MemoPart™ Atrial Septal Defect (ASD) Occluder
MemoPart™
Accurate occluding, stable clamping
MemoPart™ Atrial Septal Defect (ASD) Occluder Details
ASD occluder deviceDescription
MemoPart™ ASD Occluderis a self-expanding double-disc nitinol mesh occlusion device. The 2 discs are connected by a short waist that relates to the defect size. Polyester fabric is securely sewn to each disc to increase occlusion. The device is visible under X-ray.
ASD occluder device Features
Modified rigidity and flexibility for different type of occluders - greater stiffness of Atrial Septal Defect Occluder (ASDO) offers excellent supporting force for big disks.
Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.
The hubless design of Atrial Septal Defect Occluder (ASDO) helps with earlier endothelialization to minimize the risk of thrombosis.
Indications for Use ASD Occlusion Device
The MemoPart™ ASD Occluder is a percutaneous, transcatheter, atrial septal defect closure device intended for the occlusion of atrial septal defects (ASD)in secundum position or patients who have undergone a fenestrated Fontan procedure and who require closure of the fenestration.
Patients indicated for ASD closure have echocardiographic evidence of ostium secundum atrial septal defect and clinical evidence of right ventricular volume overload(i.e.,1.5:1 degree of left-to-right shunt or RV enlargement ).
Ordering Information
Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
DeviceSiz |
AWaistDiameter(mm) |
B LA Disc Diameter (mm) |
CRA DiscDiameter(mm) |
HWaistLength(mm) |
|
FQFDQ- Ⅰ 06 |
6 |
6 |
16 |
14 |
3 |
|
FQFDQ- Ⅰ 07 |
7 |
7 |
21 |
17 |
3 |
|
FQFDQ- Ⅰ 08 |
8 |
8 |
18 |
16 |
3 |
|
FQFDQ- Ⅰ 09 |
9 |
9 |
23 |
19 |
3 |
|
FQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
FQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
FQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
FQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
FQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
FQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
FQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
FQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
FQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
FQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
FQFDQ- Ⅰ 20 |
20 |
20 |
34 |
30 |
4 |
|
FQFDQ- Ⅰ 22 |
22 |
22 |
36 |
32 |
4 |
|
FQFDQ- Ⅰ 24 |
24 |
24 |
38 |
34 |
4 |
|
FQFDQ- Ⅰ 26 |
26 |
26 |
40 |
36 |
4 |
|
FQFDQ- Ⅰ 28 |
28 |
28 |
42 |
38 |
4 |
|
FQFDQ- Ⅰ 30 |
30 |
30 |
44 |
40 |
4 |
|
FQFDQ- Ⅰ 32 |
32 |
32 |
47 |
42 |
4 |
|
FQFDQ- Ⅰ 34 |
34 |
34 |
49 |
44 |
4 |
|
FQFDQ- Ⅰ 36 |
36 |
36 |
51 |
46 |
4 |
|
FQFDQ- Ⅰ 38 |
38 |
38 |
54 |
50 |
|
|
FQFDQ- Ⅰ 40 |
40 |
40 |
56 |
52 |
|
|
FQFDQ- Ⅰ 42 |
42 |
42 |
58 |
54 |
|
|
FQFDQ- Ⅰ 44 |
44 |
44 |
60 |
56 |
|
|
FQFDQ- Ⅰ 46 |
46 |
46 |
62 |
58 |
|
|
FQFDQ- Ⅰ 48 |
48 |
48 |
64 |
60 |
|
|
FQFDQ- Ⅰ 50 |
50 |
50 |
66 |
62 |
Hubless Atrial Septal Defect (ASD) Occluder
|
Catalogue No. Device |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
WTFQFDQ- Ⅰ 06 |
06 |
6 |
16 |
14 |
3 |
|
WTFQFDQ- Ⅰ 07 |
07 |
7 |
21 |
17 |
3 |
|
WTFQFDQ- Ⅰ 08 |
08 |
8 |
18 |
16 |
3 |
|
WTFQFDQ- Ⅰ 09 |
09 |
9 |
23 |
19 |
3 |
|
WTFQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
WTFQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
WTFQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
WTFQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
WTFQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
WTFQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
WTFQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
WTFQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
WTFQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
WTFQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
WTFQFDQ- Ⅰ 20 |
20 |
20 |
34 |
30 |
4 |
|
WTFQFDQ- Ⅰ 22 |
22 |
22 |
36 |
32 |
4 |
|
WTFQFDQ- Ⅰ 24 |
24 |
24 |
38 |
34 |
4 |
Multi-Fenestrated Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
FQFDQ- Ⅱ 06 |
6 |
6 |
30 |
22 |
3 |
|
FQFDQ- Ⅱ 08 |
8 |
8 |
32 |
24 |
3 |
|
FQFDQ- Ⅱ 10 |
10 |
10 |
34 |
26 |
3 |
|
FQFDQ- Ⅱ 12 |
12 |
12 |
36 |
28 |
3 |
|
FQFDQ- Ⅱ 14 |
14 |
14 |
38 |
30 |
3 |
|
FQFDQ- Ⅱ 16 |
16 |
16 |
40 |
32 |
4 |
|
FQFDQ- Ⅱ 18 |
18 |
18 |
42 |
34 |
4 |
|
FQFDQ- Ⅱ 20 |
20 |
20 |
44 |
36 |
4 |
|
FQFDQ- Ⅱ 22 |
22 |
22 |
46 |
38 |
4 |
|
FQFDQ- Ⅱ 24 |
24 |
24 |
48 |
40 |
4 |
Hubless Multi-Fenestrated Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
WTFQFDQ- Ⅱ 06 |
6 |
6 |
30 |
22 |
|
|
WTFQFDQ- Ⅱ 08 |
8 |
8 |
32 |
24 |
|
|
WTFQFDQ- Ⅱ 10 |
10 |
10 |
34 |
26 |
|
|
WTFQFDQ- Ⅱ 12 |
12 |
12 |
36 |
28 |
|
|
WTFQFDQ- Ⅱ 14 |
14 |
14 |
38 |
30 |
As one of medical devices suppliers, we can offer sorts of medical devices chinafor sale, anything you need, please leave us a message.
在线联系供应商
Other supplier products
| LFR30B Infrared Forehead Thermometer | Blue dots focusing calibration system help users to find the optimal measuring distance LFR30B medical infrared forehead thermometer are designed f... | |
| Disposable Hemodialysis Catheter Kit | Disposable catheterkit is intended for intervention in the blood vessels (through femoral vein, internal jugular vein or subclavian vein as require... | |
| PC-1000 Central Monitoring Station | Central Patient Monitoring Please note: this product is currently not authorized for sale or distribution in the U.S. It's strictly forbidden to a... | |
| Deliver™ Infusion Catheter | Deliver™ Infusion Catheter Deliver™ Infusion CatheterDetails Combined liquid perfusion lumen and guide wire lumen fulfills the per... | |
| LFR60 Infrared Forehead Thermometer | LFR60B handheld forehead thermometeris a non-contact digital infrared thermometer for fever. It is suitable for different users, such as babies, ch... |
Same products
| Medical Disposable Iv Infusion Set Iv Drip Set | 卖方: Hebei Zongkai Technology Co., LTD | Customization options Customized logo(Min. order: 100000 units) Customize... | |
| Air Permeability Tester STD- F8 | 卖方: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | 卖方: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | 卖方: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | 卖方: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... |