Contact Lens Oxygen Permeability Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Contact Lens Oxygen Permeability Tester (Polarography Method) is a precision instrument designed to measure the oxygen permeability (Dk) of soft and hard contact lenses, hydrogel, silicone hydrogel, and other high oxygen permeability materials. The instrument provides accurate, repeatable measurements critical for lens manufacturers, laboratories, and research institutions. A complete measurement setup typically includes the main host, electrode assembly frame, electrodes, central thickness gauge, and a controlled temperature and humidity environment, ensuring compliance with international and national standards.
Application
(1) Measurement of oxygen permeability of soft contact lenses (hydrogel, silicone hydrogel).
(2) Evaluation of oxygen permeability in rigid or hard contact lenses.
(3) Quality control of contact lenses in manufacturing facilities.
(4) Research and development of new lens materials with enhanced oxygen permeability.
(5) Verification of compliance with regulatory standards for ophthalmic products.
(6) Laboratory testing of lens prototypes for performance evaluation.
Standards
(1) ISO 18369 – Ophthalmic optics – Contact lenses – Requirements and test methods.
(2) GB/T 11417 – Contact lens oxygen permeability measurement.
(3) ANSI Z80.20 – American National Standard for Contact Lens Oxygen Permeability.
(4) ISO 9913-1 – Ophthalmic materials – Oxygen permeability of polymer materials.
(5) ISO 9913-2 – Ophthalmic materials – Polarographic method for Dk measurement.
Features
(1) Dual input design supports simultaneous measurement of two test electrodes.
(2) Polarographic measurement ensures high accuracy and reproducibility.
(3) Compatible with soft, hard, hydrogel, silicone hydrogel, and other high Dk lenses.
(4) Complete system integration with host, electrode assembly, central thickness gauge, and temperature/humidity control.
(5) Precision temperature control (0.0–50.0°C) with 0.1°C resolution and ±0.2°C accuracy.
(6) Adjustable electrode excitation voltage (0.750 VDC) for polarographic measurements.
(7) Current measurement range with multiple gear options for low- and high-permeability lenses.
(8) Compact and portable design suitable for laboratory use.
Technical Parameters
| Parameter | Specification |
|---|---|
| Dual Input | Supports 2 test electrodes simultaneously |
| Power Supply | 210–250V AC, 5 W |
| Temperature Control | 0.0–50.0°C (Resolution 0.1°C, Accuracy ±0.2°C) |
| Electrode Excitation Voltage | 0.750 VDC |
| Electrode Specifications | Gold cathode Ø4 mm; Silver anode inner Ø5.75 mm, outer Ø12.75 mm |
| Size (W×D×H) | 356 × 190 × 102 mm |
| Current Zero Adjustment | 0–100 nA |
| Current Measurement Gears | 19.99 nA (±10 pA), 199.9 nA (±100 pA), 1.999 μA (±1 nA), 19.99 μA (±10 nA), 199.9 μA (±100 nA) |
Accessories
(1) Electrode assembly frame with two electrode slots.
(2) Gold cathode and silver anode electrodes.
(3) Central thickness gauge for accurate lens measurement.
(4) Constant temperature and humidity chamber.
(5) Calibration and adjustment tools.
(6) User manual and compliance certificates.
Test Procedures
Connect the electrodes to the dual input ports.
Place the lens sample in the electrode assembly frame.
Measure the central thickness of the lens using the thickness gauge.
Set the temperature and humidity to the desired test conditions.
Adjust the electrode excitation voltage to 0.750 VDC.
Zero the current using the current zero adjustment.
Start the polarographic measurement and record the current response.
Calculate the oxygen permeability (Dk) based on the polarographic data.
Repeat for a second sample or electrode if using dual input.
Maintenance Information
(1) Clean electrodes and assembly frame after each test to prevent contamination.
(2) Periodically calibrate the instrument using standard reference lenses.
(3) Check temperature and humidity control systems regularly for accuracy.
(4) Avoid exposure of the instrument to direct sunlight or high humidity.
(5) Replace electrodes when worn or damaged to maintain measurement precision.
(6) Store the instrument in a dry and dust-free environment when not in use.
在线联系供应商
Other supplier products
| Accurate Combustion Threshold Measurement | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Minimum Ignition Temperature Tester is a way of testing the sensitivity o... | |
| ISO Manufacturer of Catheter bending resistance tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Catheter Bending Resistance Tester is a specialized instrument designed t... | |
| Digital Velcro Endurance Tester | Laboratory Testing Equipment Supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features Dual-Roller System: Separate rollers for hook (male) and loop (fema... | |
| UL 94 Vertical Flammability Test Equipment Supplier | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameter: Item Parameter Inner... | |
| Safety Helmet Flammability Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Safety Helmet Flammability Tester is designed to evaluate the flame-retardant performan... |
Same products
| Large Naïve VHH Library | 卖方: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... | |
| EC-98330 电导率营养测试棒 | 卖方: 科立龙电子股份有限公司 | 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0... |