Cabin Air Filter Test System(Particle removal & Gas adsorption)

Get a quote:
Whats/App: +86 181 0160 0864
Web: gellowen.co.uk
Test System for both particle separation and gas absorption/desorption of of air filters for passenger compartments (DIN 71460-1/2, ISO 11155-1/2). It povides a maximum of paramater testing for cabin air filters.
Applications
Fractional efficiency according to ISO 11155-1 (DIN 71460-1)
Gas adsorption tests according to ISO 11155-2 (DIN 71460-2)
Adsorption/desorption tests
Research and development tasks on automotive cabin air filters
Standards
GB/T 32085.1 — Automotive Air Conditioning Filters, Part 1: Dust Filtration Test
GB/T 32085.2 — Automotive Air Conditioning Filters, Part 2: Gas Filtration Test
DIN 71460-1 — Road Vehicles, Cabin Air Filters, Part 1: Particulate Filter Test
DIN 71460-2 — Road Vehicles, Cabin Air Filters, Part 2: Gas Filter Test
ISO/TS 11155-1 — Road Vehicles, In-Cabin Air Filters, Part 1: Dust Filtration Test
ISO 11155-2 — Road Vehicles, In-Cabin Air Filters, Part 2
ISO 10121-1 / ISO 10121-2 — General Methods for Air Filter Performance Testing
Features
standard compliant testing of filter media and filter elements
combined testing with particles and with gases
very flexible system configuration possible
Technical Data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 70 … 700 |
| Test aerosol | – | DEHS, DOP, PAO, KCl, NaCl, etc. |
| Test gases | – | n-Butane 80 ppm, Toluene 80 ppm, Sulfur dioxide 30 ppm, Hydrogen sulfide 10 ppm |
| Measuring range, differential pressure | Pa | 0 … 1000 (± 2 %) |
| Test specimen dimensions | mm | max. 600 × 300 |
| Operating medium (gas/air) | – | Room air at standard test conditions (23°C ± 2 K; 50 % ± 2 % RH) |
| Power supply | – | 400 VAC / 3P / 75 A / 50 … 60 Hz and 3 × 230 VAC / 2P / 16 A / 60 Hz |
| Aerosol generation technology | – | Dust disperser SAG 410/L, Atomizer ATM 220, etc. |
| Aerosol conditioning technology | – | Electrostatic Aerosol Neutralizer EAN 581 |
| Aerosol measurement instruments | – | Aerosol spectrometer LAP 322 |
| Gas analysers | – | FID, NDIR |
| Sensors (others) | – | Temperature, relative humidity, absolute pressure |
| System dimensions (W × H × D) | mm | 3700 × 3000 × 3700 |
在线联系供应商
Other supplier products
| Leather edge oil fatigue testing machine / Leather Fatigue Test Machine | Introduction: Leather edge oil is made of polyvinyl chloride and other resins, used to coat leather, recycled leather, artificial/a colored semi-l... | |
| Nail Bed Flammable Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The tester is used as test fixture in the flammability test of solid and soft toys... | |
| Liquid Autoignition Point Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Liquid Autoignition Point Tester is a device used to determine the lowest temp... | |
| Floor Caster Wear Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Floor Caster Wear Tester is designed to evaluate the wear resistance of chair ... | |
| Thermal Comfort Environmental Chamber | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Thermal Comfort Environmental Chamber is a high-precision climate simulation s... |
Same products
| Common Rail Injector Valve F00R J02 012 | 卖方: 868983 | Common Rail Injector Valve F00R J02 012 David Chen | |
| Common Rail Injector Valve F00R J02 005 | 卖方: 868983 | Common Rail Injector Valve F00R J02 005 David Chen | |
| Common Rail Injector Valve F00R J01 945 | 卖方: 868983 | Common Rail Injector Valve F00R J01 945 David Chen | |
| Common Rail Injector Valve F00R J01 941 | 卖方: 868983 | Common Rail Injector Valve F00R J01 941 David Chen | |
| Common Rail Injector Valve F00R J01 924 | 卖方: 868983 | Common Rail Injector Valve F00R J01 924 David Chen |