Oxidizing liquid time pressure tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Conforms to UN Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria 11.6.1 Test 1(c)(i): Time/Pressure Test, 12.6.1 Test 2(c)(i): Time/Pressure Test, 23.4.1 Test C.1: Time/Pressure Test, and GB/T 21579-2008 Time/Pressure Test Method for Dangerous Goods.
Applications
The Oxidizing Liquid Time Pressure Tester is used to determine the potential of a liquid substance to increase the combustion rate or intensity of a combustible substance when mixed with it.
Standards
GB/T 21620:Dangerous goods - Test methods for oxidizing liquids
GB/T 21579-2008:Dangerous goods - Test method of time/pressure
NY/T 1860:Guidelines on the determination of physico-chemical properties of pesticides
Features
1) Embedded processor, Windows CE operating system
2) 8-inch LCD touch screen can display the test status in real time
3) Automatic detection of pressure vessel air tightness (by detecting the initial pressure drop rate)
4) With ignition sound and light alarm function
5) Stainless steel seamless welded inner liner and pressure vessel, pressure sensor with corrosion resistance, high temperature resistance, high pressure resistance
6) Automatic timing and high-precision pressure detection system, real-time detection and display of pressure changes
7) With automatic pressure relief device, after the test, automatically punctured explosion-proof sheet, release pressure
8) Automatically draw the pressure curve
9) With reaction residue collection and anti-splash function to avoid external contamination of the sample
10) Remote ignition to ensure the safety of experimental personnel
11) The test process is fully automated without manual intervention, supporting parameter setting, data storage, viewing reports and other functions
Technical Parameters
|
Operating Environment |
(5 to 40)°C, <85%RH |
|
Pressure Transducer Response Capability |
Responds to pressure change from 0MPa-3MPa vessel cavity in 5ms |
|
Pressure Measurement Range |
(0 to 5)MPa |
|
Pressure Measurement Accuracy |
±0.1%FS |
|
Heating Method |
Electronic Ignition |
|
Burst Pressure of Rupture Disk |
2.5MPa ±5% |
|
Standard Timing Range |
(0 to 60)s |
|
Timing Display Resolution |
0.01ms |
Accessoriess
1. Core Working Components
Pressure Testing Unit:
Stainless steel seamless welded liner + pressure vessel (corrosion resistant, high temperature resistant, provides the necessary sealing environment for testing, conforms to UN/GB standards);
Corrosion resistant and high temperature resistant pressure sensor (real-time acquisition of pressure data within the vessel, supports time-pressure curve recording).
Control and Display Components:
Embedded processor (equipped with Windows CE operating system);
8-inch LCD touchscreen (real-time display of test status and time-pressure curve).
Functional Modules:
Automatic pressure vessel airtightness detection component (determines sealing status based on initial pressure drop rate);
Ignition audible and visual alarm device (triggers warning in case of test abnormalities).
2. Auxiliary Accessories
Sample Handling:
Pipette/Quantitative Sampler (accurately measures oxidizing liquid samples),
Dedicated liquid sample container (compatible with pressure vessel loading);
Calibration and Maintenance:
Pressure calibration standard device (calibrates pressure sensor accuracy),
Dedicated cleaning agent + cleaning brush (cleans pressure vessel liner);
Data Management:
USB flash drive (exports test data, time-pressure curve, and reports).
Test Procedures
1. Sample Preparation: Homogenize the oxidizing liquid sample to be tested (e.g., by stirring) to ensure no stratification and no impurities.
Measure the specified volume of sample according to the corresponding standard requirements using a pipette/quantitative sampler, and set aside.
2. Instrument Preparation: Connect the power supply and start the instrument. The embedded processor will automatically complete a fault self-check.
Access the calibration interface via the 8-inch touchscreen and calibrate the pressure sensor using the pressure calibration standard device.
Activate the airtightness detection module to automatically detect the sealing status of the pressure vessel (if the initial pressure drop rate meets the standard requirements, it passes).
3. Sample Loading and Sealing: Load the quantified liquid sample into the dedicated sample container inside the pressure vessel.
Close and lock the pressure vessel to ensure the cavity is completely sealed.
4. Parameter Setting and Test Start: Select the corresponding test standard (e.g., UN Test 1 (c)/GB/T on the touchscreen and set parameters such as the test duration.
Click "Start," and the instrument will automatically begin the test. The touchscreen will simultaneously display pressure changes and test progress. 5. Test Monitoring and Recording
During the test, if abnormal pressure fluctuations occur, the audible and visual alarm will be automatically triggered.
After the test, the instrument will automatically record key data such as the time-pressure curve, peak pressure, and pressure rise rate.
6. Completion and Data Export
After the pressure vessel has cooled and depressurized, open the chamber and clean the lining and sample container.
Export the test data and report to a USB flash drive via the touchscreen.
Turn off the instrument power to complete the operation.
在线联系供应商
Other supplier products
| Electric bicycle lighting device testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com An electric bicycle lighting device testing machine is a piece of equipment used to test th... | |
| Industrial Oven for Batteries | Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1.Real-time temperature monitoring, temperature range can be customi... | |
| Falling Sand Abrasion Test machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The sand abrasion tester is a specialized testing device used to evaluate the abrasion resi... | |
| Guidewires Tip Flexibility Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Uses The guidewire tip flexibility tester is a specialized device used to evaluate th... | |
| Cable and fiber optic cable line integrity combustion testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Cable and Fiber Optic Cable Line Integrity Combustion Testing Machine is designed to ev... |
Same products
| KL‑016A Benchtop High‑precision pH Meter | 卖方: 科立龙电子股份有限公司ctron Co.Ltd | Product Description: Large‑screen display with high resolution and precision for con... | |
| Large Naïve VHH Library | 卖方: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... |