NES 713 Smoke Toxicity Tester, Toxic Gas Analyzer, Marine Fire Testing Equipment Manufacturer

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Parameters

ParameterSpecification
Flame height 100–125 mm (blue flame)
Maximum hot spot temperature 1150 ± 25 °C
Number of sampling ports 12
Exhaust capacity ≥ 50 L/s
Gas supply Compressed air, methane or natural gas
Power supply AC 220 V, 50/60 Hz, 5 A
Equipment weight Approx. 150 kg
Overall dimensions 1.185 (W) × 700 (D) × 2.100 (H) mm

Features

Rigid steel chamber with reinforced frame construction to ensure long-term structural stability

Large observation window with dark-coated inner walls to clearly observe the combustion behavior of specimens

Inner chamber walls treated with PTFE coating to reduce chemical corrosion caused by combustion gases

Built-in stirring fan to ensure uniform distribution of smoke and combustion gases inside the chamber

Top-mounted exhaust fan with stainless steel exhaust duct, automatically activated after test completion to discharge residual smoke

Integrated industrial design with panel-mounted structure, providing intuitive operation and ergonomic human–machine interface

High-voltage pulse automatic ignition system offering stable ignition performance and enhanced operational safety

Imported K-type thermocouples for accurate and reliable temperature measurement

Adjustable stainless steel specimen mesh tray allowing precise positioning relative to the flame

Imported precision rotameters for accurate control of gas and air flow rates

Branded pressure gauges, pressure regulators, and solenoid valves to control gas pressure and on/off status, ensuring safe operation

PLC and touchscreen control system enabling automatic control, detection, calculation, and data storage

Automatic waste exhaust mode to remove smoke upon test completion according to preset program logic

Manual and automatic test modes selectable to suit different testing requirements

Test Procedures

1. Pre-Test Preparation

Environment confirmation:

The test area should be an independent, well-ventilated space, kept away from flammable materials and densely populated areas. The floor must be dry and free of standing water. The power supply should be properly grounded and meet AC 220 V, 50/60 Hz, 5 A requirements.

Equipment inspection:

Check all gas pipelines (methane or natural gas) for leakage and confirm the gas cylinder pressure is within 0.2–0.3 MPa. Verify that the exhaust fan and stainless steel exhaust duct are unobstructed and capable of providing an exhaust capacity of at least 50 L/s. Confirm normal operation of the K-type thermocouples, rotameters, and PLC touchscreen with no alarm indications. Ensure proper door sealing, intact polycarbonate observation window, and undamaged PTFE inner wall coating.

Safety protection:

Operators should wear high-temperature resistant gloves, safety goggles, gas masks equipped for CO and HCN protection, and safety shoes. A portable multi-gas detector (monitoring O₂, CO, HCN, NOₓ) and an emergency eyewash station should be available on site.

2. Specimen Installation

Specimens should conform to NES 713 requirements, typically measuring 100 mm × 100 mm with a thickness not exceeding 10 mm. Cable materials may be fixed using a coiled arrangement. No more than three specimens should be tested in a single run, evenly distributed on the stainless steel mesh tray to avoid flame obstruction. Adjust the tray position so that it is located directly above the burner, with a distance of 100–125 mm from the burner nozzle to ensure full flame coverage on the specimen underside.

3. Ignition and Test Execution

Close the chamber door and confirm the locking mechanism is engaged. Select “Automatic Mode” on the control screen and start the test. The system will automatically perform high-voltage pulse ignition for approximately three seconds, followed by flame stability detection. If a stable flame is not detected within five seconds, re-ignition will be attempted automatically, up to three times. The combustion process typically lasts 10–15 minutes, during which the internal fan continuously mixes smoke to maintain uniform concentration.

4. Gas Sampling

Gas sampling begins at the fifth minute after ignition and continues until the end of combustion. Twelve dedicated sampling ports are used to connect gas detector tubes (for gases such as HCN, CO, and HCl) or online gas analyzers. Each sampling port is equipped with an independent flow meter, with the sampling flow rate controlled at no more than 1 L/min to avoid negative pressure interference. After sampling, tubes are sealed immediately, labeled with time and port number, and sent for quantitative laboratory analysis.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Custom Syringe needle flow tester
Custom Syringe needle flow tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is suitable for a wide range of medical devices, including: (1) D...
Contact cooling characteristic tester
Contact cooling characteristic tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application You can apply this tester to: (1) Instantaneous cool sensation evaluation of ...
Metal Wire Wrap Tester
Metal Wire Wrap Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com According to the criteria: GB/T 2976 "Wire winding test method for Metal Materials" ISO 4...
Lithium battery explosion test chamber,IEC 60086,UL 913
Lithium battery explosion test chamber,IEC 60086,UL 913 Whats/App: +86 156 1874 6768 Web: standard-groups.com Lithium battery combustion and explosion experiment chamber is mainly used for thermal runa...
Heat Flow Meter for Thermal Insulation Materials ASTM C518 Testing
Heat Flow Meter for Thermal Insulation Materials ASTM C518 Testing Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM C518: Standard Test Method for Steady-State Thermal Transmiss...
供应产品

Same products

不锈钢焊剂芯焊丝 E308T1-1 E308HT1-1 E308LT1-1 用于304不锈钢焊接的气保焊丝
不锈钢焊剂芯焊丝 E308T1-1 E308HT1-1 E308LT1-1 用于304不锈钢焊接的气保焊丝 卖方: 863048 产品描述 不锈钢药芯焊丝 E308T1-1 E308HT1-1 E308LT1-1,FCAW不锈钢焊丝,AWS A5.22药芯焊丝,304不锈钢焊接耗材,低碳不锈钢药芯焊丝,耐高温不锈钢焊丝,...
E317LT1-1 焊剂芯线 CO2 不锈钢焊剂含量70% 直径1.0/1.2/1.6mm OEM定制 1200℃熔点
E317LT1-1 焊剂芯线 CO2 不锈钢焊剂含量70% 直径1.0/1.2/1.6mm OEM定制 1200℃熔点 卖方: 863048 迅卓不锈钢药心焊丝 E317LT1-1 分类: Сварочная проволока E317LT1-1 с флюсом, нержавеющая сталь, 70% содержан...
Mini Jewelry Laser Repair System – 60W to 400W Precision Welding
Mini Jewelry Laser Repair System – 60W to 400W Precision Welding 卖方: Beijing JCZ Technology Co., Ltd The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre...
Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal
Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal 卖方: Beijing JCZ Technology Co., Ltd TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig...
Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner
Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner 卖方: Beijing JCZ Technology Co., Ltd The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las...