Buy Medical glove water-impermeability tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
- GB 10213 - 2006 Impermeability Test in Appendix A of Medical Rubber Examination Gloves
- GB 7543 - 2006 Impermeability Test in Appendix A of Sterile Rubber Surgical Gloves
- ASTM D5151 Standard Test Method for Detection of Holes in Medical Gloves, etc.
Features
1. Independently designed and original, with a beautiful and elegant appearance.
2. The bucket is made of high-grade acrylic, which will never yellow.
3. Aluminum alloy frame and stainless steel fittings ensure sturdiness, durability, and resistance to deformation.
4. Equipped with lockable swivel casters for easy movement.
Technical Parameters
| Serial No. | Parameter Item | Parameter Details |
|---|---|---|
| 1 | Capacity | At least 1000mL; ensures water filling and keeps gloves in a vertical state during testing |
| 2 | Number of Stations | Equipped with multiple stations (e.g., 12 stations) to improve testing efficiency; each station has an automatic clamping function to ensure gloves' stability and accuracy during testing |
| 3 | Liquid-adding Function | Equipped with automatic liquid-adding function; liquid-adding time can be set, which simplifies the testing process and improves testing accuracy |
| 4 | Timing Function | Equipped with an independent timer to record test time; ensures the accuracy and repeatability of test results |
| 5 | Operation Interface | Equipped with a large-screen touch screen; supports operation mode with Chinese and English menus, facilitating user operation |
| 6 | Transparent Cylindrical Tube | Outer diameter: 60mm; inner diameter: 50mm; capacity: 1000mL of water; used to place gloves for testing |
Accessoriess
1. Suspension device: The gloves are secured through a suspension system to prevent displacement during testing, thus avoiding deviations in the results.
2. Special sample clamp: Ensures a tight seal between the glove and the testing system, preventing liquid leakage that could affect the test results.
3. Pressure monitoring: Some models are equipped with a precision pressure gauge that displays the air pressure value in real time, with an accuracy of ±1kPa, ensuring testing stability.
Test Procedures
1. Preparation Before Operation
Equipment and Accessory Check:
Confirm that the instrument's transparent cylindrical tube (outer diameter 60mm, inner diameter 50mm, capacity 1000mL), multi-station (e.g., 12-station) automatic clamping function, automatic liquid filling, and timing module are functioning correctly; check that the equipment power supply and operating interface (Chinese and English touch screen) are stable.
Sample Preparation:
Select the medical gloves to be tested (e.g., rubber examination gloves, sterile surgical gloves), ensuring that the gloves are free of damage and stains, and conform to the product type corresponding to the test standard.
Standard Matching:
Clearly identify the standard to be followed for the test, and confirm the corresponding test duration requirements.
2. Equipment Parameter Settings
Start the instrument and select the matching test standard via the Chinese and English touch screen;
Set core parameters:
Liquid Filling Time: Set the automatic liquid filling duration according to the transparent cylindrical tube capacity (1000mL);
Test Time: Set the independent timer according to the duration required by the corresponding standard ;
Station Selection: Enable the required number of stations to improve testing efficiency.
3. Sample Installation
Place each medical glove onto the transparent cylindrical tube port of each station;
Activate the automatic clamping function of each station to fix the gloves and ensure they are in a vertical position, avoiding wrinkles or looseness (to prevent leakage during the test that is not due to the glove itself).
4. Automatic Liquid Filling and Test Start
Activate the automatic liquid filling function to fill each transparent cylindrical tube with water to 1000mL, ensuring the gloves are completely covered with water;
After confirming that the liquid filling is complete and there is no initial leakage, start the timer to begin the water tightness test.
5. Test Process Monitoring
During the test, observe the status of the gloves at each station: whether there is water leakage or penetration marks;
Maintain a stable testing environment (e.g., room temperature 20±5℃), avoiding external forces interfering with the equipment or gloves.
6. Test Completion and Result Determination
After the test duration is complete, stop the timer and drain the water from the cylindrical tube;
Remove the gloves and determine the results one by one: gloves without leakage are considered "qualified", and those with leakage are considered "unqualified";
Generate a test report using the equipment, recording sample information, test standards, and results for each test station.
7. Equipment Post-Maintenance
Clean any remaining water stains from the transparent cylindrical tube and the test station fixtures;
Check the operating status of the automatic liquid filling and clamping functions, organize and archive the test report, and ensure the stability of the equipment for future use.
在线联系供应商
Other supplier products
| Battery Membrane Breathability Test Machine JIS Standard | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) GB/T 458 – Battery diaphragm gas permeability test metho... | |
| Rubber Sleeve Rebound Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Rubber Sleeve Rebound Tester is designed to evaluate the resilience and compression per... | |
| Plastic Ball Indentation Hardness Measuring Device | Whats/App: +86 156 1874 6768 Web: standard-groups.com Scope of application: It is used to measure the characteristics of the plastic drainage pl... | |
| ISO / JIS crocking fastness tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Rubbing Color Fastness Tester is suitable for rubbing color fastness testi... | |
| ASTM F963 Toy Burning Tester for Certification Laboratories | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Feature 1.PLC control, timing precision, hu... |
Same products
| 不锈钢焊剂芯焊丝 E308T1-1 E308HT1-1 E308LT1-1 用于304不锈钢焊接的气保焊丝 | 卖方: 863048 | 产品描述 不锈钢药芯焊丝 E308T1-1 E308HT1-1 E308LT1-1,FCAW不锈钢焊丝,AWS A5.22药芯焊丝,304不锈钢焊接耗材,低碳不锈钢药芯焊丝,耐高温不锈钢焊丝,... | |
| E317LT1-1 焊剂芯线 CO2 不锈钢焊剂含量70% 直径1.0/1.2/1.6mm OEM定制 1200℃熔点 | 卖方: 863048 | 迅卓不锈钢药心焊丝 E317LT1-1 分类: Сварочная проволока E317LT1-1 с флюсом, нержавеющая сталь, 70% содержан... | |
| Mini Jewelry Laser Repair System – 60W to 400W Precision Welding | 卖方: Beijing JCZ Technology Co., Ltd | The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre... | |
| Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal | 卖方: Beijing JCZ Technology Co., Ltd | TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig... | |
| Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner | 卖方: Beijing JCZ Technology Co., Ltd | The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las... |