tester
FPC Flex Durability Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM F392 Product features 1. the stepper motor drive, high-precision positioni...
Protective Clothing Thermal Conductivity Tester
Protective Clothing Thermal Conductivity Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable Standards: ISO 11092:2014 ASTM D1518-17 ASTM F1868 ISO 5085-1 ISO 9920 The pr...
Touch Haptics Test System,Automotive interior material tactile perception quality testing program system
Touch Haptics Test System,Automotive interior material tactile perception quality testing program system Whats/App: +86 156 1874 6768 Web: standard-groups.com The Touch Haptics Test System is a precision laboratory instrument designed to evaluate the...
Automatic catheter vacuum leak apparatus
Automatic catheter vacuum leak apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB 15812.1 - 2005 :Non - Vascular Intravascular Catheters - Part 1: General Perf...
供应产品

Same products

Mini Jewelry Laser Welding Machine
Mini Jewelry Laser Welding Machine 卖方: Beijing JCZ Technology Co., Ltd The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre...
Pulse Laser Cleaner | Handheld Solution for Precision Surface Cleaning for Rust & Coating
Pulse Laser Cleaner | Handheld Solution for Precision Surface Cleaning for Rust & Coating 卖方: Beijing JCZ Technology Co., Ltd Looking for an efficient and eco-friendly laser cleaning machine? The HCP Series Pulse Laser Clea...
Mini Type Laser Marking & Engraving Machine – Fiber & UV Laser Options for Precise Marking
Mini Type Laser Marking & Engraving Machine – Fiber & UV Laser Options for Precise Marking 卖方: Beijing JCZ Technology Co., Ltd This compact, Mini Type fiber laser marking machineis perfectly suited for small businesses, work...
Large Enclosed Laser Marking & Engraving Machine for Industrial Use
Large Enclosed Laser Marking & Engraving Machine for Industrial Use 卖方: Beijing JCZ Technology Co., Ltd The Large Closed Laser Marking Machineis a high-performance engraving solution designed for indus...
Axial force wire guide apparatus
Axial force wire guide apparatus 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YYT0807 - 2010 :Standard Guide...