Thermal Protective Performance Tester (TPP)

The Thermal Protective Performance (TPP) Test Device was developed to measure the time elapsed for convective and radiant heat to penetrate through a protective composite fabric system - measuring the resulting damage to human skin. Standards: BS EN ISO 6942. EN 366. EN 407. ISO 11612. ASTM F1939. ASTM F2702. NFPA 1971. NFPA 2112. GB 38543. GB/T 38306 Feature: Industrial personal computer with analysis software is suitable for severe testing conditions. Automatic calculation for heat transmission factor and radiant heat transfer index. Sample holder with force applied kit is easy to operate. Single pump for shutter movement and cooling water loop. TPP Specifications: • Up to 7.5 in x 7.5 in. (19 cm x19 cm) sample size • Copper slug calorimeter sensors (ASTM or ISO) • ± 0.75°C temperature measurement • ± 3% radiant heat flux measurement • Device Dimensions: 42 in. x 20 in. x 18 in. (107 cm x 51 cm x 46 cm) • Space Requirements: 46 in. x 26 in. x 24 in. (117 cm x 67 cm x 61cm) • Power Requirements: 208-265 VAC, 50/60Hz, Single-phase • Maximum nominal current 20 Amps • Compressed Air: Clean/dry air at 70-90 PSI, (145 PSI max) • Cooling Water: Cooling water required, chiller or tap water source is acceptable • Propane Requirement: Regulated supply at 15 PSI (minimum) • Water-cooled radiant heat source with 9 quartz (500W) infrared lamps • Two gas burners with flame detection auto ignition • Mass flow controller for precise gas control • Water-cooled protective shutter • Pneumatic sample carriage and shutter assembly • Integrated sensor cooling stand (air cooled) • Emergency stop cuts gas flow, power to lamps and pneumatics • Tinted tempered glass shield protects operator • Software safety interlocks monitor water flow, carriage position, burner ignition
Other supplier products
|
|
Battery Electrode Resistance Tester |
Standard
ASTM B193: Standard Test Method for Resistivity of Electrical Conductor Materials
ISO 18516: Conductive Coatings – Measurement of ... |
|
|
Helmets Vertical SpacingInfrared - positioning Tester |
Purpose
This measuring instrument is used to measure the vertical spacing and wearing height of safety helmets.
Applicable Standard
GB/T 2812-20... |
|
|
AATCC Viewing Board |
Application
Textile Mills: Assesses surface defects, wrinkles, and seam smoothness post-washing.
Garment Manufacturers: Inspects finished appar... |
|
|
Ross Flex Tester |
Whole Sole ROSS Flexing Tester GT-KB05D To determine right angle flexing risistance for whole sole of rubber, PU, PVC, TPR foam and other materials... |
|
|
" Adiabatic Rate Calorimeter " |
Product Description
Battery Isothermal Calorimeter is a professional instrument developed based on the principle of power compensation isothermal ... |
供应产品
Same products