.

DIN 51524 hydraulic oil analyzer

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

You can operate this unit in compliance with the following standards:

(1) GB/T 18854-2015 – Hydraulic transmission: Determination of solid particle contamination levels in hydraulic oil;

(2) GB/T 14039-2002 – Hydraulic transmission: Oil contamination control and monitoring;

(3) GB/T 4207-2012 – Determination of water content in mineral-based lubricating oils;

(4) ISO 4406:2017 – Hydraulic fluid power: Coding of solid particle contamination levels;

(5) ISO 4407:2002 – Hydraulic fluid power: Particle counting method for contamination measurement;

(6) ISO 9110:1990 – Hydraulic fluid power: Filter performance test methods.

Parameters

ParameterUnitValue
Rated Flow L/min 40 / 100 / 150
Rated Pressure MPa 0.6
Initial Pressure Loss MPa ≤ 0.2
Coarse Filter Precision μm 100
First-Stage Filter Precision μm 25 / 40
Second-Stage Filter Precision μm 3 / 5 / 10
Motor Power kW 1.1 + 0.75 / 2.2 + 1.1 / 4 + 1.1
Power Supply V AC 380

Features

Dual-motor driven gear pump ensures smooth operation, low noise, strong self-priming, and stable performance.

High-pressure piping is equipped with overflow protection to prevent overpressure operation.

Thermal relay protection prevents motor overload and damage.

Suction inlet equipped with a coarse filter protects the pump and extends the life of precision filters.

Two-stage precision filtration rapidly improves oil cleanliness.

Filter precision is selectable to meet different operating conditions.

Integrated panel pressure gauges allow real-time monitoring of system status and filter contamination.

Accessories

(1) Dedicated Gear Pump – Dual pump configuration for stable flow.

(2) Coarse Filter – 100 μm.

(3) First-Stage Precision Filter – 25 μm / 40 μm.

(4) Second-Stage Precision Filter – 3 μm / 5 μm / 10 μm.

(5) Motor – Dual-motor drive.

(6) Pressure Gauge – System pressure monitoring.

(7) Overflow Valve – Overpressure protection.

(8) Heating System – Independent heating module for low-temperature operation.

(9) Consumable Filter Elements – Replaceable as needed.

Test Procedures

Ensure oil hoses are connected correctly and inlet/outlet valves are open.

Check power supply, motor status, and protection devices.

In low-temperature environments, start the heating system to bring oil to the required viscosity before operation.

Monitor pressure gauges during operation to avoid overpressure.

Replace filter elements promptly if the differential pressure rises significantly.

Before shutdown, close the inlet valve, depressurize the system, and then cut off the power.

Maintenance Information

Regularly inspect hoses, filter elements, and protection devices for wear or damage.

Replace filter elements according to operating hours or differential pressure readings.

Clean the system periodically to prevent sediment buildup.

Verify operation of the heating system and overflow protection before each use.

Record operation data to monitor system performance over time.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Gas Explosion Pressure Test Apparatus,ISO 10156  combustible gas explosion test apparatus
Gas Explosion Pressure Test Apparatus,ISO 10156 combustible gas explosion test apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com The Gas Explosion Pressure Test Apparatus is designed to measure the explosion characterist...
Testing apparatus for back and butt forms evaluation
Testing apparatus for back and butt forms evaluation Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com 5th Percentile Female SAE Butt Form The 5th Percentile Female SAE Butt Form ...
Suture Needle Cutting Force Tester
Suture Needle Cutting Force Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Suture Needle Cutting Force Tester is a precision instrument specifically used to detec...
Micro Rapid Closed Cup Flash Point Tester(Pensky Martens)
Micro Rapid Closed Cup Flash Point Tester(Pensky Martens) Whats/App: +86 156 1874 6768 Web: standard-groups.com Automatic Flash Point Tester designed for accurate and repeatable determination of the flas...
Yellowing resistance chamber
Yellowing resistance chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable standards HG/T3986. ASTM D1748. etc. Scope of application Test method for det...
供应产品

Same products

Filter Efficiency Testing Equipment
Filter Efficiency Testing Equipment 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com TheFilter Efficiency Testing Equipmentis ...
G506 Filter Performance Tester
G506 Filter Performance Tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM F2100:Standard Specificat...
Automated Filter Integrity Tester
Automated Filter Integrity Tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Testing Standards ASTM F838 – Memb...
High Efficiency Oil Water Separation Tester
High Efficiency Oil Water Separation Tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO/TS 16332-2006 – Meth...
DIN 51524 hydraulic oil analyzer
DIN 51524 hydraulic oil analyzer 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards You can operate this unit in c...