Garment Electromagnetic Radiation Shielding Performance Testing System

Getaquote:

Whats/App: +86 181 0160 0864

The Garment Electromagnetic Radiation Shielding Performance Testing System is a comprehensive testing solution designed to evaluate the shielding effectiveness of protective clothing against electromagnetic radiation. Using a microwave test manikin in a controlled semi-anechoic chamber, the system measures the attenuation of electromagnetic waves on the head, chest, and abdomen of a dressed manikin. By simulating real-life conditions, the system provides accurate, reproducible assessment of garments’ protective performance across different frequencies.

Application

The system is suitable for a wide range of applications:

Assessing electromagnetic shielding performance of protective clothing in research and development

Evaluating finished garments and critical raw materials for EMF protection

Supporting quality control in textile and wearable electronics industries

Verifying compliance of protective apparel used in industrial, medical, or military environments

Standards

The testing system supports compliance with the following standards:

GB 23463-2025 – Protective Clothing for Microwave Radiation

GB/T 33615-2017 – Methods for Testing Electromagnetic Shielding Performance of Garments

DIN 32780-100 – Protective Clothing, Part 100: Electromagnetic Field Protection in 80 MHz–1 GHz Range

IEC 61000-4-3 – Testing and Measurement Techniques for Radiated RF Electromagnetic Fields

ISO 105-X12 – Textiles: Color Fastness to Electromagnetic Effects (Reference for material durability)

Parameters

ParameterSpecification
Test Object Protective garments, including finished products and key raw materials
Test Environment Semi-anechoic chamber with low electromagnetic interference
Frequency Range 80 MHz – 1 GHz (standard)
Measurement Points Head, chest, abdomen of manikin
Sensors Embedded EMF receiving sensors in manikin
Radiation Source Signal amplifier with directional transmitting antenna
Shielding Effectiveness Measurement Vector Network Analyzer (VNA)
Environmental Conditions Controlled temperature and humidity to minimize measurement variability
Data Output Real-time attenuation curves and shielding performance reports
Power Supply AC 220V, 50/60 Hz
Footprint Chamber and system optimized for laboratory installation

Features

Realistic simulation of human exposure using test manikin

Semi-anechoic chamber minimizes external electromagnetic interference

High-precision vector network analyzer measures shielding effectiveness accurately

Multi-point measurement captures shielding at head, chest, and abdomen

Supports evaluation of raw materials, components, and finished garments

Integrated software for data acquisition, analysis, and automatic report generation

Capable of long-term performance evaluation including wash and abrasion tests

Accessories

Semi-anechoic chamber / electromagnetic shielded room

Microwave test manikin with embedded sensors

Vector Network Analyzer (VNA)

Signal amplifier with directional transmitting antenna

Environmental control sensors for temperature and humidity

Data acquisition and analysis software

Support fixtures for garment placement

Test Procedures

Sample Preparation

Include finished garments and critical raw materials to evaluate both overall and component-level shielding.

Ensure garments are properly mounted on the manikin with sensors correctly positioned.

Environmental Control

Conduct testing in a low-noise, semi-anechoic chamber to minimize external electromagnetic interference.

Measurement

Activate the electromagnetic radiation source and record real-time attenuation at head, chest, and abdomen using the manikin sensors.

Use the Vector Network Analyzer to measure shielding effectiveness across the target frequency range.

Durability Assessment

Optionally perform wash, friction, and other stress tests on the garment before re-evaluating shielding performance.

Data Recording

Analyze and record results with integrated software, generating performance curves and standardized reports.

Maintenance Information

Regularly inspect and calibrate the vector network analyzer and sensors to ensure accuracy

Maintain semi-anechoic chamber cleanliness and check shielding integrity periodically

Verify signal amplifier and antenna operation before each test

Ensure environmental sensors are functional and provide accurate temperature and humidity readings

Store manikin and sensitive components properly when not in use to prevent mechanical or electrical damage


在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Martindale Abrasion And Pilling Tester
Martindale Abrasion And Pilling Tester Getaquote: Whats/App: +86 181 0160 0864 Martindale Abrasion & Pilling Tester To determine the abrasion and pilling resistance of all kinds of...
Plastic Pipe Hydrostatic Pressure Burst Tester
Plastic Pipe Hydrostatic Pressure Burst Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Plastic Pipe Hydrostatic Pressure Burst Tester utilizes an international airle...
Solar Radiation Meters / Solar Radiation Sensors
Solar Radiation Meters / Solar Radiation Sensors Product Introduction: The purpose of this instrument is to measure the temperature change of the sample with radiant heat. Arrange the sample and...
Small Solar Simulator
Small Solar Simulator Getaquote: Whats/App: +86 181 0160 0864 TheSmall Solar Simulatoris a precision laboratory device designed for the controlled simulation of solar ...
Contact heating and cooling tester STD-F7
Contact heating and cooling tester STD-F7 Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Contact Heating and Cooling Tester (Thermo Labo) evaluates the sensation of co...
供应产品

Same products

HDPE高速水冷双壁波纹管生产线
HDPE高速水冷双壁波纹管生产线 卖方: Shandong HUASU Plastic Technology Co.,Ltd. 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功...
PanEVAP & MVR system
PanEVAP & MVR system 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...