MemoPart™ Atrial Septal Defect (ASD) Occluder
MemoPart™
Accurate occluding, stable clamping
MemoPart™ Atrial Septal Defect (ASD) Occluder Details
ASD occluder deviceDescription
MemoPart™ ASD Occluderis a self-expanding double-disc nitinol mesh occlusion device. The 2 discs are connected by a short waist that relates to the defect size. Polyester fabric is securely sewn to each disc to increase occlusion. The device is visible under X-ray.
ASD occluder device Features
Modified rigidity and flexibility for different type of occluders - greater stiffness of Atrial Septal Defect Occluder (ASDO) offers excellent supporting force for big disks.
Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.
The hubless design of Atrial Septal Defect Occluder (ASDO) helps with earlier endothelialization to minimize the risk of thrombosis.
Indications for Use ASD Occlusion Device
The MemoPart™ ASD Occluder is a percutaneous, transcatheter, atrial septal defect closure device intended for the occlusion of atrial septal defects (ASD)in secundum position or patients who have undergone a fenestrated Fontan procedure and who require closure of the fenestration.
Patients indicated for ASD closure have echocardiographic evidence of ostium secundum atrial septal defect and clinical evidence of right ventricular volume overload(i.e.,1.5:1 degree of left-to-right shunt or RV enlargement ).
Ordering Information
Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
DeviceSiz |
AWaistDiameter(mm) |
B LA Disc Diameter (mm) |
CRA DiscDiameter(mm) |
HWaistLength(mm) |
|
FQFDQ- Ⅰ 06 |
6 |
6 |
16 |
14 |
3 |
|
FQFDQ- Ⅰ 07 |
7 |
7 |
21 |
17 |
3 |
|
FQFDQ- Ⅰ 08 |
8 |
8 |
18 |
16 |
3 |
|
FQFDQ- Ⅰ 09 |
9 |
9 |
23 |
19 |
3 |
|
FQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
FQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
FQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
FQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
FQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
FQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
FQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
FQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
FQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
FQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
FQFDQ- Ⅰ 20 |
20 |
20 |
34 |
30 |
4 |
|
FQFDQ- Ⅰ 22 |
22 |
22 |
36 |
32 |
4 |
|
FQFDQ- Ⅰ 24 |
24 |
24 |
38 |
34 |
4 |
|
FQFDQ- Ⅰ 26 |
26 |
26 |
40 |
36 |
4 |
|
FQFDQ- Ⅰ 28 |
28 |
28 |
42 |
38 |
4 |
|
FQFDQ- Ⅰ 30 |
30 |
30 |
44 |
40 |
4 |
|
FQFDQ- Ⅰ 32 |
32 |
32 |
47 |
42 |
4 |
|
FQFDQ- Ⅰ 34 |
34 |
34 |
49 |
44 |
4 |
|
FQFDQ- Ⅰ 36 |
36 |
36 |
51 |
46 |
4 |
|
FQFDQ- Ⅰ 38 |
38 |
38 |
54 |
50 |
|
|
FQFDQ- Ⅰ 40 |
40 |
40 |
56 |
52 |
|
|
FQFDQ- Ⅰ 42 |
42 |
42 |
58 |
54 |
|
|
FQFDQ- Ⅰ 44 |
44 |
44 |
60 |
56 |
|
|
FQFDQ- Ⅰ 46 |
46 |
46 |
62 |
58 |
|
|
FQFDQ- Ⅰ 48 |
48 |
48 |
64 |
60 |
|
|
FQFDQ- Ⅰ 50 |
50 |
50 |
66 |
62 |
Hubless Atrial Septal Defect (ASD) Occluder
|
Catalogue No. Device |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
WTFQFDQ- Ⅰ 06 |
06 |
6 |
16 |
14 |
3 |
|
WTFQFDQ- Ⅰ 07 |
07 |
7 |
21 |
17 |
3 |
|
WTFQFDQ- Ⅰ 08 |
08 |
8 |
18 |
16 |
3 |
|
WTFQFDQ- Ⅰ 09 |
09 |
9 |
23 |
19 |
3 |
|
WTFQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
WTFQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
WTFQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
WTFQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
WTFQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
WTFQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
WTFQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
WTFQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
WTFQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
WTFQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
WTFQFDQ- Ⅰ 20 |
20 |
20 |
34 |
30 |
4 |
|
WTFQFDQ- Ⅰ 22 |
22 |
22 |
36 |
32 |
4 |
|
WTFQFDQ- Ⅰ 24 |
24 |
24 |
38 |
34 |
4 |
Multi-Fenestrated Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
FQFDQ- Ⅱ 06 |
6 |
6 |
30 |
22 |
3 |
|
FQFDQ- Ⅱ 08 |
8 |
8 |
32 |
24 |
3 |
|
FQFDQ- Ⅱ 10 |
10 |
10 |
34 |
26 |
3 |
|
FQFDQ- Ⅱ 12 |
12 |
12 |
36 |
28 |
3 |
|
FQFDQ- Ⅱ 14 |
14 |
14 |
38 |
30 |
3 |
|
FQFDQ- Ⅱ 16 |
16 |
16 |
40 |
32 |
4 |
|
FQFDQ- Ⅱ 18 |
18 |
18 |
42 |
34 |
4 |
|
FQFDQ- Ⅱ 20 |
20 |
20 |
44 |
36 |
4 |
|
FQFDQ- Ⅱ 22 |
22 |
22 |
46 |
38 |
4 |
|
FQFDQ- Ⅱ 24 |
24 |
24 |
48 |
40 |
4 |
Hubless Multi-Fenestrated Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
WTFQFDQ- Ⅱ 06 |
6 |
6 |
30 |
22 |
|
|
WTFQFDQ- Ⅱ 08 |
8 |
8 |
32 |
24 |
|
|
WTFQFDQ- Ⅱ 10 |
10 |
10 |
34 |
26 |
|
|
WTFQFDQ- Ⅱ 12 |
12 |
12 |
36 |
28 |
|
|
WTFQFDQ- Ⅱ 14 |
14 |
14 |
38 |
30 |
As one of medical devices suppliers, we can offer sorts of medical devices chinafor sale, anything you need, please leave us a message.
Send product request
Other supplier products
| Molecular Diagnostics | Types of Molecular Diagnostics Fully Automated Nucleic Acid Extractor We offer a wide range of Fully Automated Nucleic Acid Extractors with hig... | |
| CFMS LEPU-8880 | Features Fast, accurate, convenient and intelligent. Evaluate the prenatal prothrombotic state and prepare the essential treatment as early as ... | |
| Macitentan | Item/Code CAS No. Therapeutic Area Certification/Stage API Hypertension US - DMF No.31658 China - YI) As a macitentan manufacturer and opsumit m... | |
| SARS-CoV-2 Antibody Test Kit (Colloidal Gold Immunochromatography) | Accurate: High-purity antibody with high accuracy Efficient: Test result is available in 15mins Convenient: Suitable for finger blood Plea... | |
| PC-60A Fingertip Oximeter | Features Measuring SpO2, PR with Pulse bar Special design with splash-proof and drop-resistant Audible alarm with low battery indication 2 direc... |
Same products
| Full-Body Garment Stress Tester,FZ/T 70015 | Seller: Standard International Group (HK) Limited | TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe... | |
| Industrial Dry Cleaning Machine,industrial garment steamer | Seller: Standard International Group (HK) Limited | TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel... | |
| MST Medical Compression Stocking Tester,compression sock tester | Seller: Standard International Group (HK) Limited | The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the... | |
| MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool | Seller: Standard International Group (HK) Limited | Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi... | |
| Dental material color stability tester | Seller: Standard International Group (HK) Limited | Application The applications of color stability testers for dental materials are mainly reflecte... |