Air Intake Filter Test System Manufacturer | ISO 16890 & ISO 29461 Filtration Performance Testing Equipment
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Parameters
| Parameter | Unit | Value |
|---|---|---|
| Test Flow Rate | m³/min | 2 … 50 (at 20°C and 1013 hPa) |
| Differential Pressure Measuring Range | Pa | ≤ 15.000 |
| Compressed Air Supply | bar | 6 |
| Power Supply | – | 400 VAC, 125 A |
| Test Aerosol | – | ISO 12103-1 A2 (fine), ISO 12103-1 A4 (coarse) |
Features
Powerful Two-Stage Flow Generation: Provides stable and adjustable airflow for a wide range of filters.
Precise Flow Rate Measurement: Flow adjustable for each application and standard.
Mass Flow Regulated Dust Dosing: Ensures accurate dust loading for consistent testing.
High Automation: Test runs are mostly automated, including data collection, operator guidance, and report generation.
Comprehensive Filter Evaluation: Measures differential pressure, airflow restriction, dust loading, gravimetric efficiency, and downstream particle size distribution.
Accessories
| Accessory | Description |
|---|---|
| Water Injection System | For humidification and testing under specific conditions |
| Water Separators | Ensures clean airflow and prevents moisture interference |
| Additional Pressure Sensors | Measure complete air inlet system pressure |
| Particle Measurement | Downstream particle counting for efficiency assessment |
| Scavenging Line | Removes residual dust and ensures safe operation |
Test Principle
The system draws a controlled airflow through the filter sample while injecting standardized dust (ISO 12103-1). Differential pressure, airflow restriction, dust loading, and gravimetric efficiency are continuously measured. Downstream particle counters monitor the filtration efficiency in real time. The system automatically adjusts dust dosing and flow rate to achieve repeatable and standardized results.
Operation Instructions
Safety:
Ensure proper connection of electrical and compressed air supplies.
Maintain ventilation during aerosol use.
Use personal protective equipment when handling dust or testing high-flow systems.
Setup:
Mount filter sample securely using the appropriate adapter.
Select aerosol type and configure flow and differential pressure settings.
Calibrate sensors before each test cycle.
Testing:
Start the automated test sequence.
The system regulates flow, dust dosing, and monitors differential pressure.
Data are recorded and saved automatically for analysis.
Post-Test:
Analyze differential pressure curves, dust loading, gravimetric efficiency, and particle size data.
Generate standardized reports for quality control and certification purposes.
在线联系供应商
Other supplier products
| Catheter Guidewire Friction Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Guidewire Friction Tester is designed to accurately measure the frictional for... | |
| Perforated leather abrasion tester for automotive interiors | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards Standard CodeDescription TIS 01208-00F21 Toyota Perforated Leather A... | |
| Incline Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Incline Impact Tester is designed to evaluate the impact resistance of products, packag... | |
| Sanitary Napkin Absorption Rate Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main uses: The absorption speed tester is used to measure the absorption speed of sanitary... | |
| Fabric Fiber Shedding Degree Tester (Friction) | Whats/App: +86 156 1874 6768 Web: standard-groups.com Instrument Testing Principle Lay the specimen flat and fix it on the holder. Make the wet ... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |